My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2215 MERRILL CREEK PKY 2022 DISH WIRELESS ANTENNA Plans 2024-05-14
>
Address Records
>
MERRILL CREEK PKY
>
2215
>
DISH WIRELESS ANTENNA
>
Plans
>
2215 MERRILL CREEK PKY 2022 DISH WIRELESS ANTENNA Plans 2024-05-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2024 2:30:05 PM
Creation date
5/14/2024 2:29:27 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2215
Tenant Name
DISH WIRELESS ANTENNA
Permit
B2203-053
Year
2022
Notes
MODIFICATIONS TO EXTG WIRELESS FACILITY - TOWER & GROUND WORK
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES <br /> f 1. CONTRACTOR SHALL FIELD VERIFY ALL PROPOSED UNDERGROUND UTILITY CONDUIT DC POWER WRING SWILL BE COLOR CODED AT EACH END FOR IDENTIFYING +24V AND -48V CONDUCTORS. • <br /> ROUTE RED MARKINGS SHALL IDENTIFY +24V AND BLUE MARKINGS SHALL IDENTIFY -48V. <br /> 2. ANTENNAS AND MOUNTS OMITTED FOR CLARITY. r <br /> sh <br /> 3. THE GROUND LEASE PROVIDES BROAD/BLANKET UTILITY RIGHTS. PWR'AND .FBR. <br /> PATH DEPICTED ON A-1 AND E-1 ARE BASED ON BEST AVAILABLE INFORMATION <br /> INCLUDING BUT NOT UNITED TO FIELD VERIFICATION, PRIOR PROJECT <br /> DOCUMENTATION AND OTHER REAL PROPERTY RIGHTS DOCUMENTS. WHEN 1. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMrrT1NG A BID.ANY QUESTIONS ARISING <br /> INSTAIJJNG THE UTILITIES PLEASE LOCATE AND FOLLOW EXISTING PATH. IF EXISTING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTOR'S FUNCTIONS, THE SCOPE OF WORK, OR ANY <br /> PATH IS NOT AN OPTION, PIFBRF NOTIFY CROWN CASTLE REAL ESTATE AS OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT wireless. <br /> FURTHER COORDINATION MAY BE NEEDED. MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. <br /> 2. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL ELECTRICAL CODES AND ALL 5701 SOUTH SANTA FE DRIVE <br /> STATE AND LOCAL CODES, LAWS, AND ORDINANCES. PROVIDE ALL COMPONENTS AND WIRING SIZES AS LITTLETON, CO 80120 <br /> REQUIRED TO MEET NEC STANDARDS. <br /> 3. LOCATION OF EQUIPMENT. CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE <br /> COORDINATED WITH FIELD CONDITIONS PRIOR TO CONSTRUCTION. <br /> 4. CONDUIT ROUGH-IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS. <br /> VERIFY WITH THE MECHANICAL EQUIPMENT CONTRACTOR AND COMPLY AS REQUIRED. <br /> 5. CONTRACTOR SHALL PROVIDE ALL BREAKERS, CONDUITS AND CIRCUITS AS REQUIRED FOR A COMPLETE SYSTEM. O. , <br /> 6. CONTRACTOR SHALL PROVIDE PULL BOXES AND JUNCTION BOXES AS REQUIRED BY THE NEC ARTICLE 314. O <br /> 7. CONTRACTOR SHALL PROVIDE ALL STRAIN RELIEF AND CABLE SUPPORTS FOR ALL CABLE ASSEMBUES. 1000 HOLCOMB WOODS PKWY, <br /> INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. SUITE 210 <br /> ROSWELL, GA 30076 <br /> 8. ALL DISCONNECTS AND CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED PHENOIJC NAMEPLATES 678-280-2325 <br /> INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM. <br /> 9. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC 250. <br /> THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES. PULL BOXES, AND ALL <br /> DISCONNECT SWITCHES, AND EQUIPMENT CABINETS. <br /> 10.ALL NEW MATERIAL SHALL HAVE A U.L LABEL /�p� <br /> 11.PANEL SCHEDULE LOADING AND CIRCUIT ARRANGEMENTS REFLECT POST-CONSTRUCTION EQUIPMENT. <br /> % <br /> EXISTING ICE �.1 y r� <br /> EXISTING 3'-5" BRIDGE (TYP.) 12.CONTRACTOR SHALL BE RESPONSIBLE FOR AS-BUILT PANEL SCHEDULE AND SITE DRAWINGS. CJi[ <br /> MONOPOLE I (AO�- <br /> 5'_9 I - - I 13.ALL TRENCHES IN COMPOUND TO BE HAND DUG <br /> m 11 .per 9..9 <br /> 4 I - - -- 5�1818�" <br /> -�. — EXISTING FORM EQUIPMENT O-8Z . <br /> Clii) <br /> � tI1== -- - 16'-9�, x 23'-6" - S�+�� <br /> r== EXISTING = �-��EXISTING EQUIPMENT 6'-2" ( ) <br /> �� PLATFORM _ —t PLATFORM ELECTRICAL NOTES NO SCALE +3ho/w22 <br /> (14'-3" x 20'-3") 2 UBI NUMBER: 604-106-184 <br /> EXISTING TREES `��' (9'-3" x - pi i f ___ __(TYP.) � _''--12'-9") _ I1-1 /I - ---r- R IS A VIOLATION OF LAW FOR ANY PERSON. <br /> ���V". 1I o UNLESSOF AT LICENSED <br /> ACTING UNDER <br /> THE <br /> DIRECTION <br /> EXISTING _‘-.. <br /> NOTE: TO ALTER THIS DOCUMENT. <br /> TRANSFORMER ' f ;,PROPOSED 3" UNDERGROUND POWER r �' LEGAL DESCRIPTION OF EASEMENTS NOT PROVIDED. CONTRACTOR TO <br /> CONDUIT ROUTED TO DISTING PAD MOUNTED _ M COORDINATE AND ROUTE UTILSES WITHIN EXISTING UTILITY EASEMENT. DISH DRAWN BY: CHECKED BY:APPROVED BY: <br /> TRANSFORMER LENGTH: i5'-0"t "� " WIRFI FQq LLC. SHALL BE RESPONSIBLE FOR OBTAINING EASEMENT RIGHTS <br /> ( ) I EXISTING EQUIPMENT . L , AS REQUIRED FOR INSTALLATION OF ALL UTILITIES. JDJ/LTH DM MSB <br /> PLATFORM <br /> A _ (11't-6" x 23.-6") . . , , RFDS REV #: <br /> - FBR FBR—FBR— FBR <br /> J ) J CONSTRUCTION <br /> PROPOSED 2"SCH 40 PVC UNDERGROUND DOCUMENTS <br /> PROPOSED DISH WIRELESS LLC. FIBER CONDUIT(LENGTH: 35'-0"t) <br /> HANDHOLE(CONTRACTOR TO <br /> SUBMITTALS <br /> FIELD DETERMINE LOCATION) <br /> I Proposed UC Power Rohe from 2w"'. '�• <br /> ®: a ,r: Basting Pad mountTransfomrer a.. REV DATE DESCRIPTION <br /> PROPOSED 2"SCH 40 PVC UNDERGROUND -- © C y. m .Rua n (k 8T)to tOtlaw Etosurlg route to Site A 06/05/21 ___ <br /> FIBER CONDUIT ROUTED TO MEET ME DISH Wireless LLC. IS RESPONSIBLE FOR 4 4 _`` T . - e 0/06/21 RENEW PER COMMENTS <br /> pow AT SEE NOTE R.O.W. (LENGTH: 445'-0"t). OBTAINING ALL EASEMENT RIGHTS REQUIRED FOR r ,�" II 0 OJ 10 <br /> /22 INSTALLATION OF UTILITIES TO RIGHT-OF-WAY. t---. __ .._- N ; A:' - / ��FOR <br /> .•, ` i •. <br /> CONTRACTOR TO SAWCUT AND REMOVE EXISTING CONCRETE AS <br /> REQUIRED FOR INSTALLATION OF UTILITIES. CONTRACTOR SHALL ~ /,�."' c I t , PROPOSED UNDERGROUND 4- t !i <br /> REPAIR ALL CONCRETE TO BETTER OR ORIGINAL CONDITION POST ,.`' FIBER CONDUIT(LENGTH: r, <br /> CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR PROPER 1 _ _ 445'-0"t) SEE NOTE 3 '1 `+ {'�: ` <br /> REMOVAL AND DISPOSAL OF ALL REFUSE 1 t• �• A&E PROJECT NUMBER <br /> i5iTousesi si;- - L , , L. <br /> UFUer Rol 11 <br /> • __ Ar • -rvtrviPHitoHIf . . 21CCD5N-0017 <br /> S T .x ...OW MI.tP HH ' - '�°� <br /> rnp�' coMpound J n. _xistmg Pf)P'�`s'r7 F:t>z'Hsi C`A S..( - - H-FW1Me <br /> be;! f zf DM RON/ remaour4 <br /> 4 t �r J ,} ,L.; DISH Wireless L.L.C. <br /> PROJECT INFORMATION <br /> SESEA00152A <br /> 2215 MERRILL CREEK PKWY <br /> EVERETT, WA 98203 <br /> SHEET TITLE <br /> ELECTRICAL/FIBER ROUTE_ <br /> PLAN AND NOTES <br /> IlliVi SHEET NUMBER <br /> 8' 4' 0 8' 16' E-1 <br /> UTILITY ROUTE PLAN , - - - - 1 OVERALL UTILITY PLAN NO SCALE 3 <br /> 1/8"=1'-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.