Laserfiche WebLink
• • <br /> depth after notching for stairs.Sistered framing is recommended to control deflections for long spans; <br /> fasteners should be specified. See Sections R106.1.1 and R301.1. <br /> Stair construction details and joist spacing/span details added to A-1. <br /> 3. See Sheet S2. Detail B/S2 is specified on the plans at locations where it appears to not apply <br /> including but not limited to the front wall where sections show a retaining wall. <br /> S2 updated to show daylight basement wall details, note that it's restrained at the top with the floor <br /> diaphragm, so it's not a retaining wall. <br /> 4. See retaining wall calculations. Address the following: <br /> a. Retaining walls should be designed to resist sliding and overturning with a minimum safety <br /> factor of 1.5 in each case. See IBC Section 1807.2.3 for more information. <br /> b. Concrete strength (f c=4,000 psi) should be specified on the plans. It appears that Special <br /> Inspection is required per IBC Section 1705.3. A statement on special inspections has not been <br /> provided and should be provided on the plans. The statement should include a table listing each <br /> type of special inspection and should specify the extent of each inspection (e.g., continuous, <br /> periodic) per IBC Section 1704.3.1. <br /> Min 4000 psi concrete added to notes. Please note that Basement Foundation designed with 2500 psi so <br /> special inspection not required.4000 psi requirement is standard for durability, not code strength <br /> requirement. Code has not caught up to concrete production requirements, concrete suppliers don't <br /> even deliver concrete that weak anymore. Its standard to specify and use 4-5K psi mix which is above <br /> code requirements. <br /> 5. See Foundation Reinforcing Table and Detail on Sheet S2. Address the following: a. Detail <br /> should be updated to include distances for minimum concrete cover. <br /> b. The foundations should be founded a minimum of 18"below grade for frost protection per <br /> EMC Section 16.01.010(J). <br /> See updated drawing as described in #3 response. <br /> c. The depth of soil being retained by below-grade walls should be specified. <br /> See updated drawing as described in #3 response. <br /> d. Footing drains should be provided per Section R405. <br /> See updated drawing as described in #3 response. <br /> 6. See seismic calculations in the provided structural calculations. Provide code section <br /> references for the exceptions stated in the structural calculations (Seismic analysis not required <br /> if conventional framed wood walls and roof, aspect ratio is less than 2.5, and ground snow is <br /> less than 30 psf) or provide seismic analysis. See Section 1613.1 for exceptions. <br /> 23 <br />