Laserfiche WebLink
Permit#: K2402-002 <br /> Site Address: 1200 Industry St <br /> Applicant: Tang!Norris <br /> Application Date:02/16/2024 <br /> Description: Eldorado stone-Booth and Rack FITTER/LISTER NOTES <br /> Demo TI. <br /> Review Date: 02/21/2024 <br /> 1. SFS IS TO CAP THE SUPPLY LINES TO DEMO'D BOOTHS AND RACKS AT THE <br /> evsRErr <br /> EXISTING OUTLET AT THE ROOF. <br /> EVERETT <br /> Everett Fire Dept.Permit Review 2. DEMO AND DISPOSAL OF DISCONNECTED PIPING IS BY OTHERS. <br /> Status:Approved 3. EXCLUDING WORK ON OVERTIME OR AFTER HOURS. <br /> Reviewed By:KBrown 4. EXCLUDING RELOCATING OR MODIFYING THE EXISTING SPRINKLER <br /> 02/2112024 1:51:55 <br /> - $ PM SYSTEM TO ACCOMMODATE THE WORK OF OTHER TRADES. <br /> APPROVED <br /> - - - • o-. , r. , - m n a• m n a• d PUBLIC WORKS DEPARTMENT <br /> BY:THerman GENERAL NOTES <br /> DATE:02/26/2024 <br /> T I CITY OF EVERETT REVIEWED FOR PERMIT <br /> 1. ALL STEEL PIPE TO BE AS FOLLOWS UNLESS NOTED OTHERWISE: <br /> ---- ---- I I I STEEL PIPE ASTM A-795 OR BETTER <br /> F L I F I PIPE WALL INTERNAL wregiaE GALLONIGW OF <br /> SCHEDULE END PREP TYPES ALLOWED a <br /> SIZE THICKNESS DIAMETER wA 1 s <br /> 2"CAP TO 1 2"CAP TO <br /> CAP TO l 1 40 0.133 1.049 THREADED,CUT GROOVED,ROLL GROOVED,PLAIN END,POLISHED 2.05 0.044 <br /> DISCONNECT DUAL DISCONNECT DUAL DISCONNECT DUAL 2 FLOW PIPE 0.095 2.185 ROLL GROOVED,POLISHED,PLAIN END(FOR BUR WELDING) 3.94 0.198 <br /> BOOTH SUPPLY BOOTH SUPPLYI 1 BOOTH SUPPLY <br /> -� -� � -D� -� -0� -� A -� � � �� . D~ - 0-T - - �=1 ��I10� 1-, --ji 0� �- - IF 40 H E <br /> ❑ ❑ ❑ ❑ ❑ ❑L-- -J LL ----- I L- ---J❑ ❑ ❑ r - WALL THICKNESS PER NFPA#13 <br /> -9 <br /> m w-- ---R 2. ALL GROOVED COUPLINGS TO BE RIGID TYPE UNLESS NOTED(III)WHICH ARE FLEXIBLE. <br /> 0- --4 Ar-- or--- --0 -H�- <br /> 1 SCOPE OF WORK <br /> ___J <br /> DISCONNE T <br /> m-t I <br /> �ACK�tI <br /> 01 a a a m 4 <br /> L <br /> --J-----L- L JJ___JJ___JJ___J SMITH FIRE SYSTEMS(SFS)WILL MODIFY THE EXISTING SPRINKLER SYSTEM TO REMOVE <br /> SPRINKLER PROTECTION FROM RACKS AND BOOTH SCHEDULED FOR DEMO.SFS WILL CAP <br /> I L------ L------ I THE SUPPLY PIPING TO(7)INRACK SPRINKLER LINES,AND(10)SPRAY/SANDING BOOTHS. <br /> RA z„�q�JpTY�t 111 11 11 J_-_J <br /> u11 <br /> JL___JL___JL_-_ L-___JL___JJ___JJ___J <br /> - SUPPLY -- CLARIFICATIONS: <br /> II 1 <br /> 1. ALL AREAS PROTECTED BY A WET PIPE SYSTEM MUST BE MAINTAINED AT 40°F IN <br /> ORDER TO PREVENT FREEZING. <br /> �� r r 2. SPRINKLER MODIFICATIONS ARE BASED UPON HAVING ADEQUATE PRESSURE <br /> � � +� xg� W� --4 � � � 1.. 0 $ $ Or � $ $ $ 3� $ B 0 0 D <br /> JL JL JL JL J �cLL AVAILABLE AT THE POINT OF CONNECTION <br /> ISCONNL r - -�r -�r -�r - 3. MATERIALS INSTALLATION AND DESIGN PER NFPA 13 STANDARDS AS SELECTED BY <br /> � <br /> II C __ __ _ _ <br /> �_K SUPP�tL �I �� �� � SFS. <br /> u II 1 <br /> 4. DISCONNECTING(7)INDIVIDUAL SPRINKLER DROPS THAT FEED IN RACK SYSTEMS. <br /> ---�r---��---��---�r---�r---�r---�r---��---��---��---��---� <br /> THE 4"SUPPLY MAIN AT THE ROOF WILL REMAIN. <br /> 5. PIPING FEEDING PAINTBOOTHS AND INRACK SPRINKLERS WILL BE CAPPED AT AN <br /> � � I I � EXISTING OUTLET. <br /> 2"CAP � �r �r �r � 2'CAPTO <br /> - _z"CAP ro - DISCONNECT 6. EXISTING UPRIGHT SPRINKLERS AT THE ROOF WILL NOT BE REMOVED OR MODIFIED. <br /> ISCONNE'T�C <br /> -_ ___J _ L-___JL___JL____JL____JL____J BOOTH SUPPLY <br /> � � L J � � � �� � � � � ---s- $ � � $ R� � W <br /> RACK <br /> 'DISCONNECT �___ ~0 $ 0 <br /> -- - - -- ,� -,��, 1 I EXCLUSIONS: <br /> ❑ L '1 JJ___JJ___JJ___J 0 ❑ ❑ ❑ ] <br /> �r �r � r � ❑ ❑ ❑ � ❑ 1. REMOVAL OF DEMO'D MATERIAL OR TRANSPORTING TO A DUMPSTER. <br /> �-- - �' J • 2. ANY ADDITIONAL DEMO OTHER THAN DISCONNECTING AUXILIARY SYSTEMS. <br /> ��� �r _____ R 3. FLOOR MUST BE FREE AND CLEAR OF MERCHANDISE,STOCK,RACKING OR <br /> _ <br /> ---� - - <br /> 1 I L � CONSTRUCTION MATERIALS TO ALLOW FOR ACCESS TO PIPE AT THE STRUCTURE. <br /> DISCONNECT X11 JL J - z"CAP ro 4. CUTTING PATCHING OR FIRE CAULKING OF WALLS,CEILINGS,OR FLOORS <br /> - 11 BKPpty 5. ACCESS PANELS OF ANY KIND. <br /> -nF- 0 � �[_ - ISCONNECT -W 0 0 0 <br /> T I II I � <br /> T. <br /> sur Lv I BoorH suPPLv�� --_�1 1 6. DOH,FM,INSURANCE,OR OTHER OUTSIDE REVIEW REQUIREMENTS,APPROVALS OR <br /> -- L-- J J- Jr--` 1 2..CAP TO-- L---Jr-- ter-- -ter- --�J--- - -J DlscoNNFCr�T --- FEES <br /> L- - JIL _DISCONNECT L---JL-�JL- JL JL --J fj LLL $ 7. HEAT TRACE OR INSULATION A ANY KIND <br /> 2"CAP SUPPLY b # 8. ANY WORK OUTSIDE THIS TENANT SPACE OR IN EXISTING OFFICE AREAS. <br /> ---- --JL---J �A f 9. PAINTING OR LABELING OF PIPE. <br /> r �r CK su m 2"CAP S m m #1 10. REPLACEMENT OF PAINTED,DAMAGED,OR CORRODED SPRINKLERS. <br /> 10 I1 IIS Q� I� 1- +I-B8 a-- � �� � ��� �B8 � � �8 -4 � r0 � $ 3� �fl $ d� a1 B� �� $ 9� �U $ B� $ 10 <br /> _J ___JL-___-L___JJ___JJ___JJ___JJ___J 11. ELECTRICAL OR ALARM WORK OF ANY KIND. <br /> 12. BACKFLOW INSTALLATION,MODIFICATION,OR CERTIFICATION(IF REQUIRED) <br /> 13. REPAIRS OR MODIFICATIONS TO THE EXISTING SYSTEM BEYOND THE SCOPE <br /> _ DESCRIBED ABOVE. <br /> EXISTING RISER 14. FIRE WATCH OR TEMPORARY SPRINKLER PROTECTION DURING CONSTRUCTION. <br /> LOCATION 15. MODIFICATIONS REQUIRED TO ACCOMMODATE THE WORK OF OTHER TRADES <br /> 16. STRUCTURAL ANALYSIS,SEISMIC INVESTIGATION,OR PE REVIEW UNO <br /> 17. UNDERGROUND WORK OF ANY KIND <br /> DEMO SPRINKLER PLAN <br /> z 0 16 32 DESIGN CRITERIA: <br /> SCALE 1/16"=1'-0" PER NFPA 13 2013 AND THE CITY OF EVERETT <br /> EXISTING CRITERIA(UNCHANGED): <br /> OVERHEAD PROTECTION <br /> STORAGE-.385/OVER 2000 SO.FT. <br /> TENANT IMPROVEMENT: <br /> THIS PROJECT IS A TENANT IMPROVEMENT. THIS FACILITY HAS ALREADY BEEN PROTECTED <br /> BY A FIRE SPRINKLER SYSTEM. SMITH FIRE SYSTEMS IS ADDING AND/OR RELOCATING <br /> SPRINKLER HEADS TO ACCOMMODATE THE NEW TENANT WALL,CEILING,LIGHTING,AND <br /> HVAC LAYOUT. ALL WORK WILL BE DONE WITHOUT AFFECTING THE CAPABILITY OF THE <br /> EXISTING SYSTEM;THEREFORE,NO NEW HYDRAULIC CALCULATIONS ARE NECESSARY. <br /> r WOOD ROOF DECK <br /> EX BRANCHLINE 11 <br /> IXSSP - - - - - - - • <br /> STEEL BARJOIST <br /> SM <br /> Everett 2 <br /> EXISTING RISER <br /> LOCATION <br /> ® PORT GARDNER <br /> 535 <br /> BOOTH DEMO ® Forest ark <br /> AREAS OF WORK�® , <br /> ®® ® LO ell Park <br /> Lighthouse. <br /> F/a TSI( DARLINOTCN FO FORESTSOUPA <br /> ®® ® �� <br /> VIEW RIDGE GLACIER VIE <br /> MADISON <br /> ®® BOULEVA flD OWECL�'� <br /> •Mu itteo BLUFFS <br /> RACK DEMO <br /> AREAS OF WORK PINEHURST-BEVERLY <br /> PARK <br /> I <br /> LEY VIER' <br /> eoell'1A'Future o Flight <br /> I WESTMONT <br /> Paine Field CASCADE VIEW <br /> N N <br /> BUILDING SECTION SITE PLAN AREA MAP <br /> NTS NTS NTS <br /> DEMO PLAN <br /> ABBREVIATIONS SYMBOL LEGEND SYMBOL LEGEND PIPE LEGEND FLEX LEGEND SPRINKLER LEGEND REVISIONS CONTRACT WITH SMITH FIRE SYSTEMS, INC. <br /> AFF ABOVE FINISHED FLOOR A NEW 1"PLUG MAKE TYPE LEN NIPPLE BRKT SCRW QNTY SVM MANUFACTURER S.I.N. TYPE MODEL F'FlrwilsnR escFxcNcax aeRce TMaG I-- <br /> AFF NO. DATE BY REASON FOR REVISION ��� <br /> BOB BOTTOM NI BFAM 12 CENTERLINE OF PIPE TO REFERENCED NEW SPRINKLER PIPE 1SX ELDORADO STONE 1106 54th AVE EAST <br /> BOD BOTTOM OF DECK STRUCTURE IN INCHES EXISTING # -/-/-- <br /> BOJ BOTTOM OF JOIST BOD EXISTING SPRINKLER PIPE UNCHANGED SSP CHR CHR 5.6K 1/2" ,55° -- 1200 INDUSTRY ST _____ _ ____ TACOMA,WA 98424 <br /> BOP BonoM of PuauN TH �S3 oTE 7 CONTR.REG.NO.SMITHFS1360T <br /> BOR BOTTOM OF TRUSS 2-WAY EARTHQUAKE SWAY BRACE NEW 1/2"PLUG - - RELOCATED EXISTING PIPE �. UNCHANGED SSU BRZ --- 5.6K 1/2" ,55° -- BUILDING INFORMATION EVERETT,WA F1Rs PRo Ecilon°svRlrvlMCLsn sysisrns <br /> crs cur ro sun LETTER INDICATES TYPE _ NEW FLEXDROP �k UNCHANGED SSP BRZ 16.8K 3/4 286° - Bassione Sean Van Soes[ Bus:(253)926-1860 FAX:(253)926-2350 <br /> FO FIELD ORDER MAINTENANCE CONTACT <br /> IPOW INSIDE FACE OF WALL + 4-WAY EARTHQUAKE SWAY BRACE S NEW STRAP OUTLET �� �� RELOCATED EXISTING FLEX <br /> � 6027-0110-C Level3 � <br /> OF o OUTSIDE FACE OF- LETTER INDICATES TYPE MAINTENANCE PHONE: 1 Smith Fire Systems,lnc. ELDORADO STO N E <br /> NAS NO AUTO.SPRINKLERS PROJECT MANAGER: IAN HACKER 1 SMITHFS1360T "=� <br /> UNO UNLESS NOTED OTHERWISE f HANGER LOCATION MT NEW MECHANICAL TEE OUTLET BRACKET LEGEND: NEW ALARM COMPANY: 8.1 <br /> N.I.C. NOT IN CONTRACT WALLALARM PHONE <br /> LEGEND ACT=STANDARDOGSBBRACKET OFFICE PHONE: EaPir.: <br /> GWB T-BAR,TBS ENDS,AND OSSB CLAMP �� <br /> TOE THREAOONEEND ELEVATION ABOVE REFERENCED = CELL PHONE: 951-412-7864 BOOTH AND RACK DEMO TI <br /> SIDE GROOVEONE END � POINT INFEET AND INCHES R RELOCATED EXISTING SPRINKLER EXISTING WALL ALARM CODE: � ����������3 1200INDUSTRY ST <br /> TEE THREAD BOTH ENDS NEW WALL TO CEILING HYDRAULIC CALCULATION NODE p EXISTING THREADED OUTLET HCB=T-BAR,HCB ENDS,AND OSSB CLAMP ALARM PASSWORD: EMAIL: IHACKER@WESTLAKE.COM EVERETT,WA <br /> 4'BAR=T-BAR,TBS ENDS,AND OSSB CLAMP <br /> OSUPERINTENDENT: <br /> NEW FULL HEIGHT WALL TEK=(2)1/4"x1.5"TEK SCREW FIRE DEPARTMENT: <br /> FLEXIBLE COUPLING = <br /> (E) EXISTING SYSTEM COMPONENT WDS 2 NEW LOW WALL ()#1 0x1.5"WOOD SCREW FIRE DEPT.PHONE*. PHONE <br /> EMAIL: DESIGNER PROJECT MGR DATE SHEET JOB NO. <br /> RIGID COUPLING I NEW SOFFIT WALL so xv2"=90'NIPPLE 6"LONG CERTIFICATE OF COMPETENCY STAMP JOHN R LANE L. 1 02-16-24 1 1 OF 1 N124001 <br /> 9"x1/2"=9"LONG x 1/2"EXTENDED NIPPLE TOTAL NEW # <br />