Laserfiche WebLink
• <br /> RR DESIGfl <br /> C <br /> September 29,.2023 <br /> Yin Lu, Residential Building Reviewer <br /> City of Everett <br /> RE: Garcia residence <br /> Consistency Review of <br /> PERMIT APPLICATION#B2306-058 <br /> Dear Garcia, <br /> The plan review comments from the "City of Everett" dated 9/7/23 have been reviewed. <br /> Revisions have been made to the plan as required and are noted as follows- <br /> ARCHITECTURAL /AV <br /> ". <br /> Note has been added to the floor plan, sheed section A, sheet2. The information has been provided. Pleaseo the note "PROVIDE (3) #4 X18" <br /> long rebar dowels. EMBED DOWELS 5 1/2" IN SIMPSON SET3G EPDXY"Per <br /> structural <br /> 3. 1/S3.1 has been revised to include the existing wall. Provide section B for north roof <br /> connection on Sheet A6. <br /> 4. NOTE: EXISTING WALLS ARE ASSUMED TO MEET THE NAILING AND SHEATHING <br /> REQUIREMENTS OF "SW1" IN THE SHEARWALL SCHEDULE. GC SHALL <br /> VERIFY". New shear walls have been tagged on A5. <br /> @L Provide section B for north roof connection on Shee@ <br /> 6. We will keep the existing stair. On the existing and proposed I have labeled it <br /> existing. <br /> 7 Roof plan shows trusses and gable end truss per detail 2/S3.1 on Sheet A5 <br /> Existing fireplace is labeled as Free standing electrical. <br /> Thank you, <br /> Paul CRector <br /> RR DESIGN LLC <br /> paul@rectordesigns.com <br /> 253.332.6244 <br />