My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2111 63RD ST SE 2024-06-06
>
Address Records
>
63RD ST SE
>
2111
>
2111 63RD ST SE 2024-06-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2024 7:32:24 AM
Creation date
5/28/2024 10:11:45 AM
Metadata
Fields
Template:
Address Document
Street Name
63RD ST SE
Street Number
2111
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INVERTER SPECIFICATIONS RAPID SHUT DOWN DEVICE SPECIFICATIONS AMBIENT TEMPERATURE SPECIFICATIONS CONTRACTOR <br /> MANUFACTURER/ MODEL# SOL-ARK 15K-2P (240V) TIGO TS4-A-O RAPID SHUT DOWN RECORD LOW TEMP -5°C <br /> MANUFACTURER/ MODEL # DEVICE AMBIENT TEMP(HIGH TEMP 2%AVG.) 26°C <br /> MPPT VOLTAGE RANGE 150-425V <br /> POWER RATING 15,000W INPUT VOLTAGE RANGE 16 - 80V MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE 7/8" <br /> CONT. OUPUT CURRENT 62.5A MAX CONT. CURRENT 15A <br /> CEC EFFICIENCY 96.50,/Io MAX SHORT CIRCUIT CURRENT 120A <br /> MAX INPUT CURRENT 26A SOLAR MODULE SPECIFICATIONS UNIVERSAL ELECTRIC PNW <br /> MANUFACTURER/MODEL# SILFAB SOLAR SIL-410 BG <br /> MAX DC VOLTAGE 500V VMP 38.07v 1010 SE EVERETT MALL WAY, <br /> IMP 10.77A EVERETT, WASHINGTON <br /> METAL CONDUIT REQUIRED FOR DC CONDUCTORS VOC 45.92V 98208 <br /> VMAX=VOC+((TLOW-TSTC)X(VOCCOEFXVOC/100)) THAT ARE RAN INTERIOR OF BUILDING <br /> VMAX=45.92+(-5-25)x(-0.279 x 45.92/100) ISC 11.30A <br /> PHONE-(425)610-9634 <br /> VMAX=45.92+(- x(-0.279 x 0.4592) TEMP.COEFF.VOC -0.279%/°C <br /> VMAX=45.92+(-30)30)x x(-0.12811) LIC. NO. -604939882 <br /> VMAX=45.92+3.843 <br /> VMAX-49.763V (N)SOL-ARK 15K-2P(240V)INVERTER <br /> VMAX FOR 10 MODULES=497.63 OUTPUT:240VAC,62.5A <br /> DC SYSTEM VOLTAGE OF INVERTER=500V <br /> 500/49.763=10.047 NEMA 3R,UL LISTED, INTERNAL GFDI <br /> (ON GARAGE) METER#: 1000650963 <br /> SOL-ARK TO UTILITY GRID <br /> L 1 L2 N <br /> (E) 100A SUB PANEL, (E)BI-DIRECTIONAL <br /> (N)AC DISCONNECT: 240V LINE UTILITY METER <br /> aAT P,P z P 3 VISIBLE, LOCKABLE, LABELED (INSIDE GARAGE) 1-PHASE,LOAD SIDE <br /> 100A FUSED, (2)80A FUSES, CONNECTION M > 120V/240V W <br /> _ 240V, NEMA 3R, UL LISTED TRENCHED <br /> METAL CONDUIT REQUIRED FOR DC CONDUCTORS (ON GARAGE) CONDUIT (OVERHEAD SERVICE) <br /> LOAD <br /> THAT ARE RUN INTERIOR OF BUILDING L1 L1 L1 <br /> L2 L2 L2 PROJECT NAME &ADDRESS <br /> (N)TIGO RSS N N N <br /> SILFAB SOLAR SIL-410 BG TRANSMITTER G G G JOSEPH SEVERANCE <br /> 2 r ( (N)200A/2P MAIN 2111 63RD ST SE, <br /> ___ ____ ___ _ 3 _ 3 l \ BREAKER, 240V <br /> r— E .1. EVERETT, WA 98203 <br /> I I � (TOP FED) <br /> 1 2 0 0 0 9 10 o'j` (E) 100A/2P MAIN o APN#: 00544900301100 <br /> I ^� <br /> L= + __ + ______ + __ + <br /> (N)JUNCTION BOX o BREAKER,240V <br /> 600V,NEMA 3R UL AHJ: CITY OF EVERETT <br /> = LISTED O O <br /> (ON GARAGE) o (N) 100A/2P (N)200A MAIN UTILITY: SNOHOMISH PUD <br /> + + 0-- <br /> 000 + + N SERVICE PANEL, <br /> u000_u <br /> 240V SYSTEM DETAILS <br /> DC SIZE:11.480 KW DC-(STC) <br /> 000 N A(28)SILFAB SOLAR SIL-410 BG <br /> LOAD SIDE G (01)SOL-ARK 15K-2P(240V) <br /> INTERCONNECTION (28)TIGO TS4-A-O RAPID SHUT DOWN DEVICE <br /> u AT SUB PANEL GEC <br /> EXISTING GROUNDING <br /> 1 ELECTRODE SYSTEM REVISIONS <br /> 000 9 <br /> REV DESCRIPTION DATE <br /> V I n TT <br /> + + INSTALL NEW MAIN SERVICE <br /> °°° PANEL 200A/200A RATED <br /> TIGO TS4-A-O RAPID <br /> SHUT DOWN DEVICE <br /> DESCRIPTION FORMULA RESULT SHEET TITLE <br /> PV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25=(01 x 62.5)A x 1.25 78.13A (SELECTED OCPD =80A) ELECTRICAL <br /> DC WIRE CACLULATION DIAGRAM <br /> EXPECTED TEMP QTY OF CURRENT CONDUIT MINIMUM CONDUCTOR CONDUCTOR REQUIRED CIRCUIT ADJUSTED NEUTRAL <br /> WIRE GAUGE& GROUND WIRE DRAWN DATE 11/22/2023 <br /> WIRE ID WIRE TEMP DERATE CARRYING CONDUIT SIZE AMPACITY @ AMPACITY @ CONDUCTOR CONDUCTOR CONDUCTOR <br /> (°C) (90°C) CONDUCTORS FILL DERATE (TBD ON SITE) TYPE 90°C(A) 75°C(A) AMPACITY(A) AMPACITY @ 90°C(A) SIZE&TYPE SIZE&TYPE DRAWN BY HS <br /> 1 26 1 6 IN AIR N/A #10 AWG PV WIRE 40 35 17.63 40.00 NONE #6 AWG BARE Cu <br /> 2 26 1 6 0.8 3/4"METAL #10 THWN-2 40 35 17.63 32.00 NONE #10 THWN-2 SHEET NUMBER <br /> AC WIRE CACLULATION PV-04 <br /> 3 26 1 2 1 1"METAL #4 THWN-2 95 85 78.13 95.00 #4 THWN-2 #8 THWN-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.