Laserfiche WebLink
# DATE/DESCRIPTION <br /> WIRE RUN DETAIILS & OUTSIDE MOUNTED ELECTRONICS/CONTROLLER WITH STEEL POLE DETAIL <br /> 2'-10 7/16" <br /> / / <br /> 79"ABS INSULATOR-DOES NOT ) )f <br /> CONDUCT ELECTRICITY <br /> __37 <br /> 30'-0"SPACING BETWEEN <br /> FIBERGLASS POLES ,mod, / � <br /> - <br /> -stil �39f — �a <br /> ,_—____,\ ( esseneen <br /> Z 2 <br /> n ! <br /> I aF ( I —dd I I I = ' 60. / <br /> o.T, <br /> It <br /> il <br /> 2'-113/4" / 'o <br /> �— l Et E L. <br /> N x <br /> O- J I I a` a r W <br /> �, * t -� SEE CONNECTION - Q <br /> N , <br /> • ALARM PANEL FENCE CONTR NOTES 67 i <br /> ENCLOSURE ENCLOSURE <br /> SILVER BOX 24-5/16"W X�� W <br /> ( r 4 22-1/8"T X 8-7/16"D 0 A u0i B B C W <br /> 1 da 41 IL/ <br /> Q w <br /> I � ` I ` I * � A Z F <br /> x > _�_...................". ,.,._,.�'* II a z 1- o <br /> * �, a E - <br /> ) > w <br /> f49 i FINISH GRADE U D <br /> v *'--- ( C l49 <br /> w <br /> • - - I \ • <br /> \ \ <br /> r <br /> FENCE GROUND <br /> E <br /> ( < FENCE FEED- <br /> > FENCE RETURN -------....\ I I 2,500 PSI CONCRETE I z �? 4 N <br /> (MIN.) �� m <br /> 0 <br /> ' \6 AWG BARE COPPER WIRE <br /> 3'-0" <br /> / = ir 18"DIA.(MIN.) <br /> O 0 0 <br /> O D0 0 <br /> re Z Q co <br /> CONNECTION NOTES: z 0 z }"DIA.X 8'LG.GROUND ROD — N <br /> (TNT.) (/) Z CO <br /> O C O J W CD <br /> A:ALARM PANEL ENCLOSURE-HOUSES THE ALARM CONTROL <br /> PANEL.THIS BOX INTERCONNECTS TO'B"/FENCE CONTROLLER a a aO __Io Q <br /> ENCLOSURE USING THE APS WHIP/10 CONDUCTOR CABLE AND <br /> "C"/SOLAR CHARGE CONTROLLER USING TWO CONDUCTOR O O O U I- <br /> CABLE.ENCLOSURE WEIGHT 21 LBS.(MAX.). ; ; FRONT ELEVATION RIGHT SIDE ELEVATION r LL H <br /> B:FENCE CONTROLLER ENCLOSURE-HOUSES THE FENCE 49"(NP.) m 1.11 W <br /> ENERGIZER OR EQUIVALENT.THIS BOX CONNECTS TO"A"/ w W 0 <br /> ALARM PANEL ENCLOSURE USING THE APS WHIP/10 CONDUCTOR IJ <br /> 11.1 <br /> CABLE.ENCLOSURE WEIGHT 22 LBS.(MAX.). �- �^ Q O w _I <br /> C:SOLAR CHARGE CONTROLLER ENCLOSURE-HOUSES POWER 0 LO U <br /> ELEMENTS FOR SOLAR CHARGE CONTROLLER AND DISCONNECTS a <br /> FOR SOLAR,BATTERY,AND LOAD CONNECTIONS.POWER UP BATTERY 12 VDC d <br /> SOLAR CHARGE BATTERY <br /> PROCEDURE:TURN ON BATTERY BREAKER FIRST,THEN TURN ON '�(MAX.) � <br /> SOLAR BREAKER. THE ELECTRONICS POWER IS CONTROLLED BY CONT ENCL ENCLOSURE I- <br /> BY THE LOAD BREAKER. ENCLOSURE WEIGHT 25 LBS.(MAX.). 0 C Q D J <br /> D:BATTERY ENCLOSURE-HOUSES THE BATTERIES AND INTER- .a. .-- <br /> CONNECTS TO"C"/SOLAR CHARGE CONTROLLER ENCLOSURE <br /> USING TWO CONDUCTOR 14G AND 10G THWN WIRES.ENCLOSURE NOTES: w w <br /> aw <br /> WEIGHT 145 LBS.(MAX.)-BATTERY WILL NOT EXCEED 70KWH. -4- -'V- n = <br /> MOUNT SILVER BOXES TO A PAIR OF 4"X4"X180"LG.GALVANIZED ASTM In <br /> E:KEYPAD ENCLOSURE-HOUSES THE KEYPAD.THIS BOX A500 STEEL POLES.BOTTOM OF THE LOWEST BOX MUST BE A MINIMUM <br /> INTERCONNECTS TO"B"USING 10 CONDUCTOR/18 AWG WIRE. OF 2 FEET ABOVE GROUND LEVEL.THE SUPPORT POLES MUST BE VIEW A-A DATE: 2/17/2022 <br /> ENCLOSURE WEIGHT 12 LBS.(MAX.). EMBEDDED AT A MINIMUM OF 4'-0"BELOW GROUND LEVEL. (KEYPAD ENCLOSURES REMOVED <br /> FOR CLARITY) <br /> SCALE: SEE PLAN <br /> SHEET <br /> r C-3 <br /> of 3 <br />