1� RESTROOM - FLAN (T1'F.)
<br />SCALE 3/8" = I'-0"
<br />MANEUVERIN6 CLEARANCE
<br />AT DOOR - FRONT
<br />APPROACH, PULL SIDE
<br />60"
<br />0
<br />TYP. CLEARANCE AT W.G,
<br />30"
<br />TYP. CLEAR FLOOR SPACE
<br />S' Oil
<br />GLEAR'NRNAR�ND
<br />® RESTROOM (TYP.) - ELEVATION
<br />SCALE 3/8" = I'-0"
<br />7
<br />12
<br />17
<br />o�
<br />© RESTROOM (TYP.) = ELEVATION
<br />SCALE 3/8" = I'-0"
<br />516NA6E NOTES:
<br />WHITE LETTERS t SYMBOLS ON DARK BACKGROUND
<br />TAMPER -RESISTANT, CONGEALED MECHANICAL FASTEN
<br />TYPICAL "MEN" DOOR MOUNTED SIGN
<br />MEN BRAILLE DOT5 (T(P)
<br />ALL CHARACTERS AND LETTERING TO BE TACTILE PER
<br />ICC AII1.1, 103.3
<br />WHERE A SIGN CONTAINING RAISED CHARACTERS AND BRAILLE 15 PROVIDED AT A DOOR, THE 516N SHALL BE
<br />ALON651DE THE DOOR AT THE LATCH SIDE, U.N.O. PER Alli.l SECTION 103.3.11
<br />SIGNS CONTAINING RAISED CHARACTERS AND BRAILLE SHALL BE PERMITTED ON THE PUSH SIDE OF DOOR5
<br />WITH CLOSERS AND WITHOUT HOLD -OPEN DEVICES.
<br />RAISED CHARACTERS SHALL BE 45 INCHES (1220 MM) MINIMUM ABOVE THE FLOOR, MEASURED TO THE BASELINE
<br />OF THE LOWEST RAISED CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE THE FLOOR, MEASURED TO THE
<br />BASELINE OF THE H16HE5T RAISED CHARACTER. AIIT.I SECTION 103.3.10
<br />REFER AL50 TO DOOR 516NA6E 4 LOCATION, 3/A-6.1
<br />2� RESTROOM/TAGTI L<E S I ONAOE
<br />FREE HANGING COUNTERTOP
<br />SUPPORT BRACKETS AT EACH 5TUD
<br />LL
<br />PLAN
<br />FREE HANGING COUNTERTOP
<br />SUPPORT BRACKETS
<br />FRONT
<br />e
<br />WALL
<br />m
<br />FRa HANGING GO NTERTOP
<br />SUPPORT BRACKETS
<br />PLYWOOD COUNTERTOP BASE
<br />TOP, APRON, AND 510M
<br />k
<br />SECTION
<br />SEMI -COUNTERTOP SINK SUFFORT
<br />0 RESTROOM (TYF.) - ELEVATION
<br />SCALE 3/8" = 1'-0"
<br />RESTROOM (TYP.) - ELEVATION
<br />- EL_EVATION
<br />SCALE 3/8" = 1'-0"
<br />PLAN NOTES / KEYNOTES
<br />1O TOILET ROOM FLOORS SHALL HAVE A SMOOTH, HARD, NON-AI35ORBANT SURFACE AT ALL WALL5 AND CASEWORK KICK SPACES
<br />UNLESS OTHERWI5E NOTED.
<br />2. PROVIDE COAT HOOKS WITHIN EACH TOILET ROOM. AT LEAST ONE SHALL BE LOCATED WITHIN ONE OF THE REACH RANGES
<br />SPECIFIED IN ICC MITI, 2009 SECTION 306. IF 5HELVE5 ARE PROVIDED, THEY SHALL BE INSTALLED 50 THE TOP OF THE SHELF 15
<br />40 INCHES (1015 MM) MINIMUM AND 4b INCHES MAXIMUM ABOVE THE FLOOR. ICC AII1.1, 2009 SEC. 603.4
<br />3. OPERABLE PARTS ON DRYING EQUIPMENT, TOWEL OR CLEAN51% PRODUCT DISPENSERS, AND DISPOSAL FIXTURES SHALL COMPLY
<br />WITH ICC AII1.1 SECTION 309; THE MAXIMJM REACH HEIGHT SHALL BE 48 INCHE5 (1220 FH FOR UNOBSTRUCTED REACH DEPTHS NOT
<br />MORE THAN 10 INCHES.
<br />O4 FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH ICC AII1.1
<br />SECTION SN, EXCEPT THE MAXIMUM HEIGHT ABOVE THE FLOOR SHALL BE 44 INCHES. FLUSH CONTROLS SHALL BE LOCATED ON THE
<br />OPEN SIDE OF THE WATER CLOSET. ICC AIIT.I SECTION 604.6.
<br />5. CONTRACTOR 15 TO PROVIDE BACKING BETWEEN THE STUDS AS REQUIRED FOR ALL ACCESSORY ITEMS, INCLUDING THOSE NOT IN
<br />CONTRACT. BALKING FOR 300 # LIVE LOAD.
<br />6. ALL EXPOSED WIREMOLD, PLU&MOLD, ELECTRICAL ACCESS PANELS, ELT. ARE TO RECEIVE PAINT (THE SAME COLOR AS THE
<br />ADJACENT WALL COLOR).
<br />O RESTROOM WAINSCOT: 60" HIGH TILE WITH SULLN05E AT TOP, U.N.O. SEE ELEVATIONS FOR LOCATIONS.
<br />8. FREE STANDING TOILET TISSUE DISPENSER.
<br />Og WALL MIRROR WITH BACKLIGHT.
<br />10 GRAB BARS SHALL BE INSTALLED AT ONE SIDE AND AT THE REAR OF THE WATER CLOSET. 6RAB BARS AND THEIR SUPPORTS
<br />SHALL BE CAPABLE OF 5UPPORTIN6 NOT LESS THAN A 250 POUND LOAD. HEI6HT5 AND LOCATIONS TO COMPLY WITH IC , AIIT..1
<br />SECTION 6045
<br />11 NOT WATER PIPES AND DRAINS SHALL BE NRAPPED IN INSULATION OR OTHERWISE COVERED. ICC AIIT.I SECTION 606b
<br />1� FAUCET CONTROL HANDLES SHALL COMPLY WITH REACH, HEIGHT AND OPERATION ACC.ORDIN6 TO AIIT.I SEC. 305 AND 309.
<br />HAND -OPERATED METERIN6 FAUCETS SHALL REMAIN OPEN FOR 10 SECONDS MINIMUM.
<br />13. ALL FIXTURES INSTALLED SHALL BE ADA COMPLIANT.
<br />14 DOOR HARDWARE SHALL BE OF A TYPE THAT SHALL BE OPERABLE WITHOUT THE PEED TO GRASP, TW15T, OR TURN.
<br />15 VERTICAL 6RAB BAR SHALL BE 16" MIN. IN LEN6TH SHALL BE MOUNTED WITH THE BOTTOM OF THE BAR LOCATED BETWEEN 39" AND
<br />41" ABOVE THE FLOOR, AND WITH THE CENTER LINE OF THE BAR LOCATED BETWEEN 39" AND 41" FROM THE REAR WALL.
<br />16. WHEN 6YP5UM BOARD 15 USED A5 A BASE FOR TILE OR HALL PANELS FOR TUBS, 5HOWER5, OR WATER CLOSET COMPARTMENT
<br />WALLS, WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A SUBSTRATE WHEN INSTALLED.
<br />17 AMERICAN STANDARD "MEZZO" SEMI -COUNTERTOP 51NK INSTALL PER MANUF. INSTRUCTIONS. FIXTURE AND COUNTERTOP
<br />MUST ALLOW KNEE / TOE CLEARANCE AND MANOVERIN6 CLEARANCE AT DOOR PER AIIT.I. INSTALL 13" DEEP COUNTERTOP
<br />WITH A 10" H16H APRON, AND 4" HIGH BACKSPLASH, MATERIAL PER FINISH PLAN, UNLE55 NOTED OTHERWISE. USE STEEL BRACKET
<br />SUPPORTS ATTACHED TO FRAMING. SEE DETAILS AT 3/A-6.0.
<br />1g AMERICAN STANDARD TOILET ADA COMPLIANT FIXTURE, FLOOR MOUNTED. USE KOHLER TRIPOINT DG lb GPF FLUSHOMETER OR
<br />SIMILAR. SEE SPECIFIC PRODUCT SCHEDULE.
<br />TOILET ROOM NOTES
<br />• ACCESSIBLE TOILET ROOMS TO COMPLY At AA STATE REGULATIONS FOR BARRIER FREE DE516N AND THE REQUIREMENTS OF THE
<br />2016 IBC AS AMENDED BY THE STATE OF WA5HIN6TON.
<br />• TOILET ROOMS 5HALL BE PROVIDED WITH A MECHANICALLY OPERATED EXHAUST SYSTEM CAPABLE OF PROVIDING AN EXHAUST
<br />CAPACITY OF 50 CFM FOR EACH WATER OL05ET OR URINAL WHERE THE SYSTEM 15 DESIGNED TO RUN CONTINUOUSLY OR TO CFM
<br />FOR INTERMITTENT OPERATION, AT A WATER GAUGE OF 25. SUCH SYSTEMS SHALL BE VENTED DIRECTLY TO THE OUTSIDE, AND THE
<br />POINT OF DISCHAR6E SHALL BE SEPARATED AT A DISTANCE OF 10' HORIZONTALLY OR AT LEAST V ABOVE ANY OFENIN6 INTO THE
<br />EUILDIN6.
<br />• EXHAUST FAN AND L16HT SHALL BE INTEGRALLY SWITCHED.
<br />• NEW CONSTRUCTION TOILET ROOMS SHALL BE ACCESSIBLE TO OTHER -THAN -ABLE-BODIED PERSONS. THEY SHALL COMPLY WITH
<br />5ECTION5 11012 AND 11092 OF THE 2018 IBC, AND SHALL BE IN ACCORDANCE WITH THE WA5HIN6TON STATE AMENDMENTS TO THE
<br />2016 IBC.
<br />• TOILET ROOMS FLOOR FINISH MATERIALS SHALL HAVE A SMOOTH, HARD, NON -ABSORBENT SURFACE. THE INTERSECTIONS OF SUCH
<br />FLOORS WITH WALL5 SHALL HAVE A SMOOTH, HARD, NON -ABSORBENT VERTICAL BASE THAT EXTEN05 UPWARD ONTO THE WALL5
<br />NOT LESS THAN 4 INCHES. IBC SEC. 1209.2.1
<br />• WALL5 AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD,
<br />NONA135ORBENT SURFACE, TO A HE16HT OF NOT LE55 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL
<br />ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE THAT 15 NOT ADVERSELY AFFECTED BY MOISTURE.
<br />ACCESSORIES SUCH A5 GRAB BARS, TOWEL BARS, PAPER DISPENSERS AND SOAP DISHES, PROVIDED ON OR WITHIN WALL5, 5HALL
<br />BE INSTALLED AND SEALED TO PROTECT STRUCTURAL ELEMENTS FROM MOISTURE. IBC SEC. 12OU2
<br />• WHERE THE ROOM 15 FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYIN6 WITH SECTION 505.3 15 PROVIDED WITHIN THE
<br />ROOM BEYOND THE ARC, OF THE DOOR SWING, THE DOOR SHALL NOT BE REQUIRED TO COMPLY WITH SECTION 60322.
<br />2-712 HEKTT
<br />TENANT
<br />I MPROVEMENT
<br />2-112 HEWITT AVE.
<br />EVERETT, M. 118201
<br />U
<br />k,
<br />O
<br />V
<br />cd
<br />2515 ROOrl -ELLER AVE
<br />EVERETT, WA 98201
<br />PHONE: 425.317.5017
<br />FAX: 425.31 "1.545G
<br />s REGI5TERED m ARGHITEGT
<br />s*e,re of vu.SNlb�b�NS
<br />SCALE: AS NOTED
<br />155UE DATE: 12/06/25
<br />DRAWN: SC/MC
<br />CHECKED: SH
<br />©THIS PLAN AND DESIGN 15 AND REMAINS
<br />THE PROPERTY OF THE ARCHITECTS AND
<br />MAY NOT BE USED WITHOUT PRIOR
<br />CONSENT FROM THE ARCHITECT
<br />FOR PERMIT