Laserfiche WebLink
SECTIONS AIM BE COMPLETED BY THE BUILDING DEPARTMENT IN TIIE JURISDICTION THE HOME WILL BE LOCATED. <br /> PLEASE CHECK All APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN —USING THEIR PROSPECTIVE <br /> RESIDENT BEDROOM DESIGNATIONS OF/1 Q C D C AND F AND CLASSIFICATION CODE 5, NS1 OR NS2. <br /> SECTIONBUILDING INSPECTOR'SINSPECTION <br /> R330.3 Sleeping Room Classification: Each sleeping room In an Adult family Home shall be classified as: <br /> Type S—where the means of egress contains stairs,elevators or platform lifts to evacuate residents to public area. <br /> Type N51 —where 1 means of egress at grade level (has no stairs)or ramp constructed compliant with R330.9 is provided to evacuate <br /> res dents to public arca. <br /> Type NS2—where 2 means of egress at grade level (both have no stairs)or ramps constructed compliant with 8330.9 are provided to <br /> c%acuate residents to public arca. <br /> SLEEPING ROOM A ❑Type S ❑Type NS1 —_ 173Type NS2 YES NO <br /> Closet door/s are readily openable from the inside 113 Yes JE3 No I❑N/A I Smoke alarm Is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.2.1: at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window ailowedl ❑ 1 ❑ <br /> SLEEPING ROOM B 113 Type S [3 Type NSl 10 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ❑Yes 113 No I ❑N/A I Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening;no steps under window allowed ❑ ❑ <br /> SLEEPING ROOM C F13-Type S E[3 Type NS1 10Type NS2 YES NO <br /> Closet door/s are readily openable from the inside 113 Yes 113No [:]N/A I Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high; at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.2.1: at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed ❑ 1 ❑ <br /> SLEEPING ROOM D 113 Type S 113 Type NS1 113Type NS2 I YES NO <br /> Closet door/s are readily openable from the inside ❑Yes ❑No ❑N/A I Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.2.1: at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowed ❑ 1 ❑ <br /> SLEEPING ROOM E 10Type S 10 Type NS1 10Type NS2 YES NO <br /> Closet door/s are readily openable from the inside ❑Yes 113 No 1 [3N/A I Smoke alarm is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high;at least 20"wide) ❑ ❑ <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44" above floor to clear opening; no steps under window allowedl ❑ 1 ❑ <br /> SLEEPING ROOM F 10 Type S Type NS1 113 Type NS2 I YES I NO <br /> Closet door/s are readily openable from the Inside 113 Yes JE3 No 113N/A Smoke alarm Is installed in the bedroom ❑ ❑ <br /> Bedroom door opens easily and quickly from the outside when locked ❑ ❑ <br /> Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20" wide) ❑ ❑ <br /> EXCEPT per R310.2.1: at-grade escape windows-may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill helght of 44" above floor to clear opening; no steps under window allowed ❑ ❑ <br /> Implementation Date: 2021 February 01 <br /> Updated: 2021 February <br />