Laserfiche WebLink
PHOTOVOLTAIC ROOF MOUNT SYSTEM 1 <br /> 14 MODULES-ROOF MOUNTED - 5.67 kWDC, 4 . 13 kWAC <br /> 707 93RD ST SE , EVERETT, WA 98208 urelight (Powe <br /> AERIAL VIEW DESIGN CRITERIA PPOWER <br /> 352MEDFORD,1 AVION DRIVE STE 200, <br /> MEDFORD,OR 97504 <br /> CSLB:263801 <br /> ROOF TYPE: ASPHALT SHINGLE PHONE:(541)816-4047 <br /> NUMBER OF LAYERS: 1 EMAIL:ADMIN@PURELIGHTPOWER.COM <br /> ROOF FRAMING:2X4 @ 24" OC. PRE ENGINEERED TRUSSES VERSION <br /> • NUMBER OF STORIES: 1 <br /> WIND EXPOSURE: B DATE DESIGNER <br /> RISK CATEGORY: II DES 1 11/4/23 PATRICK VILLAFUERTE <br /> OCCUPANCY: R-3 RESIDENTIAL REV 1 <br /> REV 2 <br /> REV 3 <br /> REV 4 <br /> SHEET INDEX OOR Jo/,VC, Structural Stamp <br /> PV-0 COVER PAGE of WASy/� S <br /> PV-1 SITE PLAN <br /> PV-2 ROOF PLAN F 2 <br /> PV-3 ATTACHMENT DETAIL <br /> 410, PV-4 CIRCUIT DIAGRAM <br /> PV-5 ELECTRICAL DIAGRAM ° 201148 8 _ <br /> ' PV-6 ELECTRICAL CALCULATIONS <br /> PV-7 WARNING LABELS �SS/ONALEN� <br /> PV-8 PLACARD GENERAL NOTES 11/06/2023 AHJ Stamp <br /> STRUCTURAL ONLY <br /> 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY <br /> DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY <br /> ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES <br /> • SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. <br /> THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, <br /> VICINITY MAP 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS & RULES OF THE <br /> THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH Q <br /> BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. 3 p <br /> (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY U) o <br /> 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT w z LU N <br /> FOI}eS HII LABORATORY SHALL LIST ALL OF WORK. Q LU o U) <br /> EQUIPMENT IN COMPLIANCE WITH 3. CONTRACTOR IS RESPONSIBLE FOR ALL z � > o 2 <br /> UnjIICU ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA m w o o O <br /> 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, w � rn o O <br /> STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. p z I--- o <br /> INTO BOXES AS REQUIRED BY UL LISTING 4. SYSTEM IS GRID INTERACTIVE/INTERTIED 0� z <br /> 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER-CONDITIONING w <br /> AT THE UL-LISTED LOCATION PROVIDED INVERTER. Q <br /> Sn0 BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF r� <br /> CD <br /> UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. <br /> 6. MODULE FRAMES, RAIL, AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO <br /> SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. <br /> Eastmont GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED <br /> AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING <br /> Paine © 7. THE DC GROUNDING ELECTRODE SPECIFICATIONS. <br /> Field-Lake O CONDUCTOR SHALL BE SIZED 8. ALL WORK TO BE IN COMPLIANCE WITH SHEET NAME <br /> FLake <br /> field k Q ACCORDING TO ARTICLE 250.166B & THE INTERNATIONAL BUILDING CODES. <br /> Stic690.47. (IBC) COVER PAGE <br /> PICnIC� 1 iI'1 9. ALL ELECTRICAL WORK TO BE IN <br /> SILVER FIRS COMPLIANCE WITH THE NATIONAL <br /> Point-North ELECTRIC CODE (NEC). SHEET NUMBER <br /> Lynnwood I Mill Creek ( > <br /> PV-0 <br />