My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1105 SUMNER LN 2024-06-06
>
Address Records
>
SUMNER LN
>
1105
>
1105 SUMNER LN 2024-06-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2024 7:36:25 AM
Creation date
5/28/2024 10:21:57 AM
Metadata
Fields
Template:
Address Document
Street Name
SUMNER LN
Street Number
1105
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IQBM and IQBA Microinverters <br /> INPUT 1 1 , <br /> Commonly used module pairings' w 260-460 295-500 <br /> Module compatibility 60-cell/120 half-cell,66-cell/132 half-cell and 72-cell/144 half-cell <br /> MPPT voltage range V 33-45 36-45 <br /> Operating range V 25-58 <br /> Min/max start voltage V 30/58 <br /> Max input DC voltage V 60 <br /> Max DC currentz[module Isc] A 15 <br /> Overvoltage class DC port II <br /> DC port backfeed current mA 0 <br /> PV array configuration 1x1 Ungrounded array;No additional DC side protection required;AC side protection requires max 20A per branch circuit <br /> OUTPUT 1' A: 1: <br /> Peak output power VA 330 366 <br /> Max continuous output power VA 325 349 <br /> Nominal(L-L)voltage/range3 V 240/211-264 <br /> Max continuous output current A 1.35 1.45 <br /> Nominal frequency Hz 60 <br /> Extended frequency range Hz 50-68 <br /> AC short circuit fault current over 2 <br /> 3 cycles Arms <br /> Max units per 20 A(L-L)branch circuit4 11 <br /> Total harmonic distortion <5% <br /> Overvoltage class AC port III <br /> AC port backfeed current mA 30 <br /> Power factor setting 1.0 <br /> Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging <br /> Peak efficiency % 97.6 97.6 <br /> CEC weighted efficiency % 97 97.5 <br /> Night-time power consumption mw 60 <br /> MECHANICAL DATA <br /> Ambient temperature range -40°C to+60°C(-40°F to+140°F) <br /> Relative humidity range 4%to 100%(condensing) <br /> DC Connector type MC4 <br /> Dimensions(HxWxD) 212 mm(8.3")x 175 mm(6.9")x 30.2 mm(1.2") <br /> Weight 1.08 kg(2.38 lbs) <br /> Cooling Natural convection-no fans <br /> Approved for wet locations Yes <br /> Pollution degree PD3 <br /> Enclosure Class II double-insulated,corrosion resistant polymeric enclosure <br /> Environ.category/UV exposure rating NEMA Type 6/outdoor <br /> 1 CA Rule 21(UL 1741-SB),UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B,ICES-0003 Class B,CAN/CSA-C22.2 NO.107.1-01 <br /> Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014,NEC 2017,and NEC 2020 section <br /> 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according to <br /> manufacturer's instructions. <br /> (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/module-compatibility <br /> (2)Maximum continuous input DC current is 10.6A(3)Nominal voltage range can be extended beyond nominal if required by <br /> the utility.(4)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8MA-DS-0003-01-EN-US-2022-08-10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.