My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5130 EVERGREEN WAY COMMUNITY MEDICAL SERVICES 2025-05-09
>
Address Records
>
EVERGREEN WAY
>
5130
>
COMMUNITY MEDICAL SERVICES
>
5130 EVERGREEN WAY COMMUNITY MEDICAL SERVICES 2025-05-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2025 9:35:43 AM
Creation date
5/7/2024 11:31:44 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5130
Tenant Name
COMMUNITY MEDICAL SERVICES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
258
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • Project Title: <br /> Engineer: <br /> Project ID: <br /> Project Descr: <br /> Wood Beam Project File:cms everett.ec6 <br /> LIC#:KW-06014122,Build:20.23.04.05 PCS STRUCTURAL SOLUTIONS (c)ENERCALC INC 1983-2023 <br /> DESCRIPTION: Roof Top Unit Platform <br /> CODE REFERENCES <br /> Calculations per NDS 2018, IBC 2018, CBC 2019,ASCE 7-16 <br /> Load Combination Set: IBC 2021 <br /> Material Properties <br /> Analysis Method : Allowable Stress Design Fb+ 900 psi E:Modulus of Elasticity <br /> Load Combination IBC 2021 Fb- 900 psi Ebend-xx 1600 ksi <br /> Fc-PrIl 1350 psi Eminbend-xx 580 ksi <br /> Wood Species : Douglas Fir-Larch Fc-Perp 625 psi <br /> Wood Grade : No.2 Fv 180 psi <br /> Ft 575 psi Density 31.21 pcf <br /> Beam Bracing : Beam is Fully Braced against lateral-torsional buckling <br /> Dt0.1) <br /> D(0.02)S(0.05) <br /> 2x8 <br /> Span=8.0ft <br /> Applied Loads Service loads entered.Load Factors will be applied for calculations. <br /> Beam self weight calculated and added to loading <br /> Uniform Load : D =0.010, S =0.0250 ksf, Tributary Width = 2.0 ft <br /> Point Load : D = 0.10 k @ 4.0 ft, (Mechanical Unit) <br /> DESIGN SUMMARY Design OK <br /> Maximum Bending Stress Ratio = 0.573 1 Maximum Shear Stress Ratio = 0.198 : 1 <br /> Section used for this span 2x8 Section used for this span 2x8 <br /> fb:Actual = 711.25 psi fv:Actual = 40.99 psi <br /> F'b = 1,242.00 psi F'v = 207.00 psi <br /> Load Combination +D+S Load Combination +D+S <br /> Location of maximum on span = 4.000ft Location of maximum on span = 7.416 ft <br /> Span#where maximum occurs = Span#1 Span#where maximum occurs = Span# 1 <br /> Maximum Deflection <br /> Max Downward Transient Deflection 0.061 in Ratio= 1578>=360 Span: 1 : S Only <br /> Max Upward Transient Deflection 0 in Ratio= 0<360 n/a <br /> Max Downward Total Deflection 0.112 in Ratio= 854>=240 Span: 1 : +D+S <br /> Max Upward Total Deflection 0 in Ratio= 0<240 n/a <br /> Maximum Forces &Stresses for Load Combinations <br /> Load Combination Max Stress Ratios Moment Values Shear Values <br /> Segment Length Span# M V CD CM Ct CLx CF Cfu C Cr M fb F'b V fv F'v <br /> D Only 0.0 0.00 0.0 0.0 <br /> Length=8.0 ft 1 0.356 0.108 0.90 1.00 1.00 1.00 1.200 1.00 1.00 1.00 0.38 346.0 972.0 0.13 17.4 162.0 <br /> +D+S 1.00 1.00 1.00 1.200 1.00 1.00 1.00 0.0 0.00 0.0 0.0 <br /> Length=8.0 ft 1 0.573 0.198 1.15 1.00 1.00 1.00 1.200 1.00 1.00 1.00 0.78 711.3 1,242.0 0.30 41.0 207.0 <br /> +D+0.750S 1.00 1.00 1.00 1.200 1.00 1.00 1.00 0.0 0.00 0.0 0.0 <br /> Length=8.0 ft 1 0.499 0.170 1.15 1.00 1.00 1.00 1.200 1.00 1.00 1.00 0.68 619.9 1,242.0 0.25 35.1 207.0 <br /> +0.60D 1.00 1.00 1.00 1.200 1.00 1.00 1.00 0.0 0.00 0.0 0.0 <br /> Length=8.0 ft 1 0.120 0.036 1.60 1.00 1.00 1.00 1.200 1.00 1.00 1.00 0.23 207.6 1,728.0 0.08 10.5 288.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.