My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 74TH ST SW 2024-06-06
>
Address Records
>
74TH ST SW
>
607
>
607 74TH ST SW 2024-06-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2024 8:00:29 AM
Creation date
5/28/2024 1:10:57 PM
Metadata
Fields
Template:
Address Document
Street Name
74TH ST SW
Street Number
607
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lumio <br /> ENPHASE <br /> 1,08 and IQ8+ Microinverters <br /> INPUT DATA IDN UNITS 108-60-2-US IOSPLUS-72-2-US <br /> Commonly used module pairings' W 235-350 235-440 <br /> Module compatibility _ To meet compatibility,PV modules must be within maximum input DC voltage and maximum module I,listed below. <br /> Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator <br /> MPPT voltage range V 27-37 27-45 <br /> Operating range V 16-48 16-58 <br /> Minimum/Maximum start voltage V 22/48 22/58 <br /> Maximum input DC voltage V 50 60 <br /> Maximum continuous input DC current A 10 12 VERSION <br /> Maximum input DC short-circuit current A 25 DESCRIPTION DATE REV <br /> Maximum module I A 20 <br /> INITIAL RELEASE 11/21/2023 UR <br /> Overvoltage class DC port - II <br /> DC port backfeed current mA 0 <br /> PV array configuration - 1.1 ungrounded array;no additional DC side protection required;AC side protection requires maximum 20 A per branch circuit. <br /> OUTPUT DATA f: .f 2 US IQ8PLUS-72-2-US <br /> Peak output power VA 245 300 <br /> Maximum continuous output power VA 240 290 <br /> Nominal grid voltage(L-L) V 240,split-phase(L-L),180° <br /> IQ8and I Q 8+ Microinverters Easy to install Minimum and Maximum grid voltage2 V 211-264 <br /> • Lightweight and compact with plug- Maximum continuous output current A 1.0 1.21 <br /> Our newest IQ8 Microinverters are the industry's first microgrid-forming,software-defined and-play connectors <br /> microinverters with split-phase power conversion capability to convert DC power to AC Nominal frequency Hz 60 <br /> Power line communication(PLC) <br /> power efficiently.The brain of the semiconductor-based microinverter is our proprietary Extended frequency range Hz 47-68 <br /> components application-specific integrated circuit(ASIC),which enables the microinverter to operate in between compPROJECT NAME <br /> grid-tied or off-grid modes.This chip•s built usingtechnology with high-speed Faster installation with simple two-wire AC short-circuit fault current over <br /> three cycles Arms 2 <br /> digital logic and has superfast response times to changing loads and grid events,alleviating cabling <br /> constraints on battery sizing for home energy systems. Maximum units per 20 A(L-L)branch 16 13 Q <br /> circuit3 <br /> High productivity and reliability U) C N <br /> Produce power even when the grid is Total harmonic distortion % <5 D O <br /> F_ Enphase 1 down* Overvoltage class AC port - III '••UJ 3:� �.. "T(DID R W O <br /> of testing 0' I <br /> More than one million cumulative hours AC port backfeed current mA 30 [-- v) O — D W <br /> n^ <br /> Power factor setting - 1.0 Q N � - \ <br /> Class II double-insulated enclosure > 00 C) o/ �/ <br /> Grid-tied power factor(adjustable) - 0.85 leading...0.85 lagging > w <br /> Part of the Enphase Energy System, IQ8 Series Microinverters redefine Optimized for the latest high-powered <br /> IQ8 Series Microinverters integrate with the reliability standards with more than one PV modules Peak efficiency % 97.7 = Q m <br /> IQ Battery,IQ Gateway,and the million cumulative hours of power-on CEC weighted efficiency % 97 w < � o 03 <br /> Enphase App monitoring and analysis testing,enabling an industry-leading <br /> Microgrid-forming [' <br /> Nighttime power consumption mW 23 25 <br /> software. limited warranty of up to 25 years. C) z <br /> Compliant with the latest advanced MECHANICAL DATA U _ <br /> grid support** � J U <br /> Ambient temperature range -40°C to 60°C(-40°F to 140°F) Q w <br /> Remote automatic updates for the wb= LJJ CD Z <br /> latest grid requirements Relative humidity range 4%to 100%(condensing) w r1 =) � w <br /> \ L <br /> CERTIFIED Configurable to support a wide range DC connector type MC4 < <br /> of grid profiles Dimensions(H•W•D) 212 mm(8.3 in)•175 mm(6.9 in)•30.2 mm(1.2 in) /w o <br /> Connect PV modules quickly and easily IQ8 Series Microinverters are UL Listed Meet CA Rule 21(UL 1741-SA)and IEEE® Weight 1.08 kg(2-38 lbs) <br /> - <br /> to IQ8 Series Microinverters using the as PV rapid shutdown equipment and 1547:2018(UL 1741-SB 3 Ed.) <br /> included Q-DCC-2 adapter cable with conform with various regulations,when Cooling Natural convection-no fans <br /> plug-and-play MC4 connectors. installed according to the manufacturer's NOTE: Approved for wet locations Yes <br /> instructions. <br /> IQ8 Microinverters cannot be mixed with Pollution degree PD3 SHEET NAME <br /> previous generations of Enphase microinverters <br /> (I07 Series,I06 Series,and so on)in the same Enclosure Class II double-insulated,corrosion-resistant polymeric enclosure <br /> system. SPEC SHEETS <br /> IQ Gateway is required to change the default Environmental category/UV exposure rating NEMA Type 6/Outdoor <br /> "Meets UL 1741 only when installed with IQ System Controller 2. grid profile at the time of installation to meet <br /> **IQ8 and IQ8-support split-phase,240 V installations only. local Authority Having Jurisdiction(AHJ) SHEET SIZE <br /> requirements. <br /> ) <br /> 0 2023 Enphase Energy.All rights reserved.Enphase,thee and CC logos,IQ,and certain other marks listed at (1Nrangeo enforced DC/AC ratio. ANSI B <br /> (2)Nominal voltage range can be extended beyond nominal if required by the utility. <br /> https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy,Inc.in the US and other countries.Data subject to change. IQBSP-12A-DSH-00207-2.0-EN-US-2023-10-13 (3)Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. IQ8SP-12A-DSH-00207-2.0-EN-US-2023-10-13 <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.