Laserfiche WebLink
NOTES <br /> I THE (2) CONDUITS WITH (4) CURRENT CARRYING CONDUCTORS EACH, SHALL APPLY • <br /> T _ I PROPOSED POWER PROTECTIVE CABINET CHARLES NETWORK CABINET THE ADJUSTMENT FACTOR OF 80% PER 2014/17 NEC TABLE 310.15(B)(3)(0) OR <br /> LJ�IMJ EXISTING 120/240V, 1pw, unu7Y UTILITY SERVICE ENTRANCE 1p LUL1 p POWER SERVICE 2020 NEC TABLE 310.15(C)(1) FOR UL1015 WIRE <br /> rY y-1 COMPANY TRANSFORMER 1 120/240 VAC 1PH N3R, 65K/IOK ACd „„,, sh <br /> " /12 FOR 15A-20A/1P BREAKER: 0.8 x 30A = 24.0A <br /> I [ BACKUP MAIN BREAKER WITH #10 FOR 25A-30A/2P BREAKER: 0.8 x 40A = 32.0A <br /> GENERATOR 200A 200A INTERLOCKED GENERATOR (2) PROPOSED #8 FOR 35A-40A/2P BREAKER: 0.8 x 55A - 44.0A <br /> NEW WIRE AND CONDUIT PER UTILITY CAMLOCK FEED, 200A 65K NC #6 FOR 45A-60A/2P BREAKER: 0.8 x 75A - 60.OA <br /> COMPANY REQUIREMENTS GEN PLUG 0.75' EMT CONDUITS whims_ <br /> O N CONDUIT SIZING: AT 40% FILL PER NEC CHAPTER 9, TABLE 4, ARTICLE 358. <br /> SURGE SUPPRESSION 0.5' CONDUIT - 0.122 SQ. IN AREA <br /> DEVICE 100KA SAD4AOV 0.75' CONDUIT - 0.213 SQ. IN AREA 5701 SOUTH SANTA FE DRIVE <br /> 2.0' CONDUIT - 1.316 SQ. IN AREA LITTLETON, CO 80120 <br /> GFCI 15A 01 02 30A PROPOSED 2 #10, 1 #10 CU GND. r FOR RECTIFIER 1 3.0' CONDUIT - 2.907 SQ. IN AREA <br /> NEW 200A, 120/240V, 1+3W, SERVICE RATED, 15A-' �� CABINET CONVENIENCE OUTLET CONDUCTORS (1 CONDUIT): USING THWN-2, CU. <br /> FUSIBLE DISCONNECT(NBA 3R). <br /> (SQUARE D MODEL No. D224NR8/OR EQUIVALENT). 5p ��30A PROPOSED 2 #10 s FOR RECTIFIER 2 #10 - 0.0211 SQ. IN X 2 - 0.0422 SQ. IN <br /> VERIFY COMPA1181LTIY WITH LOCAL UTILITY COMPANY. f�07 08 f� J #10 - 0.0211 SQ. IN X 1 - 0.0211 SQ. IN <GROUND <br /> I LOCATION OF AWN BONDING JUMPER. <br /> SPACE 09 10� PROPOSED 2 #10, 1 #10 CU GND. TOTAL - 0.0633 SO. IN O <br /> 200 SPA-CE 30A _. A s FOR RECTIFIER 3 <br /> _ �11 12� 0.5' EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTA_OF(3) WIRES, <br /> #4 CU (GROUNDING SPACE INCLUDING GROUND WIRE,AS INDICATED ABOVE. O At <br /> ELECTRODE CONDUCTOR) (3) 3/0 WITH#6 GROUND f�13 14f� PROPOSED 2 #10 <br /> IN 3'SOT 40 CONDUIT SPACE5 16�30A J s FOR RECTIFIER 4 RECTIFIER CONDUCTORS (2 CONDUITS): USING UL1015, CU. <br /> SPACE 17 18 f� #10 - 0.0266 SQ. IN X 4 - 0.1064 SQ. IN <br /> SPACE SPACE #10 - 0.0082 SQ. IN X 1 - 0.0082 SQ. IN <BARE GROUND 1000 HOLCOMB WOODS PKWY, <br /> I f-�19 20fm, (1) PROPOSED SUITE 210 <br /> SPACE SPACE 0.5' EMT CONDUIT TOTAL = 0.1146 SO. IN ROSWELL, GA 30076 <br /> GROUNDING ELECTRODE SHALL BE-17 <br /> E f�21 22 f� 678-280-2325 <br /> (2) 5/8'0 X 10' LONG GROUND ROD SPACE 23 24f-SPACE 0.75'EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (5) WIRES, <br /> SPACED MINIMUM 6'APART SPA-CE SPACE INCLUDING GROUND WIRE,AS INDICATED ABOVE. <br /> PROPOSED 2 #10, 1 #10 CU GND. 0 s FOR CONVENIENCE OUTLET PPC FEED CONDUCTORS (1 CONDUIT): USING TWIN, CU. <br /> 3/0 - 0.0507 SQ. IN X 3 - 0.0507 SQ. IN 60 <br /> 9 . <br /> #6 - 0.0507 SQ. IN X 1 = 0.0507 SQ. IN <GROUNDBM <br /> FINAL REFER TO CIRCUIT WIRING SUPPLYING RECTIFIERS ARE TO BE RATED UL1015, 105'C, 600V, AND PVC INSULATED, IN THE SIZES SHOWN TOTAL - 0.8544 SQ. IN ;_ Q�_ <br /> IN THE ONE-UNE DIAGRAM. CONTRACTOR MAY SUBSTITUTE UL1015 WIRE FOR THWN-2 FOR CONVENIENCE OUTLET BRANCH CIRCUIT. <br /> BREAKERS REQUIRED 3.0'SCH 40 PVC CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF(4) WIRES, <br /> INCLUDING GROUND WIRE,AS INDICATED ABOVE. i )' <br /> (4) 30A, 2P BREAKER - SQUARE D P/N:Q0230 a� <br /> (1) 15A, IP BREAKER - SQUARE D P/N:Q0115 N _ <br /> ,,,, 44941.099396, <br /> 470 <br /> 'VIAL° <br /> .3110(2022 <br /> PPC ONE-LINE DIAGRAM No SCALE 1 UBI NUMBER: 604-106-184 <br /> IT IS A VIOLATION OF LAW FOR ANY PERSON, <br /> UNLESS THEY ARE ACTING UNDER THE DIRECTION <br /> OF A LICENSED PROFESSIONAL ENGINEER, <br /> TO ALTER THIS DOCUMENT. <br /> DRAWN BY: CHECKED BY:APPROVED BY: <br /> JDJ/LTH DM MSB <br /> RFDS REV #: --- <br /> CONSTRUCTION <br /> DOCUMENTS <br /> PROPOSED CHARLES PANEL SCHEDULE SUBMITTALS <br /> VOLT AMPS VOLT AMPS REV DATE DESCRIPTION <br /> LOAD SERVED (WATTS) TRIP C# PHASE Co TRIP (WATTS) LOAD SERVED A 06/03/21 ISSLIFD FOR RFVdI <br /> L1 L2 L1 L2 <br /> PPC GFCI OUTLET 180 .. 15A 1 r- A � 2 30A 2880 ABB/GE INFINITY B 10/0S/21 REVISED PER CONENIS <br /> CHARLES GPO OUTLET - 180 15A 3 r- B 4 "' 2880 RECTIFIER 1 <br /> 0 03/10/22 ISSUED FOR COl6TRUCTgN <br /> -SPACE- .. - 5 -/". A -fp- 6 2880 ABB/GE INFINITY <br /> -SPACE- 7 r- B ,,N... 8 - 2880 RECTIFIER 2 - <br /> _ <br /> -SPACE- 9 -EN- A 10 2880 ABB/GE INFINITY <br /> -SPACE- 11 r- B 12 .;_':_. 2880 RECTIFIER 3 <br /> -SPACE- 13 r- A 14 2880 ABB/GE INFINITY <br /> -SPACE- 15 r- 8 16 ....._._. 2880 RECTIFIER 4 <br /> -SPACE- _. 17 r- A r.18 ..:_._. -SPACE- <br /> -SPACE- 19 r- B r-20 -SPACE- A&E PROJECT NUMBER <br /> -SPACE- 21 r- A r-22 -SPACE- <br /> -SPACE- 23 r- 8 ..rti 24 . .. -SPACE- 21 CCD5N-001 7 <br /> VOLTAGE AMPS I 180 1 180 1 11520 1 11520 , <br /> 200A MCB, If,24 SPACE,120 240V L1 L2 <br /> TAB RATING: 65,000 AID 11700 11700 VOLTAGE AMPSDISHWireless L.L.C. <br /> 98 98 AMPS PROJECT INFORMATION <br /> 98 MAX AMPS <br /> 123 MAX 125% SESEA00152A <br /> 2215 MERRILL CREEK PKWY <br /> EVERETT, WA 98203 <br /> SHEET TITLE <br /> ELECTRICAL ONE-LINE, FAULT <br /> CALCS & PANEL SCHEDULE <br /> SHEET NUMBER <br /> E-3 <br /> PANEL SCHEDULE NO SCALE 2 NOT USED NO SCALE 3 <br />