Laserfiche WebLink
AI d,..,.ro we.cote..PPee.,1 .� <br /> FLOOR he <br /> B' 32,3" I . am <br /> PLAN LEGEND <br /> d ..end <br /> no <br /> ,m'nk .d or _ <br /> dmd .o,.... :.. en consent <br /> .L. .re.d..nne, <br /> I EXISTING WALL TO REMAIN REVISIONS <br /> DESCRIPTION of <br /> R INDICATES NO WORK AREA DATE 'REVISION <br /> 11/4 <br /> "—GUARDRAIL PER 11A2.0 ON THIS SHEET J I <br /> NEW DECK I 1 <br /> I , <br /> \ " a ii 1 - . L <br /> . <br /> • <br /> II. - - - <br /> . <br /> _ GENERAL NOTES Drawn By - <br /> 0 <br /> Checked By <br /> NEC ARTICLE 210(E)(3)BALCONIES,DECKS,AND PORCHES BALCONIES,DECKS,AND PORCHES THAT Job It <br /> ARE ACESSIBLE FROM INSIDE THE DWELLING UNIT SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET <br /> , _ INSTALLED WITHIN THE PERIMETER OF THE BALCONY DECK OR PORCH THE RECEPTACLE SHALL NOT <br /> BE LOCATED MORE THAN 6IA FT ABOVE THE BALCONY DECK OR PORCH SURFACE <br /> J <br /> 1! --GUARDRAIL PER 11AZ0 ON /, <br /> THIS SHEET I� R303 8-EXTERIOR STAIRWAY ILLUMINATION EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN <br /> UP - .,� (- } - (E) DECK ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY EXTERIOR STAIRWAYS <br /> , PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN I �� <br /> � . I ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY <br /> NEW DECK _ <br /> - _ <br /> EXISTING]NCi UPPER FLOOR PLAN IS R311 7 5 1-RISERS THE RISER HEIGHT SHALL BE NOT MORE THAN 7',INCHES(196 MM)THE RISER <br /> I FOR REFERENCE ONLYO - NOT I[\ \ / i SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS THE <br /> ��� GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE <br /> SCOPE OF WORK — VERIFY ALL )� `i= THAN 318 INCH(95MM)RISERS SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING <br /> / / OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES ID 51 RAD)FROM THE VERTICAL OPEN <br /> SMOKE,CARBON MONOXIDE DETECTORS RISERS ARE PERMITTED PROVIDED THAT THE OPENINGS LOCATED NOT MORE THAN 30 INCHES(762 MM) <br /> ADD REPLACE PER CODE AS NEEDED ] _ AS MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW DO NOT PERMIT THE PASSAGE OF A <br /> 4-INCH-DIAMETER 1102 NAM)SPHERE SEE EXCEPTIONS 11 <br /> $0 <br /> L. I r——_, 'f Y o <br /> 00 <br /> R311 7 5 2-TREADS DEPTH THE TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES(254 MM)THE TREAD rn <br /> DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PANES OF THE FOREMOST U r <br /> PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD S LEADING EDGE THE UJ w <br /> GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE 0 w <br /> 11 ,I THAN 316 INCH(9 5 MM)SEE EXCEPTIONS > <br /> w <br /> I', ON I <br /> Nh - 1 H tom- l- !- — J U) ¢ <br /> r:t I- <br /> R3121 GUARDS WHERE REQUIRED GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING yco <br /> O= <br /> SURFACES INCLUDING STAIRS RAMPS AND LANDINGS THAT ARE LOCATED MORE THAN 30 INCHES(762 E I _ <br /> 4 H MM)MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW A'ANY POINT WITHIN 36 INCHES(916 Z Q w <br /> MM)HORIZONTALLY TO THE EDGE OF THE OPEN SIDE INSECT SCREENING SHALL NOT BE CONSIDERED u 1n <br /> AS A GUARD N W m <br /> O <br /> I I. Q V) v <br /> R312 1 2 HEIGHT REQUIRED GUARDS AT OPEN-SIDED WALKING SURFACES INCLUDING STAIRS <br /> PORCHES BALCONIES OR LANDINGS SHALL BE NOT LESS THAN 36 INCHES(914 MM)IN HEIGHT AS <br /> MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SJRFACE OR THE LINE CONNECTING THE <br /> LEADING EDGES OF THE TREADS SEE EXCEPTIONS <br /> p �p c }''�_/ R312 1 3 OPENING LIMITATIONS REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING CO <br /> PROPOsr� UPPER FLOOR DECK PLAN SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OFA SPHERE 4-INCHES(102 MM)IN <br /> ' o • a e 4 • 0 4'-0"MAX SPACING X 6'-0.MAX SPACING DIAMETER SEE EXCEPTIONS F <br /> BETWEEN POSTS "I BETWEEN POSTS w <br /> za,3o sra_E 1 a• = t-o• <br /> TOP RAIL MUST RESIST--, I z <br /> z <br /> 200$CONCETRATEO ) IQ <br /> LOAD PER MFR OR I <br /> PROVIDE(4)16d NAILS @ O. <br /> Y <br /> EA POST I <br /> OPENINGS SHALL NOT C..) <br /> !' ALLOW THE PASSAGE w <br /> \ II OF A 4'0 SPHERE ❑ <br /> CABLES SHALL BE ) III <br /> SPACED 3'0/c <br /> I• <br /> • t <br /> I x <br /> • <br /> Q' ' Approval Stamp <br /> O <br /> F <br /> Z_ <br /> at <br /> nl <br /> I �-., <br /> II X <br /> Sheet <br /> GURADRAIL PREVENTING A 30'FALL OR MORE <br /> 1 TYP. GUARDRAIL <br /> A2.0 SCALE 1"=1'-0" A2.0 <br />