Laserfiche WebLink
• GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION,LOAD CENTER,AND/OR SOLAR MODULE SPECIFICATIONS <br /> DISCONNECTS.DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ AMBIENT TEMPERATURE SPECIFICATIONS TEMPERATURE <br /> (AUTHORITY HAVING JURISDICTION).PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLE VMP IMP VOC ISC #OF Lumio <br /> CODES. MANUFACTURER/MODEL# (V) (A) (V) (A) COEFFICIENT MODULES <br /> • WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN CONDUCTOR OF Voc <br /> RECORD AMBIENT TEMP TEMPERATURE HANWHA QCELLS Q.PEAK DUO u <br /> TO INVERTER. LOW TEMP (HIGH TEMP 2%) 38.09 10.50 45.55 11.07 -0.27/o/K 13 <br /> • PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE RATE BLK ML-G10+/t(400W) <br /> PROTECTED IN A CONDUIT,RACEWAY,OR ARMORED PROTECTIVE SHEATHING(NEC 250.64). MODULE DIMENSION 74.0"L x 41.1"W x 1.26"D <br /> • THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE -5° 26' 90' <br /> NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. <br /> • ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC INVERTER SPECIFICATIONS <br /> 300.6 C1,310.8 D). SERVICE INFO. UTILITY METER NO: 320581 NOMINAL OUTPUT NOMINAL OUTPUT <br /> • ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP. MANUFACTURER/MODEL# QUANTITY VOLTAGE CURRENT <br /> • ALL CONDUIT SHALL BE EMT 3/4"IN DIAMETER UNLESS OTHERWISE STATED. UTILITY PROVIDER: SNOPUD NOTE-EQUIPMENT RATED AT 75 DEGREES ENPHASE ENERGY <br /> MAIN SERVICE VOLTAGE: 240V 13 240 VAC 1.21A <br /> MAIN PANEL BRAND: EATON IQ8PLUS-72-2-US <br /> MAIN SERVICE PANEL: (E)225A NOTE: <br /> MAIN CIRCUIT BREAKER RATING: (E)200A 3/4"OR GREATER EMT CONDUIT NOTE:THE AC DISCONNECT IS LOCATED <br /> MAIN SERVICE LOCATION: NORTH-EAST RUN (7/8"ABOVE ROOF SURFACE) WITHIN 1OFT OF UTILITY METER <br /> SERVICE FEED SOURCE: UNDERGROUND <br /> AC DISCONNECT SHALL BE LOCATED INTERCONNECTION <br /> WITHIN 10'OF UTILITY METER BI-DIRECTIONAL 120%RULE-NEC 705.12(B)(3)(2) <br /> VERSION <br /> UTILITY METER <br /> 1-PHASE,3-W, UTILITY FEED+SOLAR BACKFEED DESCRIPTION DATE REV <br /> 120V/24OV,60Hz 200A+20A=220A INITIAL RELEASE 11/21/2023 UR <br /> BUSS RATING x 120% <br /> (N)ENPHASE IQ 225A x 120%=270A <br /> 13 MICRO-INVERTERS IN BRANCH#1 COMBINER BOX 4 <br /> X2-IQ-AM 1-240-4 <br /> (IEEE1547:2018)[240V] <br /> L �f <br /> - I - I -LI <br /> I 10A/15A <br /> --- (N)JUNCTION BOX (N)30A NON-FUSED,AC <br /> DISCONNECT,240 VAC (E)MAIN <br /> I SERVICE PANEL, <br /> I 20A 200AE{ 225A RATED, <br /> (13)ENPHASE ENERGY I L1 L1 120/240V <br /> IQ8PLUS-72-2-US L2----C2 (E)MAIN BREAKER PROJECT NAME <br /> MICRO-INVERTERS(240V) j L1 L1 200A/2P,240V <br /> (LOCATED UNDER EACH PANEL) L2 L2 <br /> 71Q-GATEWAYTERMINATOR CAP ON LAST CABLE I MN N o Q <br /> CONNECTOR Q-CABLE(TYP) I r --- - G - - - 20A/2P U) O CV <br /> 7 <br /> I m (N)20A/2P PV N <br /> L-- G ❑� I BREAKER IY C:) LLI <br /> L--------- -- I— coN O D w< � <br /> L - � Coo > <br /> - - I 3: (j) Q c) 0LU w <br /> A <br /> C EXISTING < Z: 00 C5 00 <br /> B <br /> SYSTEM <br /> GROUNDING w ~ \� 3 O 2i <br /> J � I'-- >_ Z:) <br /> SYSTEM SIZE:-13 x 40OW=5.200 kWDC U z <br /> 13 x 290VA=3.770 kWAC Q O LL] J U <br /> LLI cD [)� z ~ U <br /> X > Q � 2 LU <br /> Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire LU Q O <br /> Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type <br /> A OPEN AIR 1 12 AWG Q Cable 90°C 30 1.0 N/A 30.00 13 1.21 1.25 19.66 06 AWG BARE CU <br /> SHEET NAME <br /> B 3/4" EMT 2 12 AWG THWN-2 90°C 30 1.0 0.80 24.00 13 1.21 1.25 19.66 06 AWG THWN-2 ELECTRICAL LINE <br /> DIAGRAM & <br /> C 3/4" EMT 3 10 AWG THWN-2 90°C 40 1.0 1.0 40.00 13 1.21 1.25 19.66 10 AWG THWN-2 CALCULATION <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> 1 ELECTRICAL LINE DIAGRAM WITH CALCULATION SHEET NUMBER <br /> SCALE: NTS PV-4 <br />