5413 PARKVIEW LN 2023 Plans 2024-06-11
>
Address Records
>
PARKVIEW LN
>
5413
>
Plans
>
5413 PARKVIEW LN 2023 Plans 2024-06-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2024 2:31:14 PM
Creation date
6/11/2024 12:00:11 PM
Metadata
Fields
Template:
Address Document
Street Name
PARKVIEW LN
Street Number
5413
Permit
B2309-078
Year
2023
Notes
REMOVE EXISTING DECK AND INSTALL NEW DECK
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MyBuildingPermit.com <br /> a service of eCrtyGov.net Construction Tip Sheet 05 <br /> EXTERIOR SHEATHING ...,reek, <br /> EXISTING STUD WALL <br /> Existing 2x BAND JOIST ,,,-�1 <br /> OR ENGINEERING RIM .�—• <br /> BOARD :—rr � -`- <br /> Y MIN 1111 <br /> iTII...', DECK JOIST <br /> 5.MAX fit 111 . LAG SCREWS OR BOLTS <br /> Y fhlN` =fiiim. <br /> .• <br /> ° _�• :i'° 44 <br /> JOIST HANGER <br /> Lag screw or bolt Stagger fasteners in 2 rows <br /> 2"min. _Ad <br /> . — . 51/2"min.for 2x8* <br /> t 61/2"min.for 2x10 <br /> 5" <br /> max. 7 1/2"min.for 2x12 <br /> \ 3/4"min. <br /> Ledger *Distance can be reduced to <br /> 2"min. 4 1/2"if lag screws are used or <br /> Minimum edge distance for if bolt spacing is reduced to <br /> specialized screws.See that of lag screws to attach 2x8 <br /> manufacturer's technical bulletin. ledgers to 2x8 band joists <br /> Detail 1 — Ledger Attachment for Lateral Loads <br /> (Knee braces are required on posts greater than 4 feet in height) <br /> Hold-down or Sheathing <br /> tension device Siding <br /> with 1500# <br /> capacity Floor sheathing nailing Flashing <br /> at 6"o.c.(max)to joist t <br /> 110 <br /> withhold-down. Decking <br /> Flashing <br /> Joists j siroms <br /> — <br /> Joist Hangers j r t rr <br /> r....amir <br /> bilMi, ikills <br /> ..i 1 ►.., Treated 2x ledger ANION <br /> l�i1 2°min. <br /> jii ill■ I! <br /> Deck Joist I ►"4 <br /> Floor joist 750#capacity hoiddown device <br /> at 4 locations evenly distributed ipi Floor joists <br /> along the deck and within 2 ft of <br /> each end.Install per manufacturer <br /> Option # 1 Fully threaded 318"diameter lag screw <br /> p predrilled with a minimum of 3 in Option #2 <br /> embedment into solid framing. <br /> January 14,2022 MyBuildingPermit.com I Basic Deck <br /> , <br /> eCityGov:net <br /> MI5 eCINGo,AJliance <br />
The URL can be used to link to this page
Your browser does not support the video tag.