. 4 I 3 V 2 I 1 <br /> B CODE INFORMATION B <br /> LIGHTING ELECTRICAL SPECIFICATIONS Spray Enclosure Technologies offers a complete line of spray booths that conform to the <br /> , requirements of: <br /> QTY. VOLTAGE FULL LOAD AMPS DESCRIPTION <br /> *NFPA-33 Standard for spray application using flammable and combustible materials. <br /> 4 208-227V 0.43-0.32 Per Fixture 5-Strip LED Light Fixture *NFPA-86 Standard for ovens and furnaces. <br /> *NFPA-91 Standard for exhaust systems for a conveying of materials. <br /> *NFPA1o1 Life safety code. <br /> *NFPA-70 National electric code. <br /> *OSHA Safety and health standards(29CFR 1910,1910.107). <br /> *IFC/CFC International Fire Code/California Fire Code. <br /> *IBC/CBC International Building Code/California Building Code. <br /> *SBCCI Standard fire prevention code&Standard Building Code. <br /> *IFGC International Fuel Gas Code. <br /> FILTER DATA *IEC International Energy Code. <br /> QTY LOCATION EFFICIENCY FILTER DESCRIPTION All light fixtures are ETL listed.All Class 1 Division 2 lights are inside access and conform to the <br /> 2 Intake 90%on 10 Microns Manuf.from thermally bonded synthetic 20"fibxers. <br /> 20"Self extinguishing,UL 900 Class 1 and Class 2. provisions of N.F.P.A.33 and UL 844. <br /> x2" <br /> Electrical components,such as motors,motor starters,disconnect switches and push buttons, <br /> are listed or approved for the Class and Division in which they are located. <br /> All glass used in Main Doors,Personnel Doors,and Light Fixtures are tempered and meets or <br /> exceeds ANSI Z-97.1 standard. <br /> Conformance to allow these requirements is dependent on the manner in which the equipment <br /> FAN AND BLOWER DATA is installed and used.The contractor will make certain that all of the electrical wiring and conduit, <br /> piping,gas supply,roof penetrations,automatic fire protection systems,and the locations of the <br /> FULL LOAD AMP DRAW,3PH equipment within the building also conforms to the cited codes and other references. <br /> DESCRIPTION CFM @ inWC <br /> 208-230V 460V 575V <br /> Fire suppression is NOT included with the standard booth but is required by NFPA-33. <br /> 9.188"Diameter Blower Wheel wl 1HP Motor 450 @ 0.25 3.67-3.32A 1.66A 1.33A <br /> A A <br /> PART MODEL APPROVED BY: ' DATE: <br /> < [�S P R h Y I C}� NUMBER • M R 150608 NUMBER: M R 150608 <br /> DESCRIPTION: Paint Mixing Room, 15'L x 6'W x 8'H,(4)LED Fixtures APPROVED BY: DATE: <br /> www.spraytech.com CREATION DATE: <br /> 5/11/2018 <br /> 4 1 3 A 2 I <br /> DAVIS SIGN CO. 3310 Hill Avenue SprayTech MR150608 Paint Mixing Room - Specs 1 09.03.23 Page 6 <br /> 206.287.9800 www.davissign.com <br />