3710 TULALIP AVE 2021 Plans 2024-05-15
>
Address Records
>
TULALIP AVE
>
3710
>
Plans
>
3710 TULALIP AVE 2021 Plans 2024-05-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/15/2024 8:05:02 AM
Creation date
5/15/2024 8:04:43 AM
Metadata
Fields
Template:
Address Document
Street Name
TULALIP AVE
Street Number
3710
Permit
B2106-045
Year
2021
Notes
REMOVE (1) DIPOLE ANTENNA / (3) OMNI ANTENNAS AND RELOCATE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> 24'WIDE <br /> 14'SEISMIC EQUIPMENT RACK(CHATSWORTH PRODVCTSI _ CAUTION SNO 911 <br /> 24'WIDE 1AN 15-DEEP <br /> STANDARD 7'-D"HEIGHT. SNOHOMISH COUNTY <br /> NEIGHT WITH T PICAL COMMUNICATIONS EQUIPMENT-3500 LBS I 911 <br /> I <br /> NOTE <br /> 1121 SE EVERETT MALL WAY <br /> SUITE 200 <br /> 18ee EVERETT,425.407 3911 <br /> . Beyond this point: <br /> Radio frequency fields at this site <br /> may exceed FCC rules for human <br /> • <br /> exposure. <br /> For your safety, obey all posted signs <br /> STANDARD 19'SEISMIC RACK and site guidelines for working in <br /> '=EMI J IA radio frequency environments. <br /> INTERIOR EQUIPMENT RACKS TO BE E radio <br /> i"x"""Commodalls•Om..No 0 <br /> .17 m 11.44 <br /> ATTACHED TO FLOOR CF SHELTER PER <br /> SPECIFICATIONS BELOW <br /> RADIO FREQUENCY SIGN SCALE NTS 17 <br /> EX.CHU WALL.CONTRACTOR TO CUT OUT AN �yY~uC;4+ <br /> 18'%18'SQUARE HOLE IN THE EX � � y''yc a '4;`t <br /> EQUIPMENT,TOP .�E� '+ I., � CMU WALL FORA NEW B I I A L .1 Yp <br /> I PORT"PEEP'UNIT t� <br /> _� MN <br /> 4x4e6,GALVANIZED STEEL ANGLE ACROSS 2'-0'WOE CABLE BRIDGE SECTION TO BE INSTALLED TO MATCH ✓ '4h Mb <br /> 1 THE TOP OF THE CUT IN THE CMU WALL _I 1 ' <br /> I I 1 ANGLE MUST BEAR ONTO EXISTING WALL '111 HEIGHT OF EXISTING CABLE BRIDGE ACROSS THE FACADE OF THE �nLe 'r <br /> I <br /> EQUIPMENT BUILDING.SECURE THE PROPOSED CABLE BRIDGE M� <br /> EACH SIDE �v SECTION TO THE GALVANIZED ANGLE AT THE BRIDGE FLANGE USING 7; <br /> �,�..9�li1I',� <br /> !! / Yi O STAINLESS STEEL THROUGH BOLTS.ATTACH THE OPPOSITE END <br /> {-� GROUNDING KIT,lYP COAX OF THE PROPOSED SECTION TO THE EXISTING CABLE BRIDGE USING <br /> I I —�..�N q—IU�I'�lIIINIIIIIIII: Y.'O THROUGH BOLTS AT 6"DC.ACROSS THE FACE OF THE THIS DRAWING IS COPYRIGHTED AND IS THE <br /> FINISHED SHELTER BUILDING IIMMI1011111 FINISHED SH TER •UILDIN SECTION. SOLE PROPERTY OF THE OWNER. IT IS <br /> �I LFM• Lr7. --am,l ',111111111111111111E PRODUCED SOLELY FOR USE BY THE OWNER <br /> POLYPHASER,TYP ATTACH Z15'X 2YN'X Y.'GALVANIZED STEEL AND ITS AFFIUATES. REPRODUCTION OR USE <br /> / I—.1OAOAX ANGLE TO CMU WALL W/!6'P MASO7RY OF THIS DRAWING AND/OR THE INFORMATION <br /> BASE ANCHOR VOA SY' COPPER FRAME) '■ EXPANSION BOLTS 0 12"OC(EMBED 3'). CONTAINED IN IT IS FORBIDDEN WITHOUT THE <br /> WTI N 4 T HUT KM BOLT-TZ2 VERIFY PER MEWS.SPECIFICATIONS WRITTEN PERMISSION OF THE OWNER. <br /> ANCHOR HOLES EXPANSION ANCHOR, <br /> (PEEP UNIT) <br /> PER EQUIPMENT TOP OF 4 PEEP UNIT,TYP 1 9(II <br /> RACK EXTER <br /> COPPER PLATE I/I <br /> PLATENAL COPPER 1 <br /> i_1,,\ <br /> INTERIOR MASTER GROUND BAR,CONTRACTOR t <br /> SUPPUED AND INSTALLED.SEE DETAIL 17 SHEET G-2. CONTINUOUS BEAD OF SEALANT AT <br /> IICIPKIII PERIMETER EDGE OF COAX PORT AND <br /> GALVANIZED STEEL ANGLE //��G <br /> SEISMIC EQUIPMENT RACK SCALE:1)'-r ��, <br /> -o' 6 CABLE PORT DETAIL SCALE: 1'-1'-0' 14 NorthWest <br /> RATTTRY MFG.FNFRSYS PI WERSAFF Tower Engineering <br /> BATTERY TYPE• VIOLA. , <br /> NO OF BATTLIALS 24 BATTERY CELLS IN 3X8 CONFIGURATON <br /> MOM, OO'Pt00-21 IN UBC RACK: <br /> 'NOMNAL AA CAPICITY'1000 7 <br /> ELECTROLYTE VOTIVE PM BATTERY CELL 3.20 GALLONS <br /> FI ECTPGLYTE VIA I IMF TOTAL• 76 80 CAI I ONS, <br /> DIMENSIONSJCELLS AND 118C RA .): 2582,W x_25,25"D x 7811'H RELEASE <br /> TOTAL WIGHT(BATTERY CFAS AND INC1 RACK): 4.440 IRS, TABLE 608.1 DATE <br /> NON-SPILLARLE CLASSIFICATION:UN2800 I NATIONAL FIRE CODE <br /> APPROVED/CERTIFIED• 150 9001: 2008 AND ISO 14001• 7004 BATTERY REQUIREMENTS 16FEB21 PERMIT REVIEW SET <br /> BATTERY SYSTEM DATA OTHER 02APR21 BUILDING PERMIT SET <br /> NONRECOMBINANT BATTERIES RECOMBINANT BATTERIES BATTERIES <br /> REQUIREMENT VALVE REGULATED <br /> VENTED(FLOODED) VENTED(FLOODED) LEAD ACID LITHIUM-ION UTHIUM METAL <br /> LEAD ACID NICKEL-CADMIUM BATTERIES(VIOLA) CELLS CELLS <br /> BATTERIES (NI-Cd)BATTERIES BATTERIES <br /> SELF-RESEALING <br /> SAFETY CAPS VENTING CAPS VENTING CAPS FLAME ARRESTING NO CAPS NO CAPS <br /> 608.2.1 608.2.1 CAPS <br /> 608.2.2 STE NAME <br /> THERMAL <br /> RUNAWAY NOT REWIRED NOT REWIRED REQUIRED NOT REQUIRED REQUIRED RUCKER ANTENNA ADDITION PROJECT <br /> MANAGEMENT 608.3 608.3 RUCKER COMMUNICATION FACILITY <br /> ENERYSYS DDmP100-21 <br /> BATTERY RACK SPILL CONTROL REWIRED REWIRED REWIRED NOT REWIRED NOT REQUIRED y� <br /> 608.5 608.5 608.5 <br /> ADDRESS <br /> OM— MI <br /> UBC BATTERY RACKS TO BE ATTACHED � . 700 EDWARDS AVENUE <br /> TO FLOOR OF SHELTER/BUILDING PER I . I !I NEUTRALIZATION REQUIRED REQUIRED REQUIRED NOT REQUIRED NOT REQUIRED EVERETT, WA 98201 <br /> SPECIFICATIONS BELOW 608.5.1 608.5.1 608.5.1 <br /> ii: <br /> mil iii VENTILATION REQUIRED REWIRED REWIRED NOT REQUIRED NOT REQUIRED <br /> Im i I 608.6.6&608.6.2 608.6.6&608.6.2 608.6.6&608.6.2 <br /> _ <br /> BATTERY CELL TYPICAL OF 24 Imam' _ REWIRED REWIRED REQUIRED REWIRED REWIRED CITY OF EVERETT <br /> SIGNAGE 608.7 BOB.? 608.7 608.7 608.7 <br /> Immo SEISMIC REWIRED REWIRED REWIRED REQUIRED REQUIRED REVIEWED FOR PERMIT <br /> IpwEsI xl PROTECTION 608.8 608.8 608.8 608.8 608 8 <br /> �z I �� <br /> IFESEll G _ SMOKE DETECTION REWIRED REQUIRED REQUIRED REWIRED REQUIRED SHEET TLTLE <br /> W 608.9 608.9 608.9 608.9 608.9 <br /> ICI :I CONSTRUCTION DETAILS <br /> NI• A. HA R l I TIN Y., ...T FINISH I SR R :1I I <br /> FL.'' I FLOOR <br /> UBC ANCHOR RACK,WITH 8 VOA Sr HILT KIRK BOLT-TZ2 EXPANSION I SHEET NUMBER <br /> ANCHOR HOLES PER BATTERY RACK FRCNT ANCHOR,TYP OF 4 PER CHANNEL 5-12E. <br /> S-4 <br /> DDmP100-21 BATTERY RACK SCALE:K'-I'-o' 16 PLOT SCALE 1:1 0 24'x36': 1:2 011'x17' <br />