My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE BASE FILE 2024-06-06
>
Address Records
>
PACIFIC AVE
>
916
>
BASE FILE
>
916 PACIFIC AVE BASE FILE 2024-06-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2024 1:08:32 PM
Creation date
5/29/2024 12:53:40 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: K2403-001 <br /> Site Address: 916 Pacific Ave <br /> Applicant: Dion Smith <br /> RPM(\ SYMBOLS: <br /> V ^D OI C• Application Date:03/04/2024 <br /> 1 TO SCOPE OR WORK BY BURNS FIRE PROTECTION SYSTEMS,INC. V V J RVI J LJ Description: 31051add(6)heads <br /> ELEVATOR Review Date: 0310512024 03/05/2024 <br /> ROOM IS TO EXTEND SPRINKLER PROTECTION TO ELEVATOR PENTHOUSE AT ROOF. fr Approximate Hanger Location <br /> PIPING GENERAL NOTES: +J Approximate Bracing Location <br /> 1. DESIGN AND INSTALLATION TO CONFORM WITH CITY OF EVERETT AND NFPA#13, 2019 <br /> *F ELEVATOR ROOM PENTHOUSE 2. ALL MATERIALS TO BE NEW AND UL OR FM LISTED. -8- Approximate Location of Grooved Coupling <br /> 3. PROTECTION OF SPRINKLER FROM PAINT BY OTHERS. +0-0 Elevation from Floor to Centerline of Pi e <br /> 5. STEEL PIPE JOINED'MTH THREADED FITTINGS TO BE BLACK SCHEDULE 40 p EVERETT <br /> <0 5. STEEL PIPE JOINED WITH GROOVED COUPLINGS TO BE BLACK EDDYFLOW WITH WELDED OUTLETS -0 BOJ Elevation down from Joist to Centerline of Pipe <br /> *F 6. SYSTEM HYDRAULIC DESIGN BASED ON ORDINARY HAZARD GROUP 1 P Everett Fire Dept.Permit Review <br /> FROM <br /> Status:Approved <br /> ELEV. 5 FROM 7 ALL SWAY BRACING TO BE 1"SCH40 PIPE FASTENED PER APPROPRIATE DETAIL. -0 BOB Elevation down from Beam t0 Centerline of Pipe <br /> EXISTING 8. ALL GROOVED COUPLING ARE TO BE RIGID UNLESS NOTED OTHERWISE. Reviewed By:KBrown <br /> AIN 9.FLOW AND TAMPER SWITCHES TO BE PROVIDED AND INSTALLED BY BURNS FIRE (0'-0") Center to Center Dimension of Pipe 03/05/2024 1:25:49 <br /> O 10.ALL ELECTRICAL WIRING TO BE PERFORMED BY OTHERS. PM <br /> <p 6 11. ALL FLOW SWITCHES AND TAMPER SWITCHES SHALL BE TAMPERED/MONITORED AS 0'-0" Cut Dimension of Pipe <br /> REQUIRED BY CODE. APPROVED <br /> 10 UNION WALL MOUNT CABINET BY OTHERS <br /> 12. IT IS THE RESPONSIBILITY OF THE OWNER TO PROVIDE ADEQUATE HEAT O Hydraulic Reference Point PUBLIC WORKS DEPARTMENT <br /> o\o TO PREVENT FREEZING WATER IN THE PIPES FOR WET SYSTEMS. 0 0 Rise/Drop BY:THerman <br /> r C " O 13. ALL PENETRATIONS THRU RATED CONSTRUCTION WALL SHALL BE FIRECAULKED. DA TE:03/22/2024 <br /> 22'-6 1/4 14. NUMBER OF SPRINKLERS IN THIS SUBMITTAL 6 ® Main Sprinkler Riser CITY OF EVERETT REVIEWED FOR PERMIT <br /> ELEV. 4 <br /> UNION c0 (NAS) No Automatic Sprinklers <br /> O O (NTS) NOT TO SCALE maximum. <br /> Calculation results for Design Area 1 -ELEVATOR PENTHOUSE s acing <br /> we ht ft maximum ) <br /> This system as shown on BURNS FIRE PROTECTION SYSTEMS,Watpany print no dated 3/3/2024 9 ( pounds <br /> 1- water fi led hanger <br /> for PROVIDENCE PACIFIC CAMPUS at ELEVATOR PENTHOUSE SIZE PIPE TYPE/SCHED. NOM. ID pipe pecing 5xWEIGHT+250 <br /> contract no is designed to discharge at a rate of 0.15 gpmKF(UmiNm°)of floor area over INCHES INCHES ounds feet) <br /> a maximum area of 651 W when supplied with water at a rate of 113.3 qpm at 41.2 psi at the base of the riser. <br /> 1" SCH 401.049 2.05 12'0" <br /> Hose stream allowance of is included in the above. 1"1/4" SCH 10 1.492 2.52 12'0 401 401.2 <br /> 5-1EtEV. 3 Occupancy classification:CHI Number of heads flowing:s <br /> ELEVATOR ROOM CONTROL VALVE Commodity classification: System Type: Wet 1 1/2" EDDY FLOW 1.728 2.71 12'0" 412.6 <br /> FLOW SWITCH AND VALVE Maximum storage height: Maximum velocity: 15.5 fl/s <br /> ao <br /> SUPERVISION BY OTHERS Storage arrangement: 2" EDDY FLOW 2.203 3.79 15'0" 534.25 <br /> WIRE PER STATE ELEVATOR CODE O Flow from In-Rack sprinklers: Ogpm Pressure Required at Source: 41.2 psi 3 1/2 0 <br /> EDDY FLOW 3.314 7.18 12' 680.8 <br /> Flow from Overhead sprinklers: 113.3 gpm Pressure Available at Source: 63.8 psi 4 <br /> EDDY FLOW 4.31 10.86 8' 684.4 <br /> O Flow from Inside Hoses: 0 gpm Surplus Pressure at Source: 22.6 psi <br /> �7 Flow from Outside Hoses: 0 gpm <br /> 38 1OZ 1O Other fixed flows: Ocom NOTE: LOAD RATING USED 760#BASED ON MANUFACTURERS PUBLISHED DATA IN ESR REPORT <br /> Total flow in syonal flow stem piping: 113.3 gpm PER NFPA#13 5x WEIGHT OF WATER FILLED PIPE+#250 REQUIRED <br /> AdditDesign Area 1 Wet System Totalofa0 flows: <br /> source: 113.3 Qpm <br /> 9 Y 7TH FLOOR 9P <br /> 5-1 z ' <br /> ELEVATOR PENTHOUSE <br /> Demand Calculations using Hazen-Williams Method <br /> Occupancy Classification: OH1 -u <br /> �;:r^a6° <br /> ELEVATOR CONTROL ASSY. g �rn«m ,,;�,Eg ^aa°," WALL <br /> Design Area Density: 0.15 1 <br /> o 7TH FLOOR 1/2"=1'0" ° ° >5 u• <br /> Additional Outside Hose: 0 1 <br /> 01 103 106 Design Area Size: o "' JJ <br /> S/8" uNISTRUT <br /> ELEV. 211 -Ni <br /> �' Notes: ° °".TM°°_ 2N"r"=o°��r°°... <br /> iir <br /> 5-112 04 � ��c :`N, ywrN•orwrsrwl"•sw <br /> n N <br /> I - � <br /> s B 2 <br /> N'n + Ln '° IO aoO Kwss rr•rw I1R� <br /> 117 a 11a44 2,0, SUPPLY FROM LEVEL 7 NW1pp�r� ter.. <br /> 19-1012 19-1012 17 •T60VNON TYPICAL HANGER FOR VALVE ASSEMBLY <br /> 2360 <br /> 1-5 o °k�sao <br /> E <br /> /41 HANGER TO CONCRETE FLOOR OEC(1•TO 4 PIPE <br /> N.T.S. <br /> Source Inforaisdon 5 00 356.00 <br /> Date of Flow at llMo:2023 4 OD 716.00 <br /> Location Mfl test data: 2 00 1166.00 .. .• <br /> PUMP SUCTION '4'• .�A y <br /> Sour dflowtestdata: v-' • <br /> • ; <br /> 12'9"� Sou.Data oints P a! weF F, AFCON FIG 077Pessu1/2" <br /> .w 1 <br /> /2" X3I1 <br /> 4 EMBED CONC. ANCHOR <br /> 4.9 <br /> 64.00 0.)0 BRACE ATTACHMENT <br /> °° HILTI KB- <br /> /� 50.00 1168.00 W/COUPLING � G'STRGCTLI� <br /> WATERS PPLY INFORMATION Oma' • �_• _• <br /> USED FO CALCULATIONS BASED b <br /> ON PUMP TESTS CONDUCTED IN MY 2p23 AFCON FIG 077 • • J •°• � • � +4 <br /> CROSSMAIN 1/2" 3 1/4" EMBED CONC. ANCHOR <br /> KB-TZ <br /> W/ PUNGCOUPLING <br /> s AFCON MEL E <br /> CROSSMAIN BRACE ATTACHMENT + e AFCON FIG 077 <br /> ❑ PIPE CLAMP <br /> PUMP ROOM USED IN LONGITUDINAL BRACE <br /> X LOWER LEVEL o z y, s• 1/8"=1'-0" N LONGITUDINAL SWAY BRACE LATERAL ( TRANSVERSE) BRACE <br /> �V 17S UPPITY FROM LEVEL 2 <br /> I><*Gcite A2360 <br /> EXISITNG OS&Y CONTROL VALVE <br /> 14 <br /> ° CONNECTION TO EXISTING 4" CROSSMAIN <br /> 11 5-2 4 <br /> 10 <br /> L17 <br /> FP1 �l <br /> P <br /> �1 2 0 <br /> 1-012 <br /> UP TO ROOF d <br /> LEVEL ELEVATOR <br /> ROOM <br /> O <br /> m <br /> O FIRE PROTECTION PLAN N T IF 1 1 7 <br /> g ®® <br /> 7TH FLOOR o• 1• z a• 1/4"=1r IT <br /> '-0" <br /> N ❑ <br /> EED MAIN DOWN TO PUMP L ° <br /> LOWER LEVI <br /> SUPPLY ROUTING <br /> �Xf LEVEL 2 w z, ,. 6 „8••-,,_„ NE12: KEY PLAN N ° T° S ° AREA OF WORK <br /> ED MAIN LEV L 2 ISER TO LEVEL 7 ROOF/LEVEL 7 <br /> I <br /> NOTES REVISIONS SPRINKLER SYMBOLS PIPING PLAN <br /> DATE DESCRIPTION BY 7��v <br /> ROOF PENTHOUSE <br /> ••,-..-------'""".......--. 3/5/2 RELOCATE LINE WITH SIDEWALL HEADS TO AVOID sYM cNT POBInoN FINISH TEMP K NPT SIN MEG. MODEL BFPS, INC Providence Pacific Campus <br /> Esplm WASHINGTON STATE MOVEABLE SUPPORT BEAMS Q 3 uPR BRASS 200 5.60 I/2" Vx300 VIKING vK300 PERMIT NO. <br /> • CERTIfICATE Of COMPETENCY; <br /> m�oc) <br /> „'� FIRE SPRINKLER SYSTEMS <br /> 'z d 3 SIDE BRASS 200 5.60 12" Vx305 VIKING vK305 CONTRACT NO. <br /> / P.O.B. 1110 <br /> 1%/ Da�vidY Yates x,813 916 Pacific Ave <br /> Bums Fire Protection Systems,Inc. GRANITE FALLS, WA Everett, WA APPROVAL clrY of EVERETT <br /> m NSF 84 D YYYv DCAWE By 1/8 D.1ATEoS <br /> 425-388-0124 <br /> :SlSneture Oste : DATE 3/3/2024 <br /> --•-•••-•-•• - ~• DESIGN QUESTIONS 360-580-1062 <br /> CONTRACTOR: City of Everett R LASED FP 1 <br /> PLOTTED <br />
The URL can be used to link to this page
Your browser does not support the video tag.