My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7301 EVERGREEN WAY 2024-05-22
>
Address Records
>
EVERGREEN WAY
>
7301
>
7301 EVERGREEN WAY 2024-05-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2024 7:38:43 AM
Creation date
5/7/2024 10:03:45 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7301
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�v: <br /> HARMSH CFIRE PROTECTION/ <br /> 17 8 <br /> Ash Way,Ste 8 <br /> Lynnwood,WA 98037 <br /> 425-290-9600 <br /> FPISEATTLE.COM <br /> AES RADO D nos I <br /> TYPICAL INSTALLATION DETAIL SHEET INDEX <br /> NFPA <br /> SHEET # SHEET DESCRIPTION 000805173 <br /> FA 0.0 FIRE ALARM : AES INSTALLATION ROY L CATS <br /> QYpOTECl/O <br /> �Q 2 <br /> PROJECT DETAILS <br /> O O ry NFPA S <br /> 1. THE EXISTING BUILDING IS FULLY—SPRINKLED AND HAS AN EXISTING ADDRESSABLE FIRE ALARM CONTROL �`� CFPS <br /> 1 <br /> PANEL(SILENT KNIGHT 5700) LOCATED IN THE SERVICE WAREHOUSE ELECTRICAL AREA. <br /> O O O O O <br /> 2 #1473 <br /> A NEW UL LISTED WIRELESS RADIO COMMUNICATOR (7707-88—ULP) IS BEING INSTALLED AT THE FACE. ALL <br /> ® cw SIGNALS WILL BE TRANSMITTED BY ZONES TO THE UL LISTED SUPERVISING STATION. A 12VDC 12Ah <br /> RR O BATTERY WILL BE INSTALLED IN THE NEW AES RADIO. — <br /> ° <br /> Cl WIRE TO BE IN O 3. THE NEW AES RADIO SHALL TRANSMIT THE EXISTING SYSTEM'S CURRENT REPORTING ZONES. <br /> CONDUIT i <br /> ° u <br /> aE,a - OO OOO OO 4. NO CHANGES TO THE EXISTING SYSTEM WILL BE MADE, NO ADDITIONAL WORK IS INCLUDED IN THIS SCOPE. <br /> w N WO 1w000000 O H V m <br /> U <br /> N <br /> s� PROJECT CONTACT INFO o <br /> B 0 f JFt1� <br /> �g >oOwn< <br /> OWNER FIRE ALARM CONTRACTOR ¢ <br /> ° ° HARNISH CHEVROLET FIRE PROTECTION INC °#m K H o <br /> 7301 EVERGREEN WAY 17410 ASH WAY, Ste 8 m 'w w~ <br /> E,DC 12A EVERETT, WA 98203 LYNNWOOD, WA 98037 z?;1 9 w o <br /> 12VDC 12AIvP CONTACT : WARD FLEISCHMANN CONTACT : DAVID MOW 3 w>a—'o > <br /> PHONE : 425.740.2500 PHONE : 425.290.9600 o z rc H a o <br /> werdf®chevroletofeverett.com devid@fpiseattle.com <br /> AES-7707 RADIO CONMJN[CATOR REVISION RECORD <br /> DATE/DESCRIPTION <br /> CODE INFO <br /> AUTHORITY HAVING JURISDICTION : CITY OF EVERETT <br /> FIRE CODE INTERNATIONAL FIRE CODE, 2018 EDITION <br /> BUILDING USE AND OCCUPANCY : (B) FULLY—SPRINKLED <br /> STANDARDS: 2018 IBC/IFC, 2017 NFPA 70, 2016 NFPA 72, CITY OF EVERETT's STANDARDS <br /> CLASSIFICATION OF SUPERVISING STATION : CENTRAL SUPERVISING STATION <br /> REMOTE SUPERVISING STATION : SECURITAS INC. <br /> PRIME FIRE ALARM CONTRACTOR : FIRE PROTECTION INC <br /> PARCEL NUMBERS : 00393700100303 <br /> INSTALLATION NOTES <br /> EXISTING F1REALARMCONMOLPANNEL, <br /> 1. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. <br /> 2. ALL CIRCUITS MUST BE TESTED FOR OPENS, CONTINUITY, SHORTS, AND GROUNDS. <br /> 3. INSTRUCTIONS FOR THE OPERATING, TESTING AND MAINTENANCE OF THE SYSTEM, ALONG WITH RECORD <br /> DRAWINGS OTHERWISE REFERRED TO AS ("AS—BUILT") AND EQUIPMENT SPECIFICATIONS SHALL BE <br /> PROVIDED TO THE OWNER ONCE THE FIRE ALARM SYSTEM HAS BEEN ACCEPTED BY THE AHJ. . <br /> VICINITYMAP SEQUENCE OF OPERATIONS 4. ALL SYSTEMS AND DEVICES SHALL BE INSTALLED AND TESTED PER THE MANUFACTURES LISTING AND THE <br /> AUTHORITY HAVING JURISDICTION (NFPA72 10.14.2.1). <br /> 5. THE SYSTEM WILL BE 100% PRE—TESTED, AN NFPA 72 COMPLETION FORM WILL BE FILLED OUT AND DATE: 10.30.23 <br /> PROVIDED TO THE AHJ AND THE ELECTRICAL PERMITS MUST BE SIGNED OFF PRIOR TO THE FIRE FINAL PROJECT NAME <br /> SYSTEM OUTPUTS INSPECTION. <br /> Required Fire Safety Control <br /> Central Supervising Stationme 6. THE AES RADIO REQUIRES A DEDICATED 120VAC 20AMP CIRCUIT. A NOTICE PLACED IN THE FACP SHALL <br /> Control Unit Annunciation DIRECT PERSONNEL TO THE LOCATION OF THE ELECTRICAL PANEL THAT IS SUPPLYING DEDICATED POWER <br /> m TO THE SYSTEM (NFPA72, SECTION 10.5.5.1). THE DEDICATED CIRCUIT BREAKER THAT SERVES THE FIRE <br /> .o ALARM SYSTEM SHALL BE LABELED AND SECURED AGAINST TAMPERING WITH A RED BREAKER LOCKOUT <br /> AYSIDE C o <br /> c yo� -o a m� (NFPA72, SECTION 10.5.5.2). <br /> o A ��0°1 ♦� H � <br /> Everett u>s.Rte. `i q y�o°j ® F W Q M <br /> J � N <br /> POR r GARDNE° a w J¢ a'`.c DEVICE INSTALLATION REQUIREMENTS O Z 00 <br /> c' m �=wy JQ yJ¢g`7 0' > LU Q <br /> ,r25., a.o J y , o A W W <br /> 752'q, <br /> FIRE ALARM DEVICE INSTALLATION REQUIREMENTS = w WFabes HO O y yNOT PERMITTED >Mu Iteo Q mo 90CT HERE a• Wi l SUPPORTl ,C OBRACKET DIFF°SER rZV LLIddd7301 EVERGREEN WAY mdmm m /mU M WEVERETT,WA 98203 4moJq oJq PcwaecgPcwPcwFA DEVICE DETECTOR MINIMUMSMOKE® AWAY FROM NOT PERMITTED SYSTEMINPUTS B D F H HVAC DIFFUSERS HERE IManual Fire Alarm Pull-Station ♦ ♦♦ 1 H SSMOKECASCADE VIEW 2 Smoke Detectors ♦ ♦♦ 2F3 Wet l Dry Flow ♦ ♦♦♦ 3 - SHEET TITLE <br /> 4 Unused 4 MI99 NXHEGHrr82"AFF` RG 3 FIRE ALARM <br /> fL 5 Sprinkler Tamper)PIV ♦ ♦ 5 IllA AES RADIO <br /> _. _ _ Eastmontul 6 Unused 6 �_ COMMUNICATOR <br /> 7 Fire Alarm AC Power Failure ♦ ♦ JH <br /> O — INSTALLATION <br /> SILVER LAKE J 66"A.F.F 60"A.F.FNot to Scale M 8 Fire Alarm System Low Battery 8 Open Circuit ♦ ♦ ae•AFF SHEET NUMBER <br /> 10 Ground Fault ♦ ♦A B C D E F G -I I <br /> FA 0.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.