1� RESTROOM - FLAN (T1'F.) <br />SCALE 3/8" = I'-0" <br />MANEUVERIN6 CLEARANCE <br />AT DOOR - FRONT <br />APPROACH, PULL SIDE <br />60" <br />0 <br />TYP. CLEARANCE AT W.G, <br />30" <br />TYP. CLEAR FLOOR SPACE <br />S' Oil <br />GLEAR'NRNAR�ND <br />® RESTROOM (TYP.) - ELEVATION <br />SCALE 3/8" = I'-0" <br />7 <br />12 <br />17 <br />o� <br />© RESTROOM (TYP.) = ELEVATION <br />SCALE 3/8" = I'-0" <br />516NA6E NOTES: <br />WHITE LETTERS t SYMBOLS ON DARK BACKGROUND <br />TAMPER -RESISTANT, CONGEALED MECHANICAL FASTEN <br />TYPICAL "MEN" DOOR MOUNTED SIGN <br />MEN BRAILLE DOT5 (T(P) <br />ALL CHARACTERS AND LETTERING TO BE TACTILE PER <br />ICC AII1.1, 103.3 <br />WHERE A SIGN CONTAINING RAISED CHARACTERS AND BRAILLE 15 PROVIDED AT A DOOR, THE 516N SHALL BE <br />ALON651DE THE DOOR AT THE LATCH SIDE, U.N.O. PER Alli.l SECTION 103.3.11 <br />SIGNS CONTAINING RAISED CHARACTERS AND BRAILLE SHALL BE PERMITTED ON THE PUSH SIDE OF DOOR5 <br />WITH CLOSERS AND WITHOUT HOLD -OPEN DEVICES. <br />RAISED CHARACTERS SHALL BE 45 INCHES (1220 MM) MINIMUM ABOVE THE FLOOR, MEASURED TO THE BASELINE <br />OF THE LOWEST RAISED CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE THE FLOOR, MEASURED TO THE <br />BASELINE OF THE H16HE5T RAISED CHARACTER. AIIT.I SECTION 103.3.10 <br />REFER AL50 TO DOOR 516NA6E 4 LOCATION, 3/A-6.1 <br />2� RESTROOM/TAGTI L<E S I ONAOE <br />FREE HANGING COUNTERTOP <br />SUPPORT BRACKETS AT EACH 5TUD <br />LL <br />PLAN <br />FREE HANGING COUNTERTOP <br />SUPPORT BRACKETS <br />FRONT <br />e <br />WALL <br />m <br />FRa HANGING GO NTERTOP <br />SUPPORT BRACKETS <br />PLYWOOD COUNTERTOP BASE <br />TOP, APRON, AND 510M <br />k <br />SECTION <br />SEMI -COUNTERTOP SINK SUFFORT <br />0 RESTROOM (TYF.) - ELEVATION <br />SCALE 3/8" = 1'-0" <br />RESTROOM (TYP.) - ELEVATION <br />- EL_EVATION <br />SCALE 3/8" = 1'-0" <br />PLAN NOTES / KEYNOTES <br />1O TOILET ROOM FLOORS SHALL HAVE A SMOOTH, HARD, NON-AI35ORBANT SURFACE AT ALL WALL5 AND CASEWORK KICK SPACES <br />UNLESS OTHERWI5E NOTED. <br />2. PROVIDE COAT HOOKS WITHIN EACH TOILET ROOM. AT LEAST ONE SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES <br />SPECIFIED IN ICC MITI, 2009 SECTION 306. IF 5HELVE5 ARE PROVIDED, THEY SHALL BE INSTALLED 50 THE TOP OF THE SHELF 15 <br />40 INCHES (1015 MM) MINIMUM AND 4b INCHES MAXIMUM ABOVE THE FLOOR. ICC AII1.1, 2009 SEC. 603.4 <br />3. OPERABLE PARTS ON DRYING EQUIPMENT, TOWEL OR CLEAN51% PRODUCT DISPENSERS, AND DISPOSAL FIXTURES SHALL COMPLY <br />WITH ICC AII1.1 SECTION 309; THE MAXIMJM REACH HEIGHT SHALL BE 48 INCHE5 (1220 FH FOR UNOBSTRUCTED REACH DEPTHS NOT <br />MORE THAN 10 INCHES. <br />O4 FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH ICC AII1.1 <br />SECTION SN, EXCEPT THE MAXIMUM HEIGHT ABOVE THE FLOOR SHALL BE 44 INCHES. FLUSH CONTROLS SHALL BE LOCATED ON THE <br />OPEN SIDE OF THE WATER CLOSET. ICC AIIT.I SECTION 604.6. <br />5. CONTRACTOR 15 TO PROVIDE BACKING BETWEEN THE STUDS AS REQUIRED FOR ALL ACCESSORY ITEMS, INCLUDING THOSE NOT IN <br />CONTRACT. BALKING FOR 300 # LIVE LOAD. <br />6. ALL EXPOSED WIREMOLD, PLU&MOLD, ELECTRICAL ACCESS PANELS, ELT. ARE TO RECEIVE PAINT (THE SAME COLOR AS THE <br />ADJACENT WALL COLOR). <br />O RESTROOM WAINSCOT: 60" HIGH TILE WITH SULLN05E AT TOP, U.N.O. SEE ELEVATIONS FOR LOCATIONS. <br />8. FREE STANDING TOILET TISSUE DISPENSER. <br />Og WALL MIRROR WITH BACKLIGHT. <br />10 GRAB BARS SHALL BE INSTALLED AT ONE SIDE AND AT THE REAR OF THE WATER CLOSET. 6RAB BARS AND THEIR SUPPORTS <br />SHALL BE CAPABLE OF 5UPPORTIN6 NOT LESS THAN A 250 POUND LOAD. HEI6HT5 AND LOCATIONS TO COMPLY WITH IC , AIIT..1 <br />SECTION 6045 <br />11 NOT WATER PIPES AND DRAINS SHALL BE NRAPPED IN INSULATION OR OTHERWISE COVERED. ICC AIIT.I SECTION 606b <br />1� FAUCET CONTROL HANDLES SHALL COMPLY WITH REACH, HEIGHT AND OPERATION ACC.ORDIN6 TO AIIT.I SEC. 305 AND 309. <br />HAND -OPERATED METERIN6 FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM. <br />13. ALL FIXTURES INSTALLED SHALL BE ADA COMPLIANT. <br />14 DOOR HARDWARE SHALL BE OF A TYPE THAT SHALL BE OPERABLE WITHOUT THE PEED TO GRASP, TW15T, OR TURN. <br />15 VERTICAL 6RAB BAR SHALL BE 16" MIN. IN LEN6TH SHALL BE MOUNTED WITH THE BOTTOM OF THE BAR LOCATED BETWEEN 39" AND <br />41" ABOVE THE FLOOR, AND WITH THE CENTER LINE OF THE BAR LOCATED BETWEEN 39" AND 41" FROM THE REAR WALL. <br />16. WHEN 6YP5UM BOARD 15 USED A5 A BASE FOR TILE OR HALL PANELS FOR TUBS, 5HOWER5, OR WATER CLOSET COMPARTMENT <br />WALLS, WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A SUBSTRATE WHEN INSTALLED. <br />17 AMERICAN STANDARD "MEZZO" SEMI -COUNTERTOP 51NK INSTALL PER MANUF. INSTRUCTIONS. FIXTURE AND COUNTERTOP <br />MUST ALLOW KNEE / TOE CLEARANCE AND MANOVERIN6 CLEARANCE AT DOOR PER AIIT.I. INSTALL 13" DEEP COUNTERTOP <br />WITH A 10" H16H APRON, AND 4" HIGH BACKSPLASH, MATERIAL PER FINISH PLAN, UNLE55 NOTED OTHERWISE. USE STEEL BRACKET <br />SUPPORTS ATTACHED TO FRAMING. SEE DETAILS AT 3/A-6.0. <br />1g AMERICAN STANDARD TOILET ADA COMPLIANT FIXTURE, FLOOR MOUNTED. USE KOHLER TRIPOINT DG lb GPF FLUSHOMETER OR <br />SIMILAR. SEE SPECIFIC PRODUCT SCHEDULE. <br />TOILET ROOM NOTES <br />• ACCESSIBLE TOILET ROOMS TO COMPLY At AA STATE REGULATIONS FOR BARRIER FREE DE516N AND THE REQUIREMENTS OF THE <br />2016 IBC AS AMENDED BY THE STATE OF WA5HIN6TON. <br />• TOILET ROOMS 5HALL BE PROVIDED WITH A MECHANICALLY OPERATED EXHAUST SYSTEM CAPABLE OF PROVIDING AN EXHAUST <br />CAPACITY OF 50 CFM FOR EACH WATER OL05ET OR URINAL WHERE THE SYSTEM 15 DESIGNED TO RUN CONTINUOUSLY OR TO CFM <br />FOR INTERMITTENT OPERATION, AT A WATER GAUGE OF 25. SUCH SYSTEMS SHALL BE VENTED DIRECTLY TO THE OUTSIDE, AND THE <br />POINT OF DISCHAR6E SHALL BE SEPARATED AT A DISTANCE OF 10' HORIZONTALLY OR AT LEAST V ABOVE ANY OFENIN6 INTO THE <br />EUILDIN6. <br />• EXHAUST FAN AND L16HT SHALL BE INTEGRALLY SWITCHED. <br />• NEW CONSTRUCTION TOILET ROOMS SHALL BE ACCESSIBLE TO OTHER -THAN -ABLE-BODIED PERSONS. THEY SHALL COMPLY WITH <br />5ECTION5 11012 AND 11092 OF THE 2018 IBC, AND SHALL BE IN ACCORDANCE WITH THE WA5HIN6TON STATE AMENDMENTS TO THE <br />2016 IBC. <br />• TOILET ROOMS FLOOR FINISH MATERIALS SHALL HAVE A SMOOTH, HARD, NON -ABSORBENT SURFACE. THE INTERSECTIONS OF SUCH <br />FLOORS WITH WALL5 SHALL HAVE A SMOOTH, HARD, NON -ABSORBENT VERTICAL BASE THAT EXTEN05 UPWARD ONTO THE WALL5 <br />NOT LESS THAN 4 INCHES. IBC SEC. 1209.2.1 <br />• WALL5 AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, <br />NONA135ORBENT SURFACE, TO A HE16HT OF NOT LE55 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL <br />ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE THAT 15 NOT ADVERSELY AFFECTED BY MOISTURE. <br />ACCESSORIES SUCH A5 GRAB BARS, TOWEL BARS, PAPER DISPENSERS AND SOAP DISHES, PROVIDED ON OR WITHIN WALL5, 5HALL <br />BE INSTALLED AND SEALED TO PROTECT STRUCTURAL ELEMENTS FROM MOISTURE. IBC SEC. 12OU2 <br />• WHERE THE ROOM 15 FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYIN6 WITH SECTION 505.3 15 PROVIDED WITHIN THE <br />ROOM BEYOND THE ARC, OF THE DOOR SWING, THE DOOR SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 60322. <br />2-712 HEKTT <br />TENANT <br />I MPROVEMENT <br />2-112 HEWITT AVE. <br />EVERETT, M. 118201 <br />U <br />k, <br />O <br />V <br />cd <br />2515 ROOrl -ELLER AVE <br />EVERETT, WA 98201 <br />PHONE: 425.317.5017 <br />FAX: 425.31 "1.545G <br />s REGI5TERED m ARGHITEGT <br />s*e,re of vu.SNlb�b�NS <br />SCALE: AS NOTED <br />155UE DATE: 12/06/25 <br />DRAWN: SC/MC <br />CHECKED: SH <br />©THIS PLAN AND DESIGN 15 AND REMAINS <br />THE PROPERTY OF THE ARCHITECTS AND <br />MAY NOT BE USED WITHOUT PRIOR <br />CONSENT FROM THE ARCHITECT <br />FOR PERMIT <br />ADA TOILET ROOM <br />A-6.0 <br />