My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1105 13TH ST 2024-06-07
>
Address Records
>
13TH ST
>
1105
>
1105 13TH ST 2024-06-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2024 7:14:07 AM
Creation date
5/29/2024 12:43:06 PM
Metadata
Fields
Template:
Address Document
Street Name
13TH ST
Street Number
1105
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS <br />ADJ Adjustable <br />AFF Above Finished Floor <br />AHJ Authority Having Jurisdiction <br />ANSI American National Standards Institute <br />AS Automatic Sprinklers <br />ASME American Society of Mechanical Engineers <br />ASR Automatic Sprinkler Riser <br />ASTM American Society for Testing and Materials <br />ATR All Thread Rod <br />AUX Auxiliary <br />AV Alarm Valve <br />AWS American Welding Society <br />BB Below Beam <br />BD Below Deck <br />BFP Backflow Preventor <br />BFV Butterfly Valve <br />BJ Below Joist <br />BL Branchline <br />BLDG Building <br />BOR Base Of Riser <br />BR Brass <br />CH Chrome <br />Cl Cast Iron <br />CL Centerline <br />COJ Out On Job <br />COL Column <br />CONC Concrete <br />COUP Coupling <br />CPVC Chlorinated Polyvinyl Chloride <br />CSP Combination Standpipe <br />CSR Coach Screw Rod <br />CTR Center <br />CV Check Valve <br />DCV Detector Check Valve <br />DI Ductile Iron <br />DIN Down <br />DSP Dry Standpipe <br />E Existing <br />EC Extended Coverage <br />ELEV Elevation <br />ELL Elbow Fitting <br />EQB Earthquake Brace <br />EXP Exposed <br />F Flanged <br />FDC Fire Department Connection <br />FH Fire Hydrant <br />FHC Fire Hose Cabinet <br />FHV Fire Hose Valve <br />FLR Floor <br />FM Factory Mutual Research <br />FOW Face Of Wall <br />FP Fire Protection <br />FS Flow Switch <br />Fr Foot <br />FTO Field To Order <br />G Grooved <br />GA Gauge <br />GALV Galvanized <br />GB Glass Bulb <br />GOE Groove One End <br />GOL Groove-O-Let <br />GPM Gallons Per Minute <br />GRC Grooved Reducing Coupling <br />GV Gate Valve <br />HDI HIM Drop -In Anchor <br />HSW Horizontal Sidewall <br />HT Height <br />HV Hose Valve <br />ID Inside Diameter <br />MECH Mechanical <br />MJ Mechanical Joint <br />MRA Most Remote Area <br />MT Mechanical Tee <br />NFPA National Fire Protection Association <br />NIC Not In Contract <br />NO Number <br />NPT National Pipe Thread <br />NTS Not To Scale <br />OC On Center <br />OD Outside Diameter <br />OH Ordinary Hazard <br />OS&Y Outside Screw & Yoke <br />P Plain End <br />PIV Post Indicator Valve <br />PL Property Line <br />POC Point Of Connection <br />PRV Pressure Regulating Valve <br />PS Pressure Switch <br />PSI Pounds Per Square Inch <br />PVC Polyvinyl Chloride <br />OR Quick Response <br />RES Residential <br />RN Riser Nipple <br />SBB Side Beam Bracket <br />SCH Schedule <br />SHT Sheet <br />SP Standpipe <br />SPK Sprinkler <br />SO Square <br />SR Standard Response <br />SSP Standard Spray Pendent <br />SSU Standard Spray Upright <br />SW Switch <br />T Thread <br />TEE Tee Fitting <br />TLW Threaded Lightwall <br />TOE Thread One End <br />TOR Top Of Riser <br />TW Thlnwall <br />TYP Typical <br />SYMBOL LEGEND <br />Existing Sprinkler On Line <br />Pendent Sprinkler on 1" Drop - New <br />N � <br />Z <br />IYz <br />Pipe Diameter (Inches) <br />_J <br />New Sprinkler Branchline - New <br />ZO Z <br />5-0 <br />— Pipe Length (feet -inches) <br />4 <br />z <br />LIA QQ <br />New Sprinkler Main -New <br />5-O <br />�Q <br />J <br />I <br />—) <br />— Sprinkler Piping - Existing <br />p <br />lit LL <br />NLU <br />0 <br />Change in Pipe Elevation <br />N <br />® System Riser <br />f Branchline Hanger Location <br />See Hanger Detail for Additional Info <br />12 Hydraulic Reference Point <br />Grooved Coupling <br />Grooved Cap <br />Threaded Cap <br />I� <br />SPRINKLER LEGEND <br />ADJUST SPRINKLER TEMPERATURES AS REQUIRED PER NFPA 13, 2016 PARAGRAPH 8.3.2 <br />SYMBOL MODEL S.I.N. K-FACT ORIFICE N.P.T. FINISH TEMP. TOTAL COMMENTS <br />® <br />EXISTING UPRIGHT SPRINKLER <br />5.6 <br />1/2" <br />1/2" <br />BRASS <br />2000 <br />- <br />e <br />VICTAULIC FL-QR PENDENT SPRINKLER <br />V2708 <br />5.6 <br />1/2" <br />1/2" <br />WHITE RECESSED <br />2000 <br />2 <br />SPRINKLER TOTALS: <br />2 <br />HANGER DETAILS <br />MAXIMUM DISTANCE BETWEEN HANGERS <br />NOMINAL PIPE <br />3/4" <br />1" <br />1-1/4" <br />1-1/2" <br />2" <br />2-1/2" <br />3" <br />4' <br />SIZE (in.) <br />STEEL PIPE EXCEPT <br />N/A <br />12-0 <br />12-0 <br />15-0 <br />15-0 <br />15-0 <br />15-0 <br />15-0 <br />THREADED LIGHTWALL <br />THREADED LIGHTWALL <br />N/A <br />12-0 <br />12-0 <br />12-0 <br />12-0 <br />12-0 <br />12-0 <br />12-0 <br />STEEL PIPE <br />CPVC PIPE <br />5-6 <br />6-0 <br />6-6 <br />7-0 <br />8-0 <br />9-0 <br />10-0 <br />N/A <br />� RE -LOCATE EXISTING MAIN DRAIN PIPING <br />RESTROOM <br />-6 <br />— —(2) — - <br />EXISTING UPRIGHT SPRINKLERS <br />HWT/STORAGI <br />TOLCO FIG. Gq"" <br />RETAINING <br />STRAP <br />/ TOP TRUSS <br />1 CHORD <br />12 <br />r�EXISTING MAIN <br />2 x IY4 MECHANICAL TEE <br />(E) DEGK, 20 GAUGE VERGO <br />1?" HB5-3b w/ 5HEARTRANZ <br />w/ 51DE LAP GONNEGTION. <br />BUTTON PUNGH ® 24' O.G. 4 <br />(7) HEL05 PER SHEET TO <br />5UPPORT5 <br />TENANT IMPROVEMENT PIPING PLAN <br />EXISTING LINE <br />HANGER ROD SIZES <br />NOMINAL PIPE <br />3/4" <br />1" <br />1-1/4" <br />1-1/2" <br />2" <br />2-1/2" <br />3" <br />4" <br />SIZE (in.) <br />STEEL PIPE EXCEPT <br />N/A <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />THREADED LIGHTWALL <br />THREADED LIGHTWALL <br />N/A <br />3/8- <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8- <br />STEEL PIPE <br />LOCK <br />,--'NUT REQ'D�_� <br />—]A <br />JA <br />VIEW A -A <br />TOLCO FIG. 65 <br />BEAM CLAMP <br />TOLCO FIG. 100 <br />ALL THREAD ROD <br />TOLCO FIG. 200 <br />ADJUSTABLE RING <br />HANGER <br />HANGER #2 (/' ) <br />TOP BEAM CLAMP, ROD, AND RING <br />13 <br />� F <br />(2)--�-- (2)`)— <br />I <br />a I <br />I <br />o <br />1 <br />D.6 <br />4" CONCRETE <br />SLAB -ON -GRADE. <br />SCALE: 1/4' . P-0' <br />GENERAL NOTES <br />1. The system design and installation shall comply with NFPA 13, 2022 <br />edition, and the Authority Having Jurisdiction. <br />2. Hazard classification: <br />Existing System was classified as Ordinary Hazard Group 1 and calculated at a <br />.15 gpm/sf over the most remote 1500 sf. <br />Tenant Improvement - Retail - Ordinary Hazard Group 1 <br />3. Provide spare sprinklers at existing head cabinet with wrenches. <br />4. All threaded piping to be Eddy -Thread black steel pipe. <br />5. Fittings shall be class 125 threaded cast iron ANSI 1316.4. <br />6. All threaded pipe and fittings shall have threads cut to ANSI/ASME standard <br />131.20.11. <br />7. All pipe welding shall be in compliance with the requirements of AWS 132.1 <br />(standard for building service piping). <br />8. All piping shall be earthquake braced as outlined in NFPA 13 2019. <br />9. Electrical wiring and any painting of the pipe that may be required shall be by <br />others. <br />10. All piping is to be hydrostatically tested at 200 psi minimum, for a period not less <br />than two hours. <br />11. Scope of Work: Provide 2 pendent sprinklers in 2 new rooms, piped from existing <br />system. <br />FLEXIBLE SPRINKLER DROP INFORMATION <br />MULTI -PORT BRACKET <br />KEY PLAN <br />FLEXHEAD SPRINKLER DROP <br />CORRUGATED STAINLESS STEEL <br />1405E WITH 5TAINLE55 STEEL <br />BRAID - SEE BELOW FOR MAX. <br />FLEXDROP LENGTH <br />ADJUSTABLE HUB <br />CEILING <br />PENDENT SPRINKLER <br />THE MAXIMUM FLEXHEAD LENGTH IS 36" <br />NOT TO SCALE <br />r — WASHINGTON STATE <br />CERTIFICATE OF COMPETENCY <br />FIRE PROTECTION SPRINKLER SYSTEMS <br />Eric A Price 11/08/23 <br />3437.0508-C Level Date <br />Southeast Fire Protection <br />SOUTHFPS78NR E�Ires <br />Erie. Pr" tz/s1/zs I <br />Signature <br />L— — — — — — — — — — — <br />a <br />z <br />LL <br />Q <br />LL <br />O <br />W <br />~ <br />O <br />00 <br />O <br />W 2;' <br />�o <br />7 <br />W <br />w <br />S <br />Q <br />J <br />LU <br />0 <br />z <br />JLU <br />= <br />W <br />2 <br />w <br />o <br />Z <br />U� <br />w� <br />O <br />0 D <br />U <br />zLU <br />a= <br />W <br />No <br />�J7 � <br />Q W <br />w¢ <br />Ly <br />o� <br />zo <br />O <br />V <br />N <br />Lf) <br />Ln <br />N <br />I <br />In <br />M <br />a <br />cc <br />ti <br />o0a <br />U <br />J <br />S <br />s <br />C <br />a <br />CD <br />° <br />V <br />UJ <br />rgQJ <br />U) <br />0 <br />0 <br />J <br />In <br />a <br />�O <br />WLU <br />y <br />W (� � <br />WaW <br />o �; <br />�z <br />W <br />a� <br />Q <br />z <br />a <br />REVISIONS <br />0 <br />0 <br />0 <br />SHEET TITLE <br />FIRE PROTECTION <br />DATE: NOVEMBER 08, 2023 <br />FILE: 33250 <br />OF I <br />
The URL can be used to link to this page
Your browser does not support the video tag.