CONDUCTOR SCHEDULE <br /> SYSTEM NOTES: CONDUCTORS GROUND P 1. 14 - 405W ZNSHINE PANELS = 5.67 KW DC WIRES IN MINIMUM MINIMUM <br /> 2. 6 - HOYMILES HM-600 (590W) = 2.46A EACH @ 240V AC TAG ID CONDUIT WIRE SIZE TYPE,MATERIAL WIRE SIZE TYPE,MATERIAL <br /> 3. 2 - HOYMILES HM-300 (295W) = 1 .23 EACH @ 240V AC A' 6 #12 AWG THWN-2,CU #12AWG THWN-2,CU <br /> 4. TOTAL AC SYSTEM SIZE = 4.13 KW AC B 5 #12 AWG THWN-2,CU #12AWG THWN-2,CU urelight Powe <br /> C 3 1 #10 AWG THWN-2,CU #10 AWG THWN-2,CU <br /> PURELIGHT POWER <br /> NOTE: PV AC DISCONNECT LOCATED 3521 AVION DRIVE 200, <br /> MEDFORD,OR 97507504 <br /> WITHIN 10'OF THE MAIN BILLING METER UTILITY SERVICE CSLB:263801 <br /> PHONE:(541)816-4047 <br /> MINIMUM WIRE SIZES SPECIFIED.USE OF 120/240V EMAIL:ADMIN@PURELIGHTPOWER.COM <br /> LARGER WIRE IS ACCEPTABLE SINGLE PHASE <br /> VERSION <br /> DATE DESIGNER <br /> DES 1 11/4/23 PATRICK VILLAFUERTE <br /> REV 1 <br /> REV 2 <br /> REV 3 <br /> NEMA3R RATED (N)240V/PV 100A REV <br /> JUNCTION BOX: LOAD CENTER, (N)AC DISCONNECT REEFED WITH 4/0 AL Structural Stamp <br /> CIRCUIT 1: 7 MODULES-ZNSHINE ZXM7-SH108 SHALL COMPLY W/ 240V/30A NEMA 3R <br /> NEMA 3R RATED (E)200A RATED <br /> NEC 110.3&314.6 NON-FUSIBLE, (E)200A MAI MAIN SERVICE <br /> VISIBLE-LOCKABLE LABELED PANEL <br /> ° DU221 RB <br /> A B � (E)LOAD <br /> 2DA LLL y F:-i y <br /> ti ti ti <br /> F7HOYMILES INVERTERS, - AHJ Stamp <br /> REFER TO TABLE BELOW <br /> MA (N)PV OCPj, = <br /> CIRCUIT 2: 7 MODULES-ZNSHINE ZXM7-SH108 2P 30A GROUNDING <br /> LOAD-SIDE SOLAR OCP SYSTEM <br /> (OPPOSITE END OF THE MAIN <br /> DISCONNECT <br /> J ON THE BUSBAR-NEC <br /> 705.12(B)(3)(2) <br /> Q <br /> HOYMILES INVERTERS, <br /> REFER TO TABLE BELOW U ~ o <br /> o <br /> LU Q LU o 2 <br /> LU CD <br /> CIRCUIT 3:----MODULES-ZNSHINE ZXM7-SH108 Q o <br /> m <br /> LU C) CD Oz <br /> ° W 2 oo (.0 O <br /> LU O z <br /> O z U) o <br /> _ - - CL Q Z <br /> ti Lj <br /> CO Q J <br /> d7 <br /> HOYMILES INVERTERS, CD <br /> REFER TO TABLE BELOW <br /> BREAKER SIZE CALCS <br /> LOAD CALCS-TOTAL AMPS AVAILABLE IF LOAD SIDE BREAKER USED <br /> MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE BUS RATING 120% 1 1 TOTAL I MAINBREAKER1 MAX BREAKER SIZE <br /> 17.22A x 1.25 x 21.53A = 30A 200A X 1.2 = 240 200A = 40A <br /> COMBINER BOX PANEL SIZE CALCS SHEET NAME <br /> NUMBER OF MICROINVERTER NUMBER OF NOMINAL OUTPUT COMBINED ELECTRICAL <br /> CIRCUIT# MODULES TYPE MICROINVERTERS CURRENT TOTAL 125% TOTAL TOTAL BREAKER SIZE DIAGRAM <br /> CIRCUIT 1 1 of 3 1 1 X 1.23A = 1.23A x 1.25 = 1.54A <br /> CIRCUIT 1 (2 of 3) 6 HM- N 3 X 2.46A 7.38A x 1.25 = 9.23A = 10.76A = 20A SHEET NUMBER <br /> CIRCUIT 2(1 of 3) 1 HM-30ON 1 X 1.23A = 1.23A x 1.25 = 1.54A = 10.76A = 20A PV-5 <br /> CIRCUIT 2(2 of 3) 6 HM-60ON 3 X 2.46A = 7.38A x 1.25 = 9.23A <br />
The URL can be used to link to this page
Your browser does not support the video tag.