My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5101 BEAUMONT DR 2024-07-02
>
Address Records
>
BEAUMONT DR
>
5101
>
5101 BEAUMONT DR 2024-07-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2024 1:31:25 PM
Creation date
6/4/2024 1:22:00 PM
Metadata
Fields
Template:
Address Document
Street Name
BEAUMONT DR
Street Number
5101
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R330.8.3A Fixed position grab bars. Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from <br /> the rear wall. <br /> R330.8.3.2 Swing-up grab bars, Swing-up grab bars shall be a minimum of 28 inches in length from the rear wall. <br /> R330.8.4 Grab bars at bathtubs. Horizontal and vertical grab bars shall meet the requirements of R330.8. <br /> R330.8.4A Vertical grab bars.Vertical grab bars shall be a minimum of 18 inches long and installed at the control end wall and <br /> head end wall.Grab bars shall mount within 4 inches of the exterior of the bath tub edge or within 4 inches within the bath tub_The <br /> bottom end of the bar shall start between 36 inches and 42 inches above floor grade <br /> EXCEPTION: The required vertical grab bar can be substituted with a floor to ceiling grab bar meeting tate <br /> requirements of R330.8 at the control end and head end entry points. <br /> 8330.8.4.2 Horizontal grab bars.Horizontal grab bars shall be provided at the control end,head end,and the back wall within the <br /> bathtub area.Grab bars shall be mounted between 33 inches and 36 inches above floor grade_Control end and head end grab bars <br /> shall be 24 inches minimum in length. Sack wall grab bar shall be 36 inches minimum in length. <br /> R330.8.5 Grab bars at shower stalls.%Ahiere shower stalls are provided to meet the requirements for bathing facilities,grab bars <br /> shall meet the requirements of R330.8. <br /> EXCEPTION: Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab <br /> bars at the seat end wall.A vertical floor to calling grab bar shall be installed within 4 inches of <br /> the exterior of the shower aligned with the nose of the built-in seat. <br /> R330.8.5.1 Vertical grab bars.Vertical grab bars shall be 18 inches minimum in length and installed at the control end wall and <br /> head end wall_Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower <br /> stall.The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade: <br /> R330.8.5.2 Horizontal grab bars. Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 <br /> inches and 36 inches above the floor grade.Horizontal grab bars shall be a maximum of 6 inches from adjacent walls. Horizontal <br /> grab bars shall not interfere with shower control valves. <br /> R330.9 Ramps.All interior and exterior ramps,when provided,shall be constructed in accordance with Section R311.8 with a <br /> maximum slope of 1 vertical to 12 hodzontai The exception to R311.8.1 is not allowed for adult family homes. Handrails shall be <br /> installed in accordance with 8330.9.1. <br /> R330.9.1 Handrails for ramps. Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal <br /> and 1 vertical and 20 horizontal in accordance with R311.8.3.1 through R311.8.3.3. <br /> R330.10 Stair treads and risers.Stair treads and risers shall be constructed in accordance with R311.7.5.Handrails shall be <br /> installed in accordance with R330.10.1. <br /> R330.10.1 Handrails for treads and risers.Handrails shall be installed on both sides of treads and risers numbering from one riser <br /> to multiple risers. Handrails shall be installed in accordance with R311.7.8.1 through R311.7.8.4 <br /> R330.11 Shower stalls.Where provided to meet the requirements for bathing facilities,the minimum size of shower stalls for an <br /> adult family borne shall be 30 inches deep by 48 inches long. <br /> (Statutory Authority RCW ,2i C3 t and chapters 18_27 and 34 05 RCW 13-04-068,§51-51-0325,filled 211!13.effective 71l/13.Statutory <br /> Authority:Chapter 119_27 RW.C1018.036.§51-51-0325,fled 8!25{10,effective 9125110.Statutory Authority:RCW 1 v-z7 ; c, 14 27 020.and <br /> chapters 119 2727 and 34.05 RUIN a9-04.023.§61-51-0325,filed 1/271'09,effective 711110 Statutory Authority.RCW 1;.27.074. 19 27.020.and <br /> chapters 119 2?and 3445 RCIN.07.01.090,§51-51.0325,filed 12119106,effective 71107.Statutory Authority:RCW 19 27 Q31,and c,3 27071.04- <br /> 01.109.§51.51.0325,filed 12/17/03 effective 7r1,04.)lStalutory Authority:RCW 19,27.031 and 19.27.074 WSR 20-03-023.§51-51-0330.filed <br /> 176120,effecEve 711120) <br /> implernentation Date:2021 February 01 <br /> Updated:2021 February <br />
The URL can be used to link to this page
Your browser does not support the video tag.