BACKWARDS COMPATIBILITY TECHNICAL SPECIFICATIONS (cont'd) <br /> The AEGIS 2.0 is backwards compatible and listed for One (1)Abort Circuit <br /> use with a full range of conventional detectors and alarm -Compatible with normally open contact-closure type <br /> devices as well as suppression accessories from Kidde, devices <br /> Fenwal and Chemetron. Going forward, this will allow - Configurable as Class A/Style D or Class B/Style B <br /> legacy panels to be replaced with relative ease. - Supervised for ground faults and open circuits <br /> EASY TO INSTALL CABINET - Six (6)Abort Modes available <br /> The cabinet design allows for easy installation by fitting - Power-limited <br /> between the studs of a standard 16 inch studded wall. It Two (2) Supervisory Circuits <br /> is large enough to house two 12 VDC, 12 AH Batteries -Compatible with normally open contact-closure type <br /> and provides up to 2 inches (51 mm) of wiring and finger devices <br /> space between the circuit board and the cabinet wall. - Configurable as Class A/Style D or Class B/Style B <br /> An optional door design features a Manual Release and - Option to use SUP 1 as 4th detection circuit <br /> Abort switch for applications with space constraints. Both - Supervised for ground faults and open circuits <br /> switches incorporate guards that prevent their - Power-limited <br /> inadvertent activation. Three (3) Notification Appliance Circuits (NACs) <br /> TECHNICAL SPECIFICATIONS - Compatible with polarized 24 VDC Audio-Visual <br /> Hazards Protected devices <br /> • - Rated at 1.5 Amps each <br /> - One - Up to 35 synchronized appliances <br /> • Power Supply - Configurable as Class A/Style Z or Class B/Style Y <br /> - 120/240 V, 50/60 Hz (90 to 264 Vrms, 47 to 63 Hz) - Supervised for ground faults, shorts, and open <br /> AC Main Input circuits <br /> -5.4 Amps at 27 VDC Output - Power-limited <br /> - Battery capacity up to 68 AH @ 24 VDC - Common NAC/ARC output disconnect switch <br /> -Auxiliary power output rated at 1 Amp at 18.8-27.6 Two (2) Agent Release Circuits <br /> VDC (resettable) - Each compatible with 1 or 2 control heads, or 1 <br /> • Three (3) or Four(4) Detection Circuits actuator/initiator, or 1 FM sprinkler solenoid <br /> -Compatible with 700 Series, CPD-705x, PSD-715x, - Circuits electrically capable of simultaneously <br /> and THD-705x detectors as well as Normally Open releasing any combination of two of the above <br /> contact closure type devices. Refer to documents devices <br /> K-70-100 and F-70-63 for details on compatibility - Factory configured as Class B/Style Y <br /> and the maximum number of devices supported. - Supervised for ground faults and open circuits <br /> - Configurable as Class A/Style D or Class B/Style B - Default setting: Power-Limited. Each solenoid on a <br /> - Supervised for ground faults and open circuits power-limited ARC requires the use of an in-line <br /> - Power limited releasing device, P/N 06-220023-001 (order <br /> - DET 1 and DET 2 used for suppression separately, not included with panel). <br /> - DET3/WF configurable for detection or waterflow - Common NAC/ARC output disconnect switch <br /> - Option to use SUP 1 circuit as DET 4 circuit Four(4) Relays <br /> • One (1) Manual Release Circuit - 3 independently programmable, normally de- <br /> -Compatible with normally open contact-closure type energized Form-C Relays <br /> devices - 1 dedicated normally energized Form-C Trouble <br /> - Configurable as Class A/Style D or Class B/Style B Relay <br /> - Supervised for ground faults and open circuits - Relay contacts rated 3 Amps at 30 VDC/120 VAC <br /> - Power limited (resistive) <br /> - 4 - <br />