Laserfiche WebLink
L Permit#: FA2311-002 <br /> EVERETT Site Address: 1122519th Ave SE <br /> Richard S.GehlhauSen Everett Fire Dept.Permit Review Applicant: Brimstone Fire Safety MNG LLC <br /> Status:Approved Application Date: 11/08/2023 <br /> NICET Certification No.140592 Description: Building N-Fire Panel Replacement <br /> Fire Protection Engineering Technology Reviewed By:KBrown Review Date: 11/15/2023 <br /> 11/15/2023 3:46:32 <br /> Fire Alarm Systems-Level III PM <br /> Certification Expires: August 1,2024 GENERAL NOTES: UNLESS OTHERWISE SPECIFIED <br /> ARTESIA APARTMENTS, BUILDING J 1. APPLICABLE CODES: <br /> INTERNATIONAL FIRE CODE, 2015 EDITION WITH <br /> 11225 19th Ave SE, Everett, WA 98208 STANDARDS & AMENDMENTS — WAC 51-54A <br /> DEVICE ELEVATION DETAIL WASHINGTON STATE FIRE CODE, 2015 EDITION <br /> 6" MIN. 6" MIN. CHAPTER 9 <br /> FINISHED CEILING NFPA 72, NATIONAL FIRE ALARM CODE, 2016 EDITION <br /> NATIONAL ELECTRICAL CODE, EDITION 2017 <br /> VISUAL HORN CHIME HORN NATIONAL BUILDING CODE, EDITION 2015 <br /> STROBE STROBE STROBE SCOPE OF WORK: <br /> SZ TO REPLACE THE EXISTING FIRE ALARM SYSTEM WITH A NEW POTTER 4064 FIRE ALARM PANEL AND A NEW AES 2. WITNESS OF FINAL FIRE ALARM TEST BY LOCAL FIRE <br /> u RADIO TRANSMITTER.THIS INCLUDES A NEW NEMA4 ENCLOSURE,SMOKE DETECTOR,MAUAL STATION,AND HEATER. AUTHORITY AND PROJECT INSPECTOR. <br /> 3. WIRE TYPE & SIZE: <br /> FACP A = 16/2 SOLID, TYPE FPLP FOR INITIATING CIRCUITS <br /> oPeRneLe SYSTEM DESCRIPTION: 4. UNDERGROUND AND EXTERIOR CONDUITS TO HAVE <br /> ANN PULL 80" MIN. THIS IS A MANUAL/AUTOMATIC FIRE ALARM SYSTEM, WATER—TIGHT FITTINGS AND WIRES TO BE APPROVED <br /> 72" MANUAL 96" MAX. 90" MIN. WITH A CONVENTIONAL CONTROL PANEL AND INITIATING FOR WET LOCATIONS. <br /> STATION DEVICES, WIRED STYLE 4 (CLASS B). <br /> 60" 48" 5. AUDIBLE SIGNALS SHALL BE AT LEAST 15dBA ABOVE <br /> AVERAGE AMBIENT SOUND LEVEL BUT NOT LESS THAN <br /> 75dBA AT 10FT. OR MORE THAN 120dBA AT THE <br /> MINIMUM HEARING DISTANCE FROM THE DEVICE. <br /> 6. AUDIBLE DEVICES SHALL SOUND A TEMPORAL 3 PATTERN. <br /> FINISHED FLOOR 7. VISUAL DEVICE SHOULD NOT EXCEED (2) FLASHES PER <br /> SECOND & SHOULD NOT BE SLOWER THAN (1) FLASH <br /> EVERY SECOND. <br /> 8. ALL VISUAL DEVICES SHALL FLASH IN SYNCHRONIZATION. <br /> FIRE ALARM SYSTEM SEQUENCE OF OPERATION 9. FIRE ALARM CONTRACTOR SHALL PROVIDE A RECORD <br /> OF COMPLETION TO THE INSPECTOR OF RECORD AFTER <br /> FACP FACP FACP OFF SITE OFF SITE OFF SITE COMPLETION OF OPERATIONAL ACCEPTANCE TESTS. N <br /> ALARM TRBL SUPV ALARM TRBL SUPV <br /> SMOKE DETECTOR @ FACP X X <br /> MANUAL STATION 0 FACP X X W E <br /> INITIATING CIRCUIT <br /> STYLE 4 (CLASS B) <br /> THROUGH PENETRATION DETAIL PER U.L.*W-L-1323 OPEN WIRE X X <br /> SYSTEM NO.W-L-1323 GROUNDED WIRE X X cu ■ S <br /> F RATING-2 HR. SHORTED WIRES X X < m v <br /> REVISIONS <br /> T RATINGS-11/4&2 HR.(SEE ITEM 2) NOTIFICATION CIRCUIT a ¢ _ <br /> STYLE 4 (CLASS B) <br /> OPEN WIRE X X � m I�I� <br /> A GROUNDED WIRE X X < S om 10 _ <br /> 3B 3A SHORTED WIRES X X <br /> U <br /> SIGNAL LINE CIRCUIT X <br /> ma <br /> _____ STYLE 4 (CLASS B) �� rows <br /> 0 <br /> -____ OPEN WIRE X X ^ - <br /> __ 2 GROUNDED WIRE X X lop <br /> 1B WIRE TO WIRE SHORT/OPEN X X �rI I{� �I �I I*1� I� I� -■ m n <br /> WIRE TO WIRE SHORT/GND X X ©�ICW9� Ii��t�11W� ■YIDYi�W rawmg It e: <br /> A OPEN & GROUND X X <br /> COVER SHEET <br /> 00 <br /> D (x <br /> 1A LOSS OF CARRIER X X X {M,:{ © c Project No. <br /> SECTION A-A Drawn By: R.GEHLHAUSEN <br /> Jou <br /> 1. WALL ASSEMBLY - THE 2 HR FIRE RATED GYPSUM BOARD/STUD WALL ASSEMBLY <br /> SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED - = Scale: None <br /> IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS IN <br /> THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING t- ML Date: 11/07/2023 <br /> CONSTRUCTION FEATURES. is loom <br /> 17/� _ j/[ <br /> A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL p DWG Type: FIRE ALARM PLAN <br /> CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER - ■ 00800083 MCC-0032 200013 <br /> SPACED 16 IN. OC. STEEL STUDS TO BE MIN 3-1/2 IN. WIDE AND SPACED <br /> MAX. 24 IN. OC. <br /> B. GYPSUM BOARD * - TWO LAYERS OF NOM 5/8 IN. THICK GYPSUM BOARD, AS WIRELESS COMMUNICATOR SEQUENCE OF OPERATION 01010010 01000010 Fi©0um <br /> SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM OF <br /> OPENING IS 12-3/4 IN. `;/.' <br /> COMMUN. COMMUN. COMMUN. OFF SITE OFF SITE OFF SITE � 0 J n <br /> 2. THROUGH PENETRANT - ONE METALLIC PIPE OR TUBING INSTALLED CONCENTRICALLY ALARM TRBL SUPV ALARM TRBL SUPV z 00 J M <br /> OR ECCENTRICALLY WITHIN OPENING. ANNULAR SPACE BETWEEN PENETRANT AND <br /> SMOKE DETECTOR ® FACP X X Q ON y"� Q <br /> PERIPHARY OF OPENING SHALL BE MIN OF 0 IN. (POINT CONTACT) TO MAX 2 IN. 00 <br /> PENETRANT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE MANUAL STATION ® FACP X X �- J 01 3 <br /> FOLLOWING TYPES AND SIZES OF PENETRANTS MAY BE USED: co Q d <br /> INITIATING CIRCUIT m < r _ <br /> A. STEEL PIPE - NOM 10 IN. DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) <br /> STEEL PIPE. (CLASS B) _ C J <br /> OPEN WIRE X X U) N C"'y N <br /> 10 <br /> B. IRON PIPE - NOM 10 IN. DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE. <br /> GROUNDED WIRE X X 0) 44 cc 0 O <br /> C. COPPER TUBING - NOM 4 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) SHORTED WIRES X X Lij LL y = 3 W <br /> COPPER TUBING. IQ LL <br /> D. COPPER PIPE - NOM 4 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) NOTIFICATION CIRCUIT L N U) <br /> COPPER PIPE. (CLASS B) SYMBOLS LEGEND <br /> THE HOURLY T RATING IS 2 HR FOR PENETRANTS A AND B. THE HOURLY RATING <br /> OPEN WIRE X X > <br /> IS 1-1/4 HR FOR PENETRANTS C AND D. GROUNDED WIRE X X QTY. SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX a %lim 1\ Q W <br /> L <br /> 3. FIRESTOP SYSTEM - THE DETAILS OF THE FIRESTOP SYSTEM SHALL BE AS FOLLOWS: SHORTED WIRES X X 1 FACP Q FIRE ALARM CONTROL PANEL AFC-4064 POTTER PROVIDED � Cc n 4t <br /> A. FILL, VOID OR CAVITY MATERIALS * - CAULK, SEALANT OR PUTTY - MIN 5/8 IN. Q H N N <br /> SIGNAL LINE CIRCUIT <br /> THICKNESS OF CAULK, SEALANT OR PUTTY APPLIED WITHIN THE ANNULUS, FLUSH (CLASS B) N N = <br /> WITH BOTH SURFACES OF WALL. 1 AES RADIO ALARM TRANSMITTER 7707P-88-ULP-M AES PROVIDED LL! L 7 <br /> OPEN WIRE X X ILL N J <br /> 3M COMPANY - CP 25WB+ CAULK, FB-3000 WT SEALANT, MP+ STIX PUTTY. <br /> B. DUCT WRAP MATERIAL * - NOM 2 IN. THICK DUCT WRAP TIGHTLY WRAPPED GROUNDED WIRE X X 1 O2 PHOTO SMOKE DETECTOR 2-WB SYSTEM SENSOR 4SQ.DEEP <br /> AROUND PENETRANT, BUTTED TO WALL AND EXTENDING 24 IN. BEYOND BOTH WIRE TO WIRE SHORT/OPEN X X WNGRING Q VVI <br /> SURFACES OF WALL. LONGITUDINAL SEAMS SEALED WITH FOIL TAPE. WIRE TO WIRE SHORT/GND X X MANUAL PULLK 4SQ.DEEP <br /> 3M COMPANY - FIRE BARRIER DUCT WRAP 20A. OPEN & GROUND X X 1 STATION -270 KIDDE WNGRING <br /> * BEARING THE UL CLASSIFICATION MARKING LOSS OF CARRIER X X END OF LINE DEVICE N/A SHEET <br /> 4.7K,1/2W <br /> AFF=ABOVE FINISHED FLOOR,F.B.O=FURNISHED BY OTHERS,N/A NOT APPLICABLE FA-0 1 <br />