My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2404 74TH ST SE 2022 Plans 2024-05-16
>
Address Records
>
74TH ST SE
>
2404
>
Plans
>
2404 74TH ST SE 2022 Plans 2024-05-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2024 2:13:51 PM
Creation date
5/16/2024 11:58:45 AM
Metadata
Fields
Template:
Address Document
Street Name
74TH ST SE
Street Number
2404
Permit
B2202-028
Year
2022
Notes
REPAIR & REMODEL TO AN EXTG RESIDENTIAL STRUCTURE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 406.3 • <br /> ENERGY CREDITS • <br /> CREDIT(S) <br /> OPTION DESCRIPTION ------- I <br /> All Other Group R-2 <br /> 1.EFFICIENT BUILDING ENVELOPE OPTIONS —� <br /> Only one option from Items 1.1 through 1.7 may be selected in this category. <br /> Compliance with the conductive UA targets is demonstrated using Section R402.1.4,Total UA alternative,where <br /> [1-(Proposed UA/Target UA)]>the required%UA reduction <br /> —— —�-- —1.1 Prescriptive compliance is based on Table R402.1.1 with the following 0.5 0.5 ----y <br /> modifications: <br /> Vertical fenestration U=0.24. <br /> 1.2 Prescriptive compliance is based on Table R402.1.1 with the following 1.0 1.0 <br /> modifications: <br /> Vertical fenestration U=0.20. <br /> 1.3 . Prescriptive compliance is based on Table R402.1.1 with the following tk 3 N/A <br /> modifications: <br /> Vertical fenestration U=0.28 <br /> Floor R-38 <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total conductive UA <br /> by 5%. <br /> 1.4 Prescriptive compliance is based on Table R402.1.1 with the following 1.0 1.0 <br /> modifications: <br /> Vertical fenestration U=0.25 <br /> Wall R-21 plus R-4 ci <br /> Floor R-38 <br /> Basement wall R-21 int plus R-5 ci <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total conductive UA <br /> by 15%. <br /> 1.5 Prescriptive compliance is based on Table R402.1.1 with the following 2.0 1.5 -1 <br /> modifications: <br /> Vertical fenestration U=0.22 <br /> Ceiling and single-rafter or joist-vaulted R-49 advanced <br /> Wood frame wall R-21 int plus R-12 ci <br /> Floor R-38 <br /> Basement wall R-21 int plus R-12 ci <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total conductive UA <br /> by 30%. <br /> RE-42 2018 Washington State Energy Code <br />
The URL can be used to link to this page
Your browser does not support the video tag.