2404 74TH ST SE 2022 Plans 2024-05-16
>
Address Records
>
74TH ST SE
>
2404
>
Plans
>
2404 74TH ST SE 2022 Plans 2024-05-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2024 2:13:51 PM
Creation date
5/16/2024 11:58:45 AM
Metadata
Fields
Template:
Address Document
Street Name
74TH ST SE
Street Number
2404
Permit
B2202-028
Year
2022
Notes
REPAIR & REMODEL TO AN EXTG RESIDENTIAL STRUCTURE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 406.3(continued) <br /> ENERGY CREDITS <br /> a --- CREDIT(S) <br /> OPTION DESCRIPTION <br /> All Other Group R-2 <br /> 2.2 F Compliance based on Section R402.4.1.2: 1.0 1.5 <br /> Reduce the tested air leakage to 2.0 air changes per hour maximum at 50 <br /> Pascals <br /> or <br /> For R-2 Occupancies,optional compliance based on Section R402.4.1.2: <br /> Reduce the tested air leakage to 0.25 cfm/ft2 maximum at 50 Pascals <br /> and <br /> All whole house ventilation requirements as determined by Section <br /> M1507.3 of the International Residential Code or Section 403.8 of the <br /> International Mechanical Code shall be met with a heat recovery ventilation <br /> system with minimum sensible heat recovery efficiency of 0.65. <br /> To qualify to claim this credit,the building permit drawings shall specify the <br /> option being selected and shall specify the maximum tested building air <br /> leakage and shall show the heat recovery ventilation system. <br /> 2.3 Compliance based on Section R402.4.1.2: 1.5 2.0 <br /> Reduce the tested air leakage to 1.5 air changes per hour maximum at 50 <br /> Pascals <br /> or <br /> For R-2 Occupancies,optional compliance based on Section R402.4.1.2: <br /> Reduce the tested air leakage to 0.25 cfm/ft2 maximum at 50 Pascals <br /> and <br /> All whole house ventilation requirements as determined by Section <br /> M1507.3 of the International Residential Code or Section 403.8 of the <br /> International Mechanical Code shall be met with a heat recovery ventilation <br /> system with minimum sensible heat recovery efficiency of 0.75. <br /> To qualify to claim this credit,the building permit drawings shall specify the <br /> option being selected and shall specify the maximum tested building air <br /> leakage and shall show the heat recovery ventilation system. <br /> F <br /> 2.4 rCompliance based on Section R402.4.1.2: 2.0 2.5 —' <br /> Reduce the tested air leakage to 0.6 air changes per hour maximum at 50 <br /> Pascals <br /> or <br /> For R-2 Occupancies,optional compliance based on Section R402.4.1.2: <br /> Reduce the tested air leakage to 0.15 cfm/ft2 maximum at 50 Pascals <br /> and <br /> All whole house ventilation requirements as determined by Section <br /> M1507.3 of the International Residential Code or Section 403.8 of the <br /> International Mechanical Code shall be met with a heat recovery ventilation <br /> system with minimum sensible heat recovery efficiency of 0.80. Duct <br /> installation shall comply with Section R403.3.7. <br /> To qualify to claim this credit,the building permit drawings shall specify the <br /> option being selected and shall specify the maximum tested building air <br /> leakage and shall show the heat recovery ventilation system. <br /> RE-44 2018 Washington State Energy Code <br />