My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3310 HILL AVE 2023 Plans 2024-06-11
>
Address Records
>
HILL AVE
>
3310
>
Plans
>
3310 HILL AVE 2023 Plans 2024-06-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2024 11:41:20 AM
Creation date
6/11/2024 11:40:44 AM
Metadata
Fields
Template:
Address Document
Street Name
HILL AVE
Street Number
3310
Permit
B2309-061
Year
2023
Notes
INSTALL SPRAYTECH TDDCE0311 BOOTH, PAINT MIXING ROOM & EQUIP
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 I 3 V 2 I 1 <br /> GAS TRAIN SPECS CODE INFORMATION <br /> BTU/HR MAX GAS REQ'D(CFH) GAS PRESSURE TEMP.RISE GAS TRAIN INLET <br /> PIPE SIZE Spray Enclosure Technologies offers a complete line of spray booths that conform to the <br /> B 1.0MBTU/1.5MBTU 1000/1500 8"-14"W.C. 85.100 F° 1.0"/1.5" requirements of: B <br /> *NFPA-33 Standard for spray application using flammable and combustible materials. <br /> *NFPA-86 Standard for ovens and furnaces. <br /> *NFPA-91 Standard for exhaust systems for a conveying of materials. <br /> *NFPA101 Life safety code. <br /> LIGHTING ELECTRICAL SPECIFICATIONS *NFPA-70 National electric code. <br /> QTY. VOLTAGE FULL LOAD AMPS DESCRIPTION *OSHA Safety and health standards (29CFR 1910, 1910.107). <br /> 16 208-277V 0.43-0.32A Per Fixture 5-Strip LED Light Fixture *IFC/CFC International Fire Code/California Fire Code. <br /> *IBC/CBC International Building Code/California Building Code. <br /> *SBCCI Standard fire prevention code&Standard Building Code. <br /> *IFGC International Fuel Gas Code. <br /> *IEC International Energy Code. <br /> FILTER DATA <br /> QTY LOCATION EFFICIENCY FILTER DESCRIPTION All light fixtures are ETL listed.All Class 1 Division 2 lights are inside access and conform to the <br /> o Self supporting Duratlex media from virgin fiber.Frame constructed from the highest wet provisions of N.F.P.A. 3 3 and UL 844. <br /> 4 - Pre-Filter 100/o on 10 Microns strength 28 pt.beverage carrier board available.UL 900 Class 1 and Class 2. < <br /> 3 Intake 90%on 10 Microns Manuf.from thermally bonded synthetic fibers.Self extinguishing,UL 900 Class 1 and Class 2. Electrical components,such as motors,motor starters,disconnect switches and push buttons, <br /> 2 Exhaust 99.06%avg• Exhaust Cone Sock Filter are listed or approved for the Class and Division in which they are located. <br /> All glass used in Main Doors,Personnel Doors,and Light Fixtures are tempered and meets or <br /> exceeds ANSI Z-97.1 standard. <br /> FAN AND BLOWER DATA Conformance to allow these requirements is dependent on the manner in which the equipment <br /> FULL LOAD AMP DRAW,3PH is installed and used.The contractor will make certain that all of the electrical wiring and conduit, <br /> DESCRIPTION CFM @ inWC 208-230V 460V 575V piping,gas supply,roof penetrations,automatic fire protection systems,and the locations of the <br /> equipment within the building also conforms to the cited codes and other references. <br /> One(1)AMU Blower with 7.5HP 3PH Motor 12,000 @ 0.9 19.9-18.4A 9.18A 7.34A <br /> Fire suppression is NOT included with the standard booth but is required by NFPA-33. <br /> One(1)32"Fan with SHP 3PH Motor 17,200 @ 0.625 14.3-12.9A 6.45A 5.16A <br /> A A <br /> PART • <br /> APPROVED BY: DATE: <br /> :}‹ FSPRfly_ T[CAI NUMBER 2 TDDCE311 <br /> J DESCRIPTION: THERMAIR DOWNDRAFf CORNER EX 31' APPROVED BY: DATE: <br /> WWW.spraytech.com CREATION DATE: DRAWING : TDDCE31 1-Spec.idw <br /> 3/19/2018 NUMBER <br /> 4 3 A 2 I <br /> DAVIS SIGN CO. 3310 Hill Avenue SprayTech TDDCE311 spray booth - Specs 2 09.03 .23 Page 3 <br /> 206.287.9800 www.davissign.com <br />