15 <br />Electrician Handout <br />Electrician Installation Steps <br />Run AC cable and conduit to the box <br />according to NEC Article 300 and any <br />applicable local codes. The gland <br />accepts ½” conduit <br />Open the box using hinges <br />Connect AC Mains per wiring diagram <br />below: <br />Connect AC Neutral wire to the Surge Protector white Neutral wire using the <br />open position on the lever nut <br />Connect AC Line wire to the Surge Protector black Line wire using the open <br />position on the lever nut <br />Connect AC Ground wire to the Surge Protector green ground wire using the <br />open position on the lever nut. <br />4. Verify that both the RED LED is lit on the front of the box<br /> <br />5. Close box and zip tie the box shut with the provided zip tie<br /> <br />6. While still on-site, call Flock, who will remotely verify that power is working