TESTING & INSPECTION <br />Y <br />CONTINUOUS SPECIAL INSPECTION IS REQUIRED DURING INSTALLATION PER 2018 IBC SECTION 1810.4.12. <br />THE SPECIAL INSPECTOR IS RESPONSIBLE FOR VERIFYING AND RECORDING THE FOLLOWING: <br />• PROJECT DESCRIPTION (ADDRESS, INSTALLATION DATE, PERMIT NUMBER <br />• PILE AND BRACKET CONFIGURATION <br />• PART DESCRIPTION (PRODUCT MANUFACTURER, BRACKET TYPE, PIER TYPE, PIER OUTSIDE DIAMETER, <br />PIER WALL THICKNESS) <br />• PIER INCLINATION, LOCATION, DEPTH, AND INSTALLATION PRESSURE ACHIEVED <br />LOAD TESTING SHALL BE <br />PERFORMED IN ACCORDANCE WITH ASTM METHOD D1143 (QUICK <br />METHOD) ON 20 <br />PERCENT OF PIERS AND <br />WILL BE SELECTED BY THE SPECIAL INSPECTOR. AN ALIGNMENT <br />LOAD (AL) SHALL <br />BE APPLIED TO THE PILE <br />PRIOR TO SETTING THE DEFLECTION MEASURING EQUIPMENT TO <br />ZERO OR A <br />REFERENCE POSITION. THE AL SHALL BE NO MORE THAN 10% OF THE DESIGN LOAD. INCREMENTAL <br />LOADING SHALL BE IN ACCORDANCE WITH THE FOLLOWING SCHEDULE. <br />TEST LOADING SCHEDULE <br />HOLD TIME MAX <br />DEFLECTION <br />AL (.10 DL MAX) <br />0 MIN. <br />0.25 DL <br />UNTIL STABLE <br />0.50 DL <br />UNTIL STABLE <br />0.75 DL <br />UNTIL STABLE <br />1.00 DL <br />UNTIL STABLE <br />1.25 DL <br />UNTIL STABLE <br />1.50 DL <br />HOLD FOR CREEP TEST (SEE BELOW) 0.04 <br />INCHES <br />1.25 DL <br />UNTIL STABLE <br />1.00 DL <br />UNTIL STABLE <br />0.75 DL <br />UNTIL STABLE <br />0.50 DL <br />UNTIL STABLE <br />0.25 DL <br />UNTIL STABLE <br />LOAD TESTING CREEP ACCEPTANCE CRITERIA SHALL BE NO GREATER THAN 0.04 INCHES WITHIN A 10 <br />MINUTE PERIOD. IF MOVEMENT IS OBSERVED GREATER THAN 0.04 INCHES WITHIN THE 10 MINUTE PERIOD <br />THE LOAD TEST SHALL BE HELD FOR AN ADDITIONAL 50 MINUTES, THE PIER IS TO BE DEEPENED AND <br />RE -TESTED, OR THE PIER IS TO BE ABANDONED AND REPLACED WITH A NEW PIER. IF THE LOAD TEST IS <br />TO BE HELD THE PIER MOVEMENTS SHALL BE MEASURED AT 15, 20, 30, 40, 50, AND 60 MINUTES. THE <br />CREEP VERSUS THE LOGARITHM OF TIME SHALL BE PLOTTED. IF THE CREEP RATE IS LESS THAN 0.080 <br />INCHES BETWEEN 6 AND 60 MINUTES, THE LOAD TEST SHALL BE CONSIDERED SUCCESSFUL. <br />PUSH PIER TEST PRESSURE (PSI): [DESIGN LOAD] X 1.5 / [AREA OF HYDRAULIC RAM]. <br />SAFEBASE STABILIZER SYSTEM INFO <br />PART <br />DESCRIPTION <br />COMMENTS <br />MIN YIELD <br />STRESS, Fy <br />MIN TENSILE <br />STRESS, F. <br />ASTM A36 R /2x6xO'-6" W/ (4) /g"0 HOLES W/ WELDED <br />WOOD BEAM <br />36 KSI <br />58 KSI <br />TOP R <br />1 '/4"Ox1 l/2" IPS SCH 40 ASTM A53 PIPE <br />CONDITION <br />30 KSI <br />48 KSI <br />1 /40"-7x12" ASTM A193 GRADE 87 THREADED ROD W/ <br />THREADED ROD <br />75 KSI <br />125 KSI <br />11/40"-7 ASTM A194 GRADE 2H HEX NUT <br />HSS 4x4x3/16x0'-4" ASTM A500 GRADE B/C HD GALV PER ASTM <br />46 KSI <br />58 KSI <br />THREADED CAP <br />A123 W/ WELDED R3/4x4x0'-4" ASTM A36 & 11/4"0-7 ASTM 194 <br />36 KSI <br />58 KSI <br />GRADE 2H HEX NUT <br />V/4x6xO'-6" ASTM A36 W/ (2) HOLES W/ WELDED HSS <br />36 KSI <br />58 KSI <br />BASE <br />4x4x3/1 xO'-2" ASTM 500 GRADE B/C HD GALV PER ASTM A123 <br />46 KSI <br />58 KSI <br />ASTM A500, GRADE B/C HD GALV, PER ASTM A123 <br />MAIN TUBE <br />HSS 31/2x31/2x11GA <br />46 KSI <br />58 KSI <br />NOTE: <br />INSTALL PER MFR RECOMMENDATIONS <br />CITY OF EVERF1T <br />i EVIEU D FOR PE M 1 <br />afa <br />SFA Uesign Group, LLC <br />STRUCTURAL ENGINEERING <br />p: (503�64tA311 � wwx.sfaEg.wm <br />U <br />J <br />J <br />Z <br />Q Z <br />n Z_ <br />W m <br />cc W� W N <br />O Dorn <br />F- cW.> � <br />W�F- <br />z 0 W <br />W <br />cr Lo W <br />O <br />LL w <br />J <br />LL <br />W IL <br />> Y <br />Q <br />GENERAL NOTES <br />(REVISIONS 1 <br />PROJECT NO: <br />MFR23-244 <br />DESIGNED BY: <br />JB <br />DRAWN BY: <br />JB <br />CHECKED BY: <br />JSF <br />DATE: <br />12.13.2023 <br />SHEET NO: <br />S1,2 <br />