2215 MERRILL CREEK PKY 2022 DISH WIRELESS ANTENNA Plans 2024-05-14
>
Address Records
>
MERRILL CREEK PKY
>
2215
>
DISH WIRELESS ANTENNA
>
Plans
>
2215 MERRILL CREEK PKY 2022 DISH WIRELESS ANTENNA Plans 2024-05-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2024 2:30:05 PM
Creation date
5/14/2024 2:29:27 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2215
Tenant Name
DISH WIRELESS ANTENNA
Permit
B2203-053
Year
2022
Notes
MODIFICATIONS TO EXTG WIRELESS FACILITY - TOWER & GROUND WORK
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GROUNDING NOTES; <br /> ( 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, UGHTNING PROTECTION AND AC POWER GES'S) SHALL • <br /> BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. <br /> 2. THE CONTRACTOR SHALL PERFORM IEEE FALL—OF—POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR <br /> GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO <br /> ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. <br /> 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO wireless- <br /> PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. <br /> 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY 5701 SOUTH SANTA FE DRIVE <br /> BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. UTTLETON, CO 80120 <br /> 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS <br /> WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS <br /> EQUIPMENT. <br /> 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL <br /> EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 0 <br /> 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE O <br /> OF THE GROUND BUS ARE PERMITTED. <br /> 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED 1000 HOLCOMB WOODS PKWY, <br /> COPPER UNLESS OTHERWISE INDICATED. SUITE 210 <br /> 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. ROSWELL, GA 30076 <br /> 678-280-2325 <br /> 10. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY <br /> SUPPORTED. <br /> 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. <br /> 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. OOPO*, <br /> 01 W <br /> 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. Q� <br /> 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND Aaj/( <br /> )BAR. r <br /> 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND <br /> CONNECTIONS. �,SS149� <br /> 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 4kd`�g��g <br /> ALO <br /> 17. MISCELLANEOUS ELECTRICAL AND NON—ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND BIOA' <br /> RING, IN ACCORDANCE WITH THE NEC. .3/10/2D22. <br /> 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOUD TINNED COPPER GROUND UBI NUMBER: 604-106-184 <br /> CONDUCTOR. IT IS A VIOLATION OF LAW FOR ANY PERSON, <br /> UNLESS THEY ARE ACTING UNDER THE DIRECTION <br /> 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND UGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED OF A LICENSED PROFESSIONAL ENGINEER, <br /> THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CUPS OR To ALTER THIS DOCUMENT. <br /> SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL DRAWN BY: CHECKED BY:APPROVED BY: <br /> CONDITIONS, NON—METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., <br /> NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. JDJ/LTH DM MSB <br /> 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" RFDS REV #: --- <br /> NON—METALUC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD—WELD TERMINATION POINT. THE EXPOSED END <br /> OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). CONSTRUCTION <br /> 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE DOCUMENTS <br /> TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING <br /> SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO SUBMITTALS <br /> THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, UGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER UNE REV DATE DESCRIPTION <br /> (FERROUS OR NONFERROUS METAL PIPING ONLY). DO NOT ATTACH GROUNDING TO FIRE SPRINKLER SYSTEM PIPES. A Oe/03/21 ISSUED FOR REVEEN <br /> S 10/00/21 REVISED PER COLIMEIflS <br /> O 03/10/72 ISSUED FOR CONSIROCORN <br /> A&E PROJECT NUMBER <br /> 21CCD5N-0017 <br /> DISH Wireless L.L.C. <br /> PROJECT INFORMATION <br /> SESEA00152A <br /> 2215 MERRILL CREEK PKWY <br /> EVERETT, WA 98203 <br /> SHEET TITLE <br /> GENERAL NOTES <br /> SHEET NUMBER <br /> GN-4 <br />