Laserfiche WebLink
: . . _ . . — <br /> { GENERAL YES NO <br /> F Bathroom doors are easily and quickly openable from the outside when locked 0, <br /> Carbon Monoxide alarms are installed as required in R315 on each level of the home. I ❑ <br /> i Smoke alarms are installed on all levels of the dwelling,in each resident sleeping room,outside each separate91 13 <br /> I <br /> sleeping area In the immediate vicinity of sleeping rooms(11314). <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all ❑ f <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requirements. 4 13 <br /> 8330.4 O erable , :`. —...:.... _ <br /> p parts of door handles,pails,latches,locks and other devices installed in AN shall be operable T <br /> with one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). 12 ❑ <br /> Pocket doors shall have graspable hardware available when in the closed or open position. JBC1 }} <br /> ft312,t3.fam <br /> ­77777777 <br /> fnsfde Rartnp 13 0 <br /> R311.8.1 Maximum Slope cine unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8-1 Nat alloyed in). ❑ 13 <br /> I R330.9) <br /> j R311.8.2 landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where <br /> ramp changes directions. 13 ©� <br /> --- <br /> • 8330.9.1 Handrails required on both sides of ramp. <br /> : . <br /> YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Nat allowed inj ❑ <br /> ' R330.9) <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where 13Tramp changes directions. _..............._ <br /> R330.9.1 Handrails required on both sides of ramp. <br /> R312.1.1 Guards shall be located along open-sided walking surfaces,that are located mare than 30 inches measured ❑ <br /> i vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. <br /> i Guards below are depicted vertically as an example only. <br /> handrail Ott)sides <br /> Less than 4" 34"-38- <br /> 36-min - <br /> 3'x 3'min <br /> — --' -: <br /> landing <br /> .L'x.t olio <br /> landing <br /> 3' One unit vertical in twelve units huriamtal <br /> ~ minimum is as 8.3%slope all along surface of the ramp. rnirlintl+m <br /> Implementation Date: 2021 February 01 <br /> Updated: 2021 February <br /> A <br />