Laserfiche WebLink
Permit#: FA2311-001 <br /> EVERETT Site Address: 11225 19th Ave SE BLDG-A <br /> Everett Fire Dept.Permit Review Applicant: Brimstone Fire Safety MNG LLC <br /> Richard S.Gehlhausen Status:Approved Application Date: 11/07/2023 <br /> Reviewed By:KBrown Description: Building A-Fire Panel Replacement <br /> NICET Certification No.140592 11/15/2023 3:40:45 Review Date: 11/15/2023 <br /> Fire Protection Engineering Technology PM <br /> Fire Alarm Systems-Level III <br /> Certification Expires: August 1,2024 GENERAL NOTES: UNLESS OTHERWISE SPECIFIED <br /> ARTESIA APARTMENTS, BUILDING A 1. APPLICABLE CODES: <br /> INTERNATIONAL FIRE CODE, 2015 EDITION WITH <br /> 11225 19th Ave SE, Everett, WA 98208 STANDARDS & AMENDMENTS - WAC 51-54A <br /> DEVICE ELEVATION DETAIL WASHINGTON STATE FIRE CODE, 2015 EDITION <br /> 6" MIN. 6" MIN. CHAPTER 9 <br /> FINISHED CEILING NFPA 72, NATIONAL FIRE ALARM CODE, 2016 EDITION <br /> NATIONAL ELECTRICAL CODE, EDITION 2017 <br /> VISUAL HORN CHIME HORN NATIONAL BUILDING CODE, EDITION 2015 <br /> STROBE STROBE STROBE SCOPE OF WORK: <br /> SZ TO REPLACE THE EXISTING FIRE ALARM SYSTEM WITH A NEW POTTER 4064 FIRE ALARM PANEL AND A NEW AES 2. WITNESS OF FINAL FIRE ALARM TEST BY LOCAL FIRE <br /> u RADIO TRANSMITTER.THIS INCLUDES A NEW NEMA4 ENCLOSURE,SMOKE DETECTOR,MAUAL STATION,AND HEATER. AUTHORITY AND PROJECT INSPECTOR. <br /> 3. WIRE TYPE & SIZE: <br /> FACP A = 16/2 SOLID, TYPE FPLP FOR INITIATING CIRCUITS <br /> oaeRneLe SYSTEM DESCRIPTION: 4. UNDERGROUND AND EXTERIOR CONDUITS TO HAVE <br /> ANN PULL 80" MIN. THIS IS A MANUAL/AUTOMATIC FIRE ALARM SYSTEM, WATER-TIGHT FITTINGS AND WIRES TO BE APPROVED <br /> 72" MANUAL 96" MAX. 90" MIN. WITH A CONVENTIONAL CONTROL PANEL AND INITIATING FOR WET LOCATIONS. <br /> STATION DEVICES, WIRED STYLE 4 (CLASS B). <br /> 60" 48" 5. AUDIBLE SIGNALS SHALL BE AT LEAST 15dBA ABOVE <br /> AVERAGE AMBIENT SOUND LEVEL BUT NOT LESS THAN <br /> 75dBA AT 10FT. OR MORE THAN 120dBA AT THE <br /> MINIMUM HEARING DISTANCE FROM THE DEVICE. <br /> 6. AUDIBLE DEVICES SHALL SOUND A TEMPORAL 3 PATTERN. <br /> FINISHED FLOOR 7. VISUAL DEVICE SHOULD NOT EXCEED (2) FLASHES PER <br /> SECOND & SHOULD NOT BE SLOWER THAN (1) FLASH <br /> EVERY SECOND. <br /> 8. ALL VISUAL DEVICES SHALL FLASH IN SYNCHRONIZATION. <br /> FIRE ALARM SYSTEM SEQUENCE OF OPERATION 9. FIRE ALARM CONTRACTOR SHALL PROVIDE A RECORD <br /> OF COMPLETION TO THE INSPECTOR OF RECORD AFTER <br /> FACP FACP FACP OFF SITE OFF SITE OFF SITE COMPLETION OF OPERATIONAL ACCEPTANCE TESTS. N <br /> ALARM TRBL SUPV ALARM TRBL SUPV <br /> SMOKE DETECTOR @ FACP X X <br /> MANUAL STATION 0 FACP X X W E <br /> INITIATING CIRCUIT <br /> STYLE 4 (CLASS B) <br /> THROUGH PENETRATION DETAIL PER U.L.*W-L-1323 OPEN WIRE X X <br /> SYSTEM NO.W-L-1323 GROUNDED WIRE X X cu ■ S <br /> F RATING-2 HR. SHORTED WIRES X X < m v <br /> REVISIONS <br /> T RATINGS-l 1/4&2 HR.(SEE ITEM 2) NOTIFICATION CIRCUIT a ¢ _ <br /> STYLE 4 (CLASS B) <br /> OPEN WIRE X X � m I�I� <br /> A GROUNDED WIRE X X < S om 10 _ <br /> 3B 3A SHORTED WIRES X X <br /> U <br /> SIGNAL LINE CIRCUIT X <br /> ma <br /> _____ STYLE 4 (CLASS B) m <br /> -__-___ OPEN WIRE X X ^^ - <br /> __ 2 GROUNDED WIRE X X lop <br /> 1B WIRE TO WIRE SHORT/OPEN X X �I I{� �I �I I*1� I� I� -■ m n <br /> WIRE TO WIRE SHORT/GND X X p ©:00 Iit�11W� ■YIDYi�W rawing I te: <br /> A OPEN & GROUND X X _ <br /> COVER SHEET <br /> D (x <br /> 1A LOSS OF CARRIER X X X {M,:{ '� © c Project No. <br /> SECTION A-A Drawn By: R.GEHLHAUSEN <br /> 1. WALL ASSEMBLY - THE 2 HR FIRE RATED GYPSUM BOARD/STUD WALL ASSEMBLY D <br /> SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED - K3 - Scale: None <br /> IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS IN611 <br /> THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING = Date: 11/07/2023 <br /> CONSTRUCTION FEATURES. <br /> A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL 190 DWG Type: FIRE ALARM PLAN <br /> CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER - �* ■ 00800083 MCC-0032 u0�F3r7© <br /> SPACED 16 IN. OC. STEEL STUDS TO BE MIN 3-1/2 IN. WIDE AND SPACED <br /> MAX. 24 IN. OC. spa <br /> B. GYPSUM BOARD * - TWO LAYERS OF NOM 5/8 IN. THICK GYPSUM BOARD, AS WIRELESS COMMUNICATOR SEQUENCE OF OPERATION 01010010 <br /> SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DAM OF Q <br /> OPENING IS 12-3/4 IN. <br /> COMMUN. COMMUN. COMMUN. OFF SITE OFF SITE OFF SITE Ur <br /> `;/.' J <br /> 2. THROUGH PENETRANT - ONE METALLIC PIPE OR TUBING INSTALLED CONCENTRICALLY ALARM TRBL SUPV ALARM TRBL SUPV is s` z pD J M <br /> OR ECCENTRICALLY WITHIN OPENING. ANNULAR SPACE BETWEEN PENETRANT AND SMOKE DETECTOR ® FACP X X ON Q <br /> PERIPHARY OF OPENING SHALL BE MIN OF 0 IN. (POINT CONTACT) TO MAX 2 IN. --_ 00 3 <br /> PENETRANT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE MANUAL STATION ® FACP X X <br /> FOLLOWING TYPES AND SIZES OF PENETRANTS MAY BE USED: E0 Q O d <br /> INITIATING CIRCUIT m <br /> < r _ <br /> A. STEEL PIPE - NOM 10 IN. DAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) <br /> STEEL PIPE. (CLASS B) _ 4 C J <br /> OPEN WIRE X X (n N C".E m <br /> B. IRON PIPE - NOM 10 IN. DAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. GROUNDED WIRE X X j- 0) 0 O <br /> C. COPPER TUBING - NOM 4 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) SHORTED WIRES X X z w = 0 W <br /> COPPER TUBING. LLQ IQ I.I. <br /> D. COPPER PIPE - NOM 4 IN. DAM (OR SMALLER) REGULAR (OR HEAVIER) NOTIFICATION CIRCUIT LLJ W U) <br /> COPPER PIPE. (CLASS B) SYMBOLS LEGEND F- 0 rn ¢ <br /> THE HOURLY T RATING IS 2 HR FOR PENETRANTS A AND B. THE HOURLY RATING OPEN WIRE X X > <br /> IS 1-1/4 HR FOR PENETRANTS C AND D. GROUNDED WIRE X X QTY. SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX 1 Q W <br /> 3. FIRESTOP SYSTEM - THE DETAILS OF THE FIRESTOP SYSTEM SHALL BE AS FOLLOWS: SHORTED WIRES X X Q \ +L+ 41, <br /> 1 FACP FIRE ALARM CONTROL PANEL AFC-4064 POTTER PROVIDED n <br /> A. FILL, VOID OR CAVITY MATERIALS * - CAULK, SEALANT OR PUTTY - MIN 5/8 IN. SIGNAL LINE CIRCUIT Q H N N <br /> THICKNESS OF CAULK, SEALANT OR PUTTY APPLIED WITHIN THE ANNULUS, FLUSH N N C <br /> WITH BOTH SURFACES OF WALL. (CLASS B) 1 AES RADIO ALARM TRANSMITTER 7707P-88-ULP-M AES PROVIDED L� L 7 d <br /> N D <br /> 3M COMPANY - CP 25W8+ CAULK, FB-3000 WT SEALANT, MP+ STIX PUTTY. OPEN WIRE X X I.- <br /> GROUNDED WIRE X X � � N J <br /> B. DUCT WRAP MATERIAL * - NOM 2 IN. THICK DUCT WRAP TIGHTLY WRAPPED 1 O2 PHOTO SMOKE DETECTOR 2-WB SYSTEM SENSOR 4SQ.DEEP <br /> AROUND PENETRANT, BUTTED TO WALL AND EXTENDING 24 IN. BEYOND BOTH WIRE TO WIRE SHORT/OPEN X X WNGRING Q <br /> SURFACES OF WALL. LONGITUDINAL SEAMS SEALED WITH FOIL TAPE. WIRE TO WIRE SHORT/GND X X MANUAL PULLK 4SQ.DEEP <br /> 3M COMPANY - FIRE BARRIER DUCT WRAP 20A. OPEN & GROUND X X 1 e STATION -270 KIDDE WNGRING <br /> * BEARING THE UL CLASSIFICATION MARKING LOSS OF CARRIER X X END OF LINE DEVICE N/A SHEET <br /> 4.7K,112W <br /> IN AFF=ABOVE FINISHED FLOOR,F.B.O=FURNISHED BY OTHERS,N/A NOT APPLICABLE FA-01 <br />