Permit#: PW2309-032
<br /> Site Address: 1130 W MARINE VIEW DR STE A
<br /> Owner: EVERETT PORT OF
<br /> App.Date: 9/27/2023
<br /> Permit Type: PUBLIC WORKS
<br /> Description: NEW ACCESSIBLE RAMP AND
<br /> SELECT PARKING LOT
<br /> STRIPING STE A
<br /> GENERAL NOTES ARCH / INTERIOR ABBREVIATIONS BUILDING SUMMARY PROJECT TEAM
<br /> 3 or
<br /> 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT"GENERAL CONDITIONS,"AND BUILDING STANDARDS ADJ -ADJUSTABLE MATL -MATERIAL 1. PROJECT ADDRESS: TENANT: GENERAL CONTRACTOR: lz
<br /> AS PROVIDED BY THE BUILDING OWNER. AFF -ABOVE FINISH FLOOR MAX -MAXIMUM MARINE INSTITUTE MARITIME INSTITUTE DAVIS SCHUELLER INC 3 ALT -ALTERNATE MDF -MEDIUM DENSITY FIBERBOARD 1130W MARINE VIEW DR 1130 W MARINE VIEW DRIVE,SUITE A 4601 CHENNAULT BEACH RD SUITE 200 5�2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT ALUM -ALUMINUM MECH -MECHANICAL SUITE A EVERETT,WASHINGTON 98201 MUKILTEO,WASHINGTON 98275 ,' Q�i kTRADES. APC -ACOUSTIC PANEL CEILING MEZZ -MEZZANINE EVERETT,WASHINGTON 98201 ATTN:DAVE ABRAMS TEL:425.775.9400 _<
<br /> APPROX -APPROXIMATE MFR -MANUFACTURER EMAIL:DAVE@MARITIMEINSTITUTE.COM FAX:425.787.5201 1_„r.
<br /> 3. DO NOT SCALE DRAWINGS.CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. ARCH -ARCHITECTURAL MIN -MINIMUM 2. APPLICABLE CODES&ORDINANCES: ATTN:TRAVIS RICHARDS
<br /> ACT -ACOUSTIC CEILING TILE MISC -MISCELLANEOUS A. BUILDING CODES ARCHITECT/DESIGNER: EMAIL:TRICHARDS@DAVISSCHUELLER.COM APPROVED
<br /> 4, CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT AV -AUDIO VISUAL MTD -MOUNTED INTERNATIONAL BUILDING CODE-2018 WEAVER ARCHITECTS,INC. WA LICENSE:DAVISS1105PN
<br /> FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION.CHANGES SHOWN ON SHOP DRAWING BLDG -BUILDING MTL -METAL INTERNATIONAL EXISTING BUILDING CODE-2018 PIER 55 PUBLIC WORKS DEPARTMENT
<br /> ONLY WILL NOT SATISFY THIS REQUIREMENT. BOT -BOTTOM (N) -NEW WASHINGTON STATE ENERGY CODE COMMERCIAL-2018 1101 ALASKAN WAY,SUITE 300 PLUMBING ENGINEER: BY:THerman
<br /> B/S -BUILDING STANDARD N/A -NOT APPLICABLE B. REGULATIONS&ORDINANCES SEATTLE,WASHINGTON 98101 TBD-BIDDER DESIGN BUILD BY G.C. DATE:10113/2023
<br /> 5. ALL MODIFICATIONS,REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS CAB -CABINET NIC -NOT IN CONTRACT NFPA TEL: 206.262.9622 CITY OF EVERETT REVIEWED FOR PERMIT
<br /> AUTHORIZED IN WRITING BY OWNER AND/OR ARCHITECT. CL -CENTERLINE NTS -NOT TO SCALE C. ACCESSIBILITY ATTN:AMIE JOYCE MECHANICAL ENGINEER:
<br /> CLG -CEILING OC -ON CENTER INTERNATIONAL BUILDING CODE-2018 EMAIL:AMIEJ@WEAVERARCH.COM TBD-BIDDER DESIGN BUILD BY G.C.
<br /> 6. WITHIN FIVE(5)BUSINESS DAYS OF START OF CONSTRUCTION,THE CONTRACTOR SHALL NOTIFY IN CUR -CLEAR OFF -OFFICE ICC/ANSI 117.1 ACCESSIBLE&USABLE BUILDINGS AND FACILITIES-2009
<br /> WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE COL -COLUMN OR -OPPOSITE HAND STRUCTURAL ENGINEER ELECTRICAL ENGINEER: CI of Everett Permit Review
<br /> WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE CONC -CONCRETE OPNG -OPENING 3. GENERAL BUILDING DESCRIPTION: LUND OPSAHL TBD-BIDDER DESIGN BUILD BY G.C. ` City
<br /> SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES,PAYMENT OF RUSH FABRICATION OR CONE -CONFERENCE OVHD -OVERHEAD TYPE OF CONSTRUCTION:11-B 1215 FOURTH AVENUE,SUITE 1200 EVERETT Status:Approved as Noted
<br /> DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION,OR DELAY OF INSTALLATION OPTIONS TO BE AT DEMO -DEMOLITION P -PAINT FIRE RESISTIVE SYSTEM:NON-SPRINKLED W/SMOKE DETECTION SEATTLE,WASHINGTON 98161 FIRE/UFE SAFETY ENGINEER:
<br /> THE SOLE APPROVAL OF OWNER OR ARCHITECT. DEPT -DEPARTMENT PART -PARTITION OCCUPANCY TYPE:'B'OFFICE TEL 206.402.5156 TBD-BIDDER DESIGN BUILD BY G.C. 10/13/2023 7:44:15 AM
<br /> DF -DRINKING FOUNTAIN PERF -PERFORATED ATTN:CASEY MOORE
<br /> 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE DIA -DIAMETER PERIM -PERIMETER 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: EMAIL:CMOORE@LUNDOPSAHLCOM
<br /> WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. DIFF -DIFFUSER PERP -PERPENDICULAR SHAFT ENCLOSURES.NA
<br /> DIM -DIMENSION ELAM -PLASTIC LAMINATE EXIT STAIR ENCLOSURES:NA
<br /> 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY DTL -DETAIL PLYWD -PLYWOOD CORRIDORS:NA
<br /> CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK.DO NOT SCALE DW -DISHWASHER PT -PRESSURE TREATED
<br /> THE DRAWINGS. DWG -DRAWING PVC -POLYVINYLCHLORIDE 5. EXITS:
<br /> (E) -EXISTING QTY -QUATFRY APPROXIMATE AREA OF WORK/CONSTRUCTION:3,586 SQUARE FEET LEGAL DESCRIPTION
<br /> 9. THE USE OF WORD"PROVIDE"SHALL ALWAYS MEAN,"FURNISH AND INSTALL,CONNECT,OR SECURE"AS EA -EACH (N) -RELOCATED TOTAL APPROXIMATE SUITE AREA:3,586 SQUARE FEET
<br /> REQUIRED. EL -ELEVATOR RA -RETURN AIR SEE SHEET G.0.2 FOR OCCUPANT LOAD FACTOR
<br /> ELEC -ELECTRICAL RCP -REFLECTED CEILING PLAN PARCEL NUMBER:29051800102800
<br /> 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS ELEV -ELEVATION REC -RECESSED 6. PROJECT DESCRIPTION:
<br /> WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. EQ -EQUAL REF -REFERENCE NON-STRUCTURAL INTERIOR TENANT SPACE IMPROVEMENT.NEW PARTITIONS,INTERIOR DOOR& LEGAL DESCRIPTION:SECTION 18 TOWNSHIP 29 RANGE 05 QUARTER NE LOT D4 OF BSP FOR DIV 3 OF
<br /> EQUIP -EQUIPMENT REFR -REFIGERATOR EXTERIOR DOORS,FINISHES. PORT OF EV N MARINA BSP16-004 REC UND AFN 201708075002&AS CORR BY AFN 201812265002 BEING A
<br /> 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE.THIS SCHEDULE SHALL INCLUDE EXT -EXTERIOR REL -RELOCATE PTN OF NE1/4&NW1/4 SD SEC&TGW PTN VAC W MARINE VIEW DR AS DESC IN VAC ORD NO 3580-17 REC
<br /> DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS,AND START AND COMPLETION DATES OF EACH PHASE. FA -FIRE ALARM REV -REVISION OR REVISED 7, DEFERRED SUBMITTALS:MECHANICAL,PLUMBING,ELECTRICAL,LOW VOLTAGE,FIRE ALARM. UND AFN 201712190539,REFER TO 29051800102801 FOR BLDGS ONLY
<br /> THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. FD -FLOOR DRAIN RM -ROOM
<br /> FE -FIRE EXTINGUISHER RD -ROUGH OPENING ZONE:COMMERCIAL MU
<br /> 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE FEC -FIRE EXTINGUISHER CABINET RTD -RATED
<br /> TENANTS. FEE -FINISH FLOOR ELEVATION SCHED -SCHEDULE LUFIN -FINISH SF -SQUARE FEET/FOOT STREET MAP DRAWING INDEX LU
<br /> 13. ACCESS TO AND FROM THE PROJECT SITE,SPECIAL CONDITIONS,NOISY WORK,TIMING OF WORK, FLUOR -FLUORESCENT BHT -SHEET
<br /> INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES,RELOCATION OF EXISTING EQUIPMENT, FUR -FLOOR SIM -SIMILAR
<br /> CASEWORK,FIXTURES,FITTINGS,ETC.,MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. FO -FACE OF SPEC -SPECIFICATION g Q DRAWING ISSUED w
<br /> FCIC -FURNISHED BY CONTRACTOR, SPKR -SPRINKLER
<br /> 14. ADEQUATE CLEANUP,PROTECTION AND PLACEMENT OF ANY CEILING TILES AND/OR OTHER DISRUPTION INSTALLED BY CONTRACTOR SQ -SQUARE
<br /> TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT FDIC -FURNISHED BY OWNER,INSTALLED STD -STANDARD nn St 7 F N Z a¢
<br /> TENANT IN ORDER THATTHE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL BY CONTRACTOR STL -STEEL O _ u'_ o L11LIJ
<br /> CONTINUATION OF THEIR OFFICE HOURS. FOIO -FURNISHED BY OWNER,INSTALLED BY STOR -STORAGE 5
<br /> cc 13
<br /> OWNER STEL -STRUCTURAL (n>o
<br /> 15, EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR FTIC -FURNISHED BY TENANT,INSTALLED STRUC -STRUCTURAL f GENERAL LL1 W
<br /> SAID DAMAGE AT THEIR OWN EXPENSE.THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: BY CONTRACTOR SYMM -SYMMETRICAL Bayside Marine o X X G.0.0 COVER SHEET/PROJECT INFORMATION U Z
<br /> s oe;.,^ OC a
<br /> COMMON HALLWAYS,FREIGHT ELEVATOR VESTIBULES,ETC. FT -FIRE TREATED TBD -TO BE DETERMINED a CE
<br /> FLIER -FURRING TEL -TELEPHONE QQ CL Q
<br /> 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 31S -GOOD ONE SIDED TEMP -TEMPERED E ~ G F 2
<br /> ARCHITECTURAL/INTERIORS U
<br /> 32S -GOOD TWO SIDED THK -THICKNESS LU Z LU
<br /> X X A.0.1 SITE PLAN - LU a
<br /> 17, UPON COMPLETION OF ALL CONSTRUCTION,THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH GA -GAUGE TO -TOP OF O M
<br /> ONE SET OF"RECORD"AS-BUILT DRAWINGS. X X A.0.2 OCCUPANCY&EGRESS PLAN/SITE MODIFICATIONS O = Z m LU
<br /> GC -GENERAL CONTRACTOR TOS -TOP OF SLAB DE w r>
<br /> GL -GLASS TYP -TYPICAL Q- T LU
<br /> 18, ALL MATERIALS TO BE NEW ION. GWB -GYPSUM WALL BOARD ION -UNLESS OTHERWISE NOTED
<br /> GYP -GYPSUM UPS -UNINTERRUPTED POWER SUPPLY
<br /> 19. PATCH ALL DISTURBED AND/OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS HC -HANDICAPPED VCT -VINYL COMPOSITION TILE
<br /> REQUIRED FOR FINISHED APPEARANCE. HDW -HARDWARE VIF -VERIFY IN FIELD -F PROJECT ^^
<br /> HM -HOLLOUR W METAL(STEEL FRAME) W/ -WITH J l� III�� WSTATEO
<br /> RED
<br /> 20 FRAM NGGENERAL OR LIGHTTOXTURES,ER IS ONSIBLE LECTRICALOFIXTUURES,CASEWORK AND ALL OTHING ALL NECESSARY IER ITEMS REQUIRING NCLHE -NOLUDED OR INCLUDING WD -WOOD NG,BLOCKING,AND WC -WATER CLOSET LOCATION i,'ql„„it;I'��;I i''"("" CT
<br /> IT. INFO -INFORMATION W/O -WITHOUT
<br /> INSUL -INSULATION
<br /> 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. LAV -LAVATORY VER
<br /> LF -LINEAR FOOT NGTON
<br /> 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE
<br /> ARCHITECT'S REVIEW PRIOR TO INSTALLATION.SUBMIT TO ARCHITECT THREE(3)COPIES FOR REVIEW.
<br /> 07/19/25
<br /> 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK,MILLWORK AND ANY
<br /> OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION.SUBMIT TO ARCHITECT AT LEAST
<br /> THREE(3)COPIES FOR REVIEW. DEFINITIONS AND DIMENSIONS KEY PLAN / FLOOR PLATE: 1/16" = 11-011
<br /> 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY NO. ISSUE/REVISIONS DATE
<br /> PROVIDED AS IF DRAWN IN FULL. A. DEFINITIONSREVIEW SET 09.05.2023
<br /> 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE.THE LIST OFCONSTRUCTION WORK SHALL NOT PROCEED UNTIL THE PERMIT/CD SET 09.25.2023
<br /> ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST.THE ARCHITECT WILL DEFINE 1. "TYPICAL"OR'T'P"INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. BUILDING OWNER/REPRESENTATIVE HAVE GIVEN THEIR
<br /> THE INTENT OF ANY IN QUESTION. APPROVAL TO THESE CONSTRUCTION DOCUMENTS.
<br /> 2."SIMILAR"OR"SIM."INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE APPROVAL BY THESE PARTIES SHALL BE INTERPRETED AS
<br /> CHARACTERISTICS FOR THE CONDITION NOTED.
<br /> APPROVAL OF DRAWINGS FOR CONTENT,FINISH SELECTIONS,
<br /> SCOPE OF WORK,AND ALL DIMENSIONS REGARDED BY EITHER
<br /> 3."AS REQUIRED"INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE PARKAS BEING NECESSARY TO THEIR OPERATIONS,USE OF
<br /> THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. THE SPACE,FURNISHINGS,AND TENANT EQUIPMENT AND
<br /> FURNITURE INSTALLATIONS.
<br /> 4. "ALIGN"INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT,TRUE,AND CONSTRUCTION AND/OR INITIATION OF CONSTRUCTION,
<br /> SYMBOLS PLUMB RELATION ADJACENT MATERIALS. AUTHORIZED BY THE BUILDING OWNER FROM THESE
<br /> CONSTRUCTION DOCUMENTS,SHALL BE INTERPRETED BY THE
<br /> 5. "CLEAR"INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS. r DESIGNER AS APPROVAL IN FULL OF THESE CONSTRUCTION
<br /> DOCUMENTS BY THE BUILDING OWNER/REPRESENTATIVE.
<br /> ELEVATION REFERENCE SYMBOL INDICATES FINISHED B. DIMENSIONS: I °°
<br /> U SURFACES TO ALIGN
<br /> DETAIL ID 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING
<br /> DRAWING TITLE BAR CONSTRUCTION,CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED. I COVER SHEET/
<br /> L X.X.X R �LE
<br /> EEO
<br /> SHEET NO. 2.ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT,TRUER PLUMB. I rAREA OF WORK PROJECT INFORMATION
<br /> D DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. I I SUITE A
<br /> a. STRUCTURAL DRAWINGS
<br /> SECTION REFERENCE SYMBOL Ab. LARGE SCALE DETAILS c. SMALL SCALE DETAILS
<br /> DTL d. ENLARGED PLANS AND SECTIONS
<br /> SHT FLOOR ELEVATION SYMBOLS e. FLOOR PLANS
<br /> NOMINAL FLOOR
<br /> 3.MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS
<br /> DETAIL REFERENCE SYMBOL ELEVATION HEIGHT PROJECT NO 23-037-00
<br /> (ABOVE/BELOW) SHALL BE MAINTAINED. I I
<br /> DTL BUILDING SPACE/ROOM ID 4. FLOOR ELEVATIONS ARE INDICATED ATTHE FACE OF THE STRUCTURAL SLAB,UNLESS OTHERWISE I I DRAWN BY. RS G"O O
<br /> SHT ROOM - SPACE NAME NOTED. -� REVIEWED BY:PG/HW
<br /> COLUMN AND/OR GRID LINE SYMBOL 0 - SPACE NUMBER 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED r PERMITAGENCY
<br /> DIMENSION LINE: DOOR SYMBOL&NUMBER MATERIAL,UNLESS NOTED ABOVE FINISH FLOOR-"AFF".
<br /> 20' 0" 6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED
<br /> DOOR NUMBER ACOUSTIC CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES,UNLESS
<br /> OTHERWISE NOTED.
<br /> 1 _ _ DOCUMENT SHEET SYMBOL
<br /> 7. DOCUMENTS ARE DRAWN DIAGRAMATICALLY,AND SCALED DIMENSIONS ARE APPROXIMATE.
<br /> OKEYED SHEET NOTE/TAGDIMENSIONS SHALL INDICATE REQUIRED SIZE,CLEARANCES,AND RELATIONSHIPS ARE INDICATED
<br /> L ANGLE BY DIMENSIONS AS NOTED.
<br /> @p AT G1 GLAZING SYMBOL/TAG
<br /> CENTERLINE A - REVISION NUMBER/TAG
<br /> Dngmel areW l 21x.Er.seele emulee ecoomlogry n,
<br /> All IP-1.,&inlelleolual Property nQN,reservetl c 2023
<br />
|