My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6605 MERRILL CREEK PKY 2024-05-23
>
Address Records
>
MERRILL CREEK PKY
>
6605
>
6605 MERRILL CREEK PKY 2024-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2024 7:32:47 AM
Creation date
5/8/2024 10:36:17 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
6605
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEQUENCE OF OPERATION i <br /> �E <br /> � c) <br /> HUMIDIFIER(HUM) z <br /> CONTROL TYPE:FACTORY CONTROLS.BMS IS USED FOR STATUS VISIBILITY ONLY,NOT DIRECT CONTROL. C Q 3 E <br /> OCCUPIED HOURS:24!//385 C L m E <br /> DESCRIPTION:ROOF MOUNTED GAS FIRED HUMIDIFIER,OUTDOOR ENCLOSURE,FACTORY CONTROLS WITH MODBUS AND SACHET. <br /> CONFIGURATION:(2)HUMIDIFIERS IN A N-I CONFIGURATION SUPPLY A SINGLE MUA UNIT. - <br /> 8 SENSORS:CONNECT FACTORY CONTROLS TO EXISTING SENSORS(ZONE HUMIDISTAT,POSITIVE AIRFLOW SENSOR,HIGH-LIMIT HUMIDISTAT) co -� <br /> GENERAL OPERATION: °)v <br /> 3 FACTORY CONTROLS RECEIVES AN INPUT FROM THE EXISTING ZONE HUMIDISTAT TO CONTROL THE STEAM OUTPUT. 0 } N <br /> HUMIDIFIER FILL AND FLUSH ARE AUTOMATICALLY CONTROLLED BY FACTORY CONTROLS. 0 -on <br /> 8 OUTDOOR ENCLOSURE COOLING FANS AND FREEZE PROTECTION ARE AUTOMATICALLY CONTROLLED BY FACTORY CONTROLS. � - mo <br /> SAFETY INTERLOCKS:HUMIDIFIER ONLY OPERATES UPON AIRFLOW SENSED BY THE POSITIVE AIRFLOW SENSOR.HUMIDIFIER SHUT$OFF UPON ASIGNAL FROM THE HIGH-LIMIT HUMIDISTAT. U <br /> ISOLATION VALVES:AN ISOLATION VALVE IS INSTALLED IN THE STEAM SUPPLY PIPE FROM EACH HUMIDIFIER TO THE$TEAM INLET ADAPTER.THE VALVE FOR THE PRIMARY HUMIDIFIER MUST co < c- <br /> LL <br /> E ALWAYSBEOPEN.THE VALVE FOR THE STANDBY HUMIDIFIER MUST ALWAYS BE CLOSED.VALVES FOR THE PRIMARY AND STANDBY HUMIDIFIERS SHOULD NEVER BE BOTH OPEN OR BOTH CLOSED. G �a <br /> G <br /> SETPOINTS <br /> 4 <br /> ZONE HUMIDITY SETPOINT:35%RH(ADJ.) <br /> i HIGHIIMIT HUMIDISTAT:85%RH(ADJ.) <br /> BMS POINTS <br /> _ THE BACNET POINTS LISTED BELOW ARE SUGGESTED POINTS.VERIFY THE REQUIRED POINTS WITH THE BUILDING ENGINEER AND OWNER. F _� <br /> REFER TO THE HUMIDIFIER IOM FOR A FULL LIST OF BACNET POINTS. <br /> -HUM STATUS,OPERATING STATUS <br /> -SERVICE STATUS,MAINTENANCE AND MALFUNCTIONS STATUS 819' <br /> -FAULT CODE,ERROR CODE BBIOXeL`� <br /> -HUMIDITY CONTROL,HUMIDITY DEMAND 0-100% <br /> -SETPOINT,HUMIDITY$ETPOINT 0-55% <br /> -LEVEL,WATER LEVEL IN TUB <br /> DATATRENDING 08/18/2023 <br /> THE TREND POINTS AND TIME INTERVALS LISTED BELOW ARE SUGGESTED.VERIFY THE REQUIRED TREND POINTS AND TIME INTERVALS WITH THE BUILDING ENGINEER AND OWNER, <br /> AMOUNT OF TREND DATA TO RECORD:3 MONTHS <br /> -ZONE HUMIDITY,EVERY 30 MINUTES <br /> w <br /> -ZONE TEMPERATURE,EVERY 30 MINUTES Q <br /> -ZONE HUMIDITY SET POINT,EVERY 30 MINUTES ❑ <br /> -OUTDOOR AIR TEMPERATURE,EVERY 30 MINUTES <br /> -OUTDOOR AIR RELATIVE HUMIDITY,EVERY 30 MINUTES <br /> -HUMIDITY CONTROL,HUMIDITY DEMAND 0-100%,EVERY 30 MINUTES <br /> PIPING SYSTEM ABBREVIATIONS <br /> 0 <br /> ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME w <br /> C CONDENSATE INDIRECT DRAIN HHWR HEATING HOT WATER RETURN NOV NATURAL GAS VENT W <br /> CA AIR COMPRESSED HHWS HEATING HOT WATER SUPPLY PA AIR PNEUMATIC I K <br /> CDWR CONDENSER WATER RETURN HPC STEAM CONDENSATE HIGH PRESS PC CONDENSATE PUMPED <br /> CDWS CONDENSER WATER SUPPLY HPS STEAM HIGH PRESS PCHR CHILLED WATER(PROCESS)RETURN <br /> CHRV CHILLER RELIEF VENT HRR HEAT RECOVERY RETURN PCHS CHILLED WATER(PROCESS)SUPPLY I w <br /> CHWR CHILLED WATER RETURN HRS HEAT RECOVERY SUPPLY RGAS REFRIGERANT HOT GAS F <br /> CHWS CHILLED WATER SUPPLY LPC STEAM CONDENSATE LOW PRESS RLIQ REFRIGERANT LIQUID <br /> C STM STEAM CLEAN LPG LIQUID PROPANE RSUC REFRIGERANT SUCTION <br /> C CLOSED LOOP WATER RETURN LIPS STEAM LOW PRESS SCHR CHILLED WATER(SECONDARY)RETURN <br /> CLS CLOSED LOOP WATER SUPPLY LTCR CHILLED WATER(LOW TEMP)RETURN SCHS CHILLED WATER(SECONDARY)SUPPLY <br /> COMB-PVC AIR COMBUSTION PVC LTCS CHILLED WATER(LOW TEMP)SUPPLY SCV STEAM CONDENSATE VENT <br /> CRYV CRYO VENT MPC STEAM CONDENSATE MEDIUM PRESS SPC STEAM CONDENSATE PUMPED <br /> FOC FUEL OIL SECONDARY CONTAINMENT MPS STEAM MEDIUM PRESS 5V STEAM VENT <br /> F FUEL OIL FILL MUW MAKE-UP WATER VAC VACUUM <br /> FOR FUEL OIL RETURN NG-2PSI NATURAL GAS 2PSI VAC-E VACUUM EXHAUST <br /> FOS FUEL OIL SUPPLY NC-5PSI NATURAL GAS 5PSI VRFG VRF HOT GAS <br /> FOV FUEL OIL VENTS NG-CONDUIT NATURAL GAS CONDUIT VRFL VRF HIGH PRESS LIQUID <br /> GENX GENERATOR EXHAUST NG-H NATURAL GAS HIGH PRESS VRFS VRF LOW PRESS SUCTION <br /> G GLYCOL WATER RETURN NGL NATURAL GAS LOW PRESS <br /> GLWS GLYCOL WATER SUPPLY NG-M NATURAL GAS MEDIUM PRESS N <br /> 0 <br /> O <br /> w <br /> PIPING SYMBOL LEGEND J <br /> SYMBOL DESCRIPTION ABBV SYMBOL DESCRIPTION ABBV LL] <br /> VALVE TWO-WAY CONTROL 2WAY Q SENSOR SNSR N <br /> VALVE THREE-WAY CONTROL SWAY Q TEMPERATURE INDICATOR THERM <br /> VALVE AUTOMATIC FLOW CONTROL AF METER BTU BTU MTR <br /> 0 VALVE BALANCING BALV SUB-METER WATER FLOW MTR Uj <br /> VALVE BALANCING AUTOMATIC ABALV PRESSURE/TEMPERATURE PORT P&T LL. <br /> Pa VALVE BALL-FULL PORTED BV DP SENSOR PRESSURE DIFFERENTIAL DP Q <br /> VALVE BALL-W/3/4"HOSE ADAPTOR BVW/HA STRAINER STRN CC <br /> QI VALVE BUTTERFLY BFV SUCTION DIFFUSER SUC DIFF C <br /> QI VALVE BUTTERFLY-W/MEMORY STOP BFVM = UNION UNION T� <br /> N VALVE CHECK CV HOSE BIBB HE 2 w <br /> TiT VALVE CIRCUIT SETTER CS 'L PIPE BREAK-PIGTAIL I U <br /> VALVE GAS COCK GC POINT OF CONNECTION P.O.C. <br /> UZ} <br /> DQ VALVE GATE GV I> CONCENTRIC REDUCER CR I„LI Q <br /> VALVE GLOBE GLV ECCENTRIC REDUCER ER z_ /1 <br /> VALVE PRESSURE REDUCING PRV acrvws PIPE-SIZE&ABBREVIATION <br /> 0U) <br /> UJ/� <br /> V <br /> Qa ! <br /> VALVE PRESSURE RELIEF RV 6'CHws PIPE-SIZE&ABBREVIATION WITH INSULATION <Y <br /> LEI <br /> VALVE SOLENOID SV THERMAL EXPANSION DEVICE EXP LL LUN J U ♦wj <br /> Q AUTOMATIC AIR VENT AV FLI FLEXIBLE CONNECTION O J(..) v/ <br /> MANUALAIRVENT MAV 4 FLEX PIPE I <J <br /> WATER HAMMER ARRESTOR WHA PIPE-HEAT TRACEMJM co <br /> W <br /> W-1BACKFLOW PREVENTER BFP ® PUMP W Wo�I j / <br /> ® RREDBUCCEE PRESS.BACKFLOW PREVENTER BW P AIR SEPARATOR <br /> POT FEEDER C OTEP ♦Z/���Z/�-W X0�/�= /w/� <br /> V)U).W U) o- <br /> C FLOW DIRECTION ARROW HEAT EXCHANGER HTX _ <br /> Q PRESSURE INDICATOR PRESS EXPANSION TANK ET C LEE 08-0823 <br /> CHECKED BY DATE P-D <br /> S HARGROVE 08.08-23 <br /> CAD ISSUE DATE <br /> D LAMBERT 08-08-23 <br /> RABING NUMBER <br /> DC-2710-73234418-00 <br /> SHEET NUMBER <br /> TM0.02 <br /> L City of Everett Permit Review <br /> EVERETT Status:Approved <br /> 09/12/2023 8:59:20 AM <br /> L <br />
The URL can be used to link to this page
Your browser does not support the video tag.