Laserfiche WebLink
1-STUDS: 3-EXTERIOR FACE: <br /> 2x6 WOOD STUDS @ 16"Q.C.ON 2x6 DOUBLE %''TYPE X GYPSUM WALLBOARD 4'WIDE <br /> TOP PLATE.SINGLE 2x6 BOTTOM PLATE. APPLIED HORIZONTALLY OR VERTICALLY. <br /> VERTICAL JOINTS TO BE OVER STUDS.FASTENED <br /> 2 INTERIOR FACE:' WITH 2X"TYPES DRYWALL SCREWS SPACED 7" <br /> (UNLESS SPECIFIED OTHERWISE BY ENGINEER) <br /> K"TYPE X GYPSUM WALLBOARD 4'WIDE <br /> APPLIED HORIZONTALLY OR VERTICALLY. 4-INSULATION: <br /> VERTICALJOINTSTO BE OVER STUDS.FASTENED S}W"INSULATION WITH R-VALUE PER ENERGY NOTES& <br /> i. WITH 2X"TYPES DRYWALL SCREWS SPACED 7" CALLOUTS.NOT REQUIRED FOR FIRE RATING <br /> O.C. <br /> 5-SIDING: <br /> AN'Y APPROVED EXTERIOR SIDING INSTALLED <br /> OVER APPROVED WATERPROOF BARRIER <br /> NOTE:RATING ESTABLISHED FROM <br /> BOTH SIDES PER IBC765.5 <br /> 0 0 <br /> irS9PS" ""1.11 I I fir <br /> • <br /> I 0 <br /> A-E EXTERIOR WALL ASSEMBLY <br /> FIRE-RESISTANCE DISTANCE - LESS THAN 10' <br /> TABLE 721.1(2)RATED FIRE-RESISTANCE <br /> PERIODS FOR VARIOUS WALLS& <br /> PARTITIONS <br /> I ITEM#15-1.14 MINIMUM THICKNESS <br /> FACE TO FACE W`"=1HOUR <br /> FOOTNOTE'L'-WOOD STRUCTURAL PANELS SHALL BE PERMITTED <br /> TO BE INSTALLED BETWEEN THE FIRE PROTECTION AND THE <br /> WOOD STUDS ON EITHER THE INTERIOR OR EXTER4OR SIDE OF THE <br /> WOOD FRAME ASSEM BLIES IN THIS TABLE,PROVIDED THE LENGTH <br /> OF THE FASTENERS USED TO ATTACH THE FIRE PROTECTION IS <br /> INCREASED BY AN AMOUNT NOT LESS THAN THE THICKNESS OF <br /> THE WOOD STRUCTURAL PANEL, <br /> FrF uuovtA <br />