Laserfiche WebLink
Permit#: PW2309-032 <br /> Site Address: 1130 W MARINE VIEW DR STE A <br /> Owner: EVERETT PORT OF <br /> App.Date: 9/27/2023 <br /> Permit Type: PUBLIC WORKS <br /> Description: NEW ACCESSIBLE RAMP AND <br /> SELECT PARKING LOT <br /> STRIPING STE A <br /> GENERAL NOTES ARCH / INTERIOR ABBREVIATIONS BUILDING SUMMARY PROJECT TEAM <br /> 3 or <br /> 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT"GENERAL CONDITIONS,"AND BUILDING STANDARDS ADJ -ADJUSTABLE MATL -MATERIAL 1. PROJECT ADDRESS: TENANT: GENERAL CONTRACTOR: lz <br /> AS PROVIDED BY THE BUILDING OWNER. AFF -ABOVE FINISH FLOOR MAX -MAXIMUM MARINE INSTITUTE MARITIME INSTITUTE DAVIS SCHUELLER INC 3 ALT -ALTERNATE MDF -MEDIUM DENSITY FIBERBOARD 1130W MARINE VIEW DR 1130 W MARINE VIEW DRIVE,SUITE A 4601 CHENNAULT BEACH RD SUITE 200 5�2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT ALUM -ALUMINUM MECH -MECHANICAL SUITE A EVERETT,WASHINGTON 98201 MUKILTEO,WASHINGTON 98275 ,' Q�i kTRADES. APC -ACOUSTIC PANEL CEILING MEZZ -MEZZANINE EVERETT,WASHINGTON 98201 ATTN:DAVE ABRAMS TEL:425.775.9400 _< <br /> APPROX -APPROXIMATE MFR -MANUFACTURER EMAIL:DAVE@MARITIMEINSTITUTE.COM FAX:425.787.5201 1_„r. <br /> 3. DO NOT SCALE DRAWINGS.CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. ARCH -ARCHITECTURAL MIN -MINIMUM 2. APPLICABLE CODES&ORDINANCES: ATTN:TRAVIS RICHARDS <br /> ACT -ACOUSTIC CEILING TILE MISC -MISCELLANEOUS A. BUILDING CODES ARCHITECT/DESIGNER: EMAIL:TRICHARDS@DAVISSCHUELLER.COM APPROVED <br /> 4, CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT AV -AUDIO VISUAL MTD -MOUNTED INTERNATIONAL BUILDING CODE-2018 WEAVER ARCHITECTS,INC. WA LICENSE:DAVISS1105PN <br /> FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION.CHANGES SHOWN ON SHOP DRAWING BLDG -BUILDING MTL -METAL INTERNATIONAL EXISTING BUILDING CODE-2018 PIER 55 PUBLIC WORKS DEPARTMENT <br /> ONLY WILL NOT SATISFY THIS REQUIREMENT. BOT -BOTTOM (N) -NEW WASHINGTON STATE ENERGY CODE COMMERCIAL-2018 1101 ALASKAN WAY,SUITE 300 PLUMBING ENGINEER: BY:THerman <br /> B/S -BUILDING STANDARD N/A -NOT APPLICABLE B. REGULATIONS&ORDINANCES SEATTLE,WASHINGTON 98101 TBD-BIDDER DESIGN BUILD BY G.C. DATE:10113/2023 <br /> 5. ALL MODIFICATIONS,REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS CAB -CABINET NIC -NOT IN CONTRACT NFPA TEL: 206.262.9622 CITY OF EVERETT REVIEWED FOR PERMIT <br /> AUTHORIZED IN WRITING BY OWNER AND/OR ARCHITECT. CL -CENTERLINE NTS -NOT TO SCALE C. ACCESSIBILITY ATTN:AMIE JOYCE MECHANICAL ENGINEER: <br /> CLG -CEILING OC -ON CENTER INTERNATIONAL BUILDING CODE-2018 EMAIL:AMIEJ@WEAVERARCH.COM TBD-BIDDER DESIGN BUILD BY G.C. <br /> 6. WITHIN FIVE(5)BUSINESS DAYS OF START OF CONSTRUCTION,THE CONTRACTOR SHALL NOTIFY IN CUR -CLEAR OFF -OFFICE ICC/ANSI 117.1 ACCESSIBLE&USABLE BUILDINGS AND FACILITIES-2009 <br /> WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE COL -COLUMN OR -OPPOSITE HAND STRUCTURAL ENGINEER ELECTRICAL ENGINEER: CI of Everett Permit Review <br /> WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE CONC -CONCRETE OPNG -OPENING 3. GENERAL BUILDING DESCRIPTION: LUND OPSAHL TBD-BIDDER DESIGN BUILD BY G.C. ` City <br /> SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES,PAYMENT OF RUSH FABRICATION OR CONE -CONFERENCE OVHD -OVERHEAD TYPE OF CONSTRUCTION:11-B 1215 FOURTH AVENUE,SUITE 1200 EVERETT Status:Approved as Noted <br /> DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION,OR DELAY OF INSTALLATION OPTIONS TO BE AT DEMO -DEMOLITION P -PAINT FIRE RESISTIVE SYSTEM:NON-SPRINKLED W/SMOKE DETECTION SEATTLE,WASHINGTON 98161 FIRE/UFE SAFETY ENGINEER: <br /> THE SOLE APPROVAL OF OWNER OR ARCHITECT. DEPT -DEPARTMENT PART -PARTITION OCCUPANCY TYPE:'B'OFFICE TEL 206.402.5156 TBD-BIDDER DESIGN BUILD BY G.C. 10/13/2023 7:44:15 AM <br /> DF -DRINKING FOUNTAIN PERF -PERFORATED ATTN:CASEY MOORE <br /> 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE DIA -DIAMETER PERIM -PERIMETER 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: EMAIL:CMOORE@LUNDOPSAHLCOM <br /> WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. DIFF -DIFFUSER PERP -PERPENDICULAR SHAFT ENCLOSURES.NA <br /> DIM -DIMENSION ELAM -PLASTIC LAMINATE EXIT STAIR ENCLOSURES:NA <br /> 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY DTL -DETAIL PLYWD -PLYWOOD CORRIDORS:NA <br /> CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK.DO NOT SCALE DW -DISHWASHER PT -PRESSURE TREATED <br /> THE DRAWINGS. DWG -DRAWING PVC -POLYVINYLCHLORIDE 5. EXITS: <br /> (E) -EXISTING QTY -QUATFRY APPROXIMATE AREA OF WORK/CONSTRUCTION:3,586 SQUARE FEET LEGAL DESCRIPTION <br /> 9. THE USE OF WORD"PROVIDE"SHALL ALWAYS MEAN,"FURNISH AND INSTALL,CONNECT,OR SECURE"AS EA -EACH (N) -RELOCATED TOTAL APPROXIMATE SUITE AREA:3,586 SQUARE FEET <br /> REQUIRED. EL -ELEVATOR RA -RETURN AIR SEE SHEET G.0.2 FOR OCCUPANT LOAD FACTOR <br /> ELEC -ELECTRICAL RCP -REFLECTED CEILING PLAN PARCEL NUMBER:29051800102800 <br /> 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS ELEV -ELEVATION REC -RECESSED 6. PROJECT DESCRIPTION: <br /> WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. EQ -EQUAL REF -REFERENCE NON-STRUCTURAL INTERIOR TENANT SPACE IMPROVEMENT.NEW PARTITIONS,INTERIOR DOOR& LEGAL DESCRIPTION:SECTION 18 TOWNSHIP 29 RANGE 05 QUARTER NE LOT D4 OF BSP FOR DIV 3 OF <br /> EQUIP -EQUIPMENT REFR -REFIGERATOR EXTERIOR DOORS,FINISHES. PORT OF EV N MARINA BSP16-004 REC UND AFN 201708075002&AS CORR BY AFN 201812265002 BEING A <br /> 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE.THIS SCHEDULE SHALL INCLUDE EXT -EXTERIOR REL -RELOCATE PTN OF NE1/4&NW1/4 SD SEC&TGW PTN VAC W MARINE VIEW DR AS DESC IN VAC ORD NO 3580-17 REC <br /> DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS,AND START AND COMPLETION DATES OF EACH PHASE. FA -FIRE ALARM REV -REVISION OR REVISED 7, DEFERRED SUBMITTALS:MECHANICAL,PLUMBING,ELECTRICAL,LOW VOLTAGE,FIRE ALARM. UND AFN 201712190539,REFER TO 29051800102801 FOR BLDGS ONLY <br /> THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. FD -FLOOR DRAIN RM -ROOM <br /> FE -FIRE EXTINGUISHER RD -ROUGH OPENING ZONE:COMMERCIAL MU <br /> 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE FEC -FIRE EXTINGUISHER CABINET RTD -RATED <br /> TENANTS. FEE -FINISH FLOOR ELEVATION SCHED -SCHEDULE LUFIN -FINISH SF -SQUARE FEET/FOOT STREET MAP DRAWING INDEX LU <br /> 13. ACCESS TO AND FROM THE PROJECT SITE,SPECIAL CONDITIONS,NOISY WORK,TIMING OF WORK, FLUOR -FLUORESCENT BHT -SHEET <br /> INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES,RELOCATION OF EXISTING EQUIPMENT, FUR -FLOOR SIM -SIMILAR <br /> CASEWORK,FIXTURES,FITTINGS,ETC.,MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. FO -FACE OF SPEC -SPECIFICATION g Q DRAWING ISSUED w <br /> FCIC -FURNISHED BY CONTRACTOR, SPKR -SPRINKLER <br /> 14. ADEQUATE CLEANUP,PROTECTION AND PLACEMENT OF ANY CEILING TILES AND/OR OTHER DISRUPTION INSTALLED BY CONTRACTOR SQ -SQUARE <br /> TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT FDIC -FURNISHED BY OWNER,INSTALLED STD -STANDARD nn St 7 F N Z a¢ <br /> TENANT IN ORDER THATTHE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL BY CONTRACTOR STL -STEEL O _ u'_ o L11LIJ <br /> CONTINUATION OF THEIR OFFICE HOURS. FOIO -FURNISHED BY OWNER,INSTALLED BY STOR -STORAGE 5 <br /> cc 13 <br /> OWNER STEL -STRUCTURAL (n>o <br /> 15, EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR FTIC -FURNISHED BY TENANT,INSTALLED STRUC -STRUCTURAL f GENERAL LL1 W <br /> SAID DAMAGE AT THEIR OWN EXPENSE.THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: BY CONTRACTOR SYMM -SYMMETRICAL Bayside Marine o X X G.0.0 COVER SHEET/PROJECT INFORMATION U Z <br /> s oe;.,^ OC a <br /> COMMON HALLWAYS,FREIGHT ELEVATOR VESTIBULES,ETC. FT -FIRE TREATED TBD -TO BE DETERMINED a CE <br /> FLIER -FURRING TEL -TELEPHONE QQ CL Q <br /> 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 31S -GOOD ONE SIDED TEMP -TEMPERED E ~ G F 2 <br /> ARCHITECTURAL/INTERIORS U <br /> 32S -GOOD TWO SIDED THK -THICKNESS LU Z LU <br /> X X A.0.1 SITE PLAN - LU a <br /> 17, UPON COMPLETION OF ALL CONSTRUCTION,THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH GA -GAUGE TO -TOP OF O M <br /> ONE SET OF"RECORD"AS-BUILT DRAWINGS. X X A.0.2 OCCUPANCY&EGRESS PLAN/SITE MODIFICATIONS O = Z m LU <br /> GC -GENERAL CONTRACTOR TOS -TOP OF SLAB DE w r> <br /> GL -GLASS TYP -TYPICAL Q- T LU <br /> 18, ALL MATERIALS TO BE NEW ION. GWB -GYPSUM WALL BOARD ION -UNLESS OTHERWISE NOTED <br /> GYP -GYPSUM UPS -UNINTERRUPTED POWER SUPPLY <br /> 19. PATCH ALL DISTURBED AND/OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS HC -HANDICAPPED VCT -VINYL COMPOSITION TILE <br /> REQUIRED FOR FINISHED APPEARANCE. HDW -HARDWARE VIF -VERIFY IN FIELD -F PROJECT ^^ <br /> HM -HOLLOUR W METAL(STEEL FRAME) W/ -WITH J l� III�� WSTATEO <br /> RED <br /> 20 FRAM NGGENERAL OR LIGHTTOXTURES,ER IS ONSIBLE LECTRICALOFIXTUURES,CASEWORK AND ALL OTHING ALL NECESSARY IER ITEMS REQUIRING NCLHE -NOLUDED OR INCLUDING WD -WOOD NG,BLOCKING,AND WC -WATER CLOSET LOCATION i,'ql„„it;I'��;I i''"("" CT <br /> IT. INFO -INFORMATION W/O -WITHOUT <br /> INSUL -INSULATION <br /> 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. LAV -LAVATORY VER <br /> LF -LINEAR FOOT NGTON <br /> 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE <br /> ARCHITECT'S REVIEW PRIOR TO INSTALLATION.SUBMIT TO ARCHITECT THREE(3)COPIES FOR REVIEW. <br /> 07/19/25 <br /> 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK,MILLWORK AND ANY <br /> OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION.SUBMIT TO ARCHITECT AT LEAST <br /> THREE(3)COPIES FOR REVIEW. DEFINITIONS AND DIMENSIONS KEY PLAN / FLOOR PLATE: 1/16" = 11-011 <br /> 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY NO. ISSUE/REVISIONS DATE <br /> PROVIDED AS IF DRAWN IN FULL. A. DEFINITIONSREVIEW SET 09.05.2023 <br /> 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE.THE LIST OFCONSTRUCTION WORK SHALL NOT PROCEED UNTIL THE PERMIT/CD SET 09.25.2023 <br /> ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST.THE ARCHITECT WILL DEFINE 1. "TYPICAL"OR'T'P"INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. BUILDING OWNER/REPRESENTATIVE HAVE GIVEN THEIR <br /> THE INTENT OF ANY IN QUESTION. APPROVAL TO THESE CONSTRUCTION DOCUMENTS. <br /> 2."SIMILAR"OR"SIM."INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE APPROVAL BY THESE PARTIES SHALL BE INTERPRETED AS <br /> CHARACTERISTICS FOR THE CONDITION NOTED. <br /> APPROVAL OF DRAWINGS FOR CONTENT,FINISH SELECTIONS, <br /> SCOPE OF WORK,AND ALL DIMENSIONS REGARDED BY EITHER <br /> 3."AS REQUIRED"INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE PARKAS BEING NECESSARY TO THEIR OPERATIONS,USE OF <br /> THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. THE SPACE,FURNISHINGS,AND TENANT EQUIPMENT AND <br /> FURNITURE INSTALLATIONS. <br /> 4. "ALIGN"INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT,TRUE,AND CONSTRUCTION AND/OR INITIATION OF CONSTRUCTION, <br /> SYMBOLS PLUMB RELATION ADJACENT MATERIALS. AUTHORIZED BY THE BUILDING OWNER FROM THESE <br /> CONSTRUCTION DOCUMENTS,SHALL BE INTERPRETED BY THE <br /> 5. "CLEAR"INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS. r DESIGNER AS APPROVAL IN FULL OF THESE CONSTRUCTION <br /> DOCUMENTS BY THE BUILDING OWNER/REPRESENTATIVE. <br /> ELEVATION REFERENCE SYMBOL INDICATES FINISHED B. DIMENSIONS: I °° <br /> U SURFACES TO ALIGN <br /> DETAIL ID 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING <br /> DRAWING TITLE BAR CONSTRUCTION,CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED. I COVER SHEET/ <br /> L X.X.X R �LE <br /> EEO <br /> SHEET NO. 2.ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT,TRUER PLUMB. I rAREA OF WORK PROJECT INFORMATION <br /> D DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. I I SUITE A <br /> a. STRUCTURAL DRAWINGS <br /> SECTION REFERENCE SYMBOL Ab. LARGE SCALE DETAILS c. SMALL SCALE DETAILS <br /> DTL d. ENLARGED PLANS AND SECTIONS <br /> SHT FLOOR ELEVATION SYMBOLS e. FLOOR PLANS <br /> NOMINAL FLOOR <br /> 3.MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS <br /> DETAIL REFERENCE SYMBOL ELEVATION HEIGHT PROJECT NO 23-037-00 <br /> (ABOVE/BELOW) SHALL BE MAINTAINED. I I <br /> DTL BUILDING SPACE/ROOM ID 4. FLOOR ELEVATIONS ARE INDICATED ATTHE FACE OF THE STRUCTURAL SLAB,UNLESS OTHERWISE I I DRAWN BY. RS G"O O <br /> SHT ROOM - SPACE NAME NOTED. -� REVIEWED BY:PG/HW <br /> COLUMN AND/OR GRID LINE SYMBOL 0 - SPACE NUMBER 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED r PERMITAGENCY <br /> DIMENSION LINE: DOOR SYMBOL&NUMBER MATERIAL,UNLESS NOTED ABOVE FINISH FLOOR-"AFF". <br /> 20' 0" 6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED <br /> DOOR NUMBER ACOUSTIC CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES,UNLESS <br /> OTHERWISE NOTED. <br /> 1 _ _ DOCUMENT SHEET SYMBOL <br /> 7. DOCUMENTS ARE DRAWN DIAGRAMATICALLY,AND SCALED DIMENSIONS ARE APPROXIMATE. <br /> OKEYED SHEET NOTE/TAGDIMENSIONS SHALL INDICATE REQUIRED SIZE,CLEARANCES,AND RELATIONSHIPS ARE INDICATED <br /> L ANGLE BY DIMENSIONS AS NOTED. <br /> @p AT G1 GLAZING SYMBOL/TAG <br /> CENTERLINE A - REVISION NUMBER/TAG <br /> Dngmel areW l 21x.Er.seele emulee ecoomlogry n,­ <br /> All IP-1.,&inlelleolual Property nQN,reservetl c 2023 <br />