Laserfiche WebLink
WIRING DIAGRAMS 3. Contact Kidde for Installation Instruction sheets on <br /> these products. These materials contain important <br /> information that should be read prior to specifying or <br /> MT SIGNAL <br /> PROM installing these products, including: <br /> PRECEDING + + TO NEXT <br /> APPLIANCEAPPLIANCE Total current required by all devices connected to <br /> SM/DSMSM - - OR EOLR <br /> OR FACE system primary and secondary power sources. <br /> • Fuse ratings on signaling circuits to handle maxi- <br /> mum inrush or peak currents from all devices on <br /> those circuits. <br /> SIG""` • Composite flash rate from multiple strobes within <br /> a person's field of view. <br /> AUDIBLE SIGNAL AND STROBE Installation in office areas and other specification <br /> OPERATE INDEPENDENTLY and installation issues. <br /> FROM Use strobes only on circuits with continuous) <br /> PRECEDING + + TO NEXT y y <br /> AUDIBLE OR APPLIANCE <br /> FACP - - OR EOLR applied operating voltage. Do not use strobes on <br /> FROM + + TG NEXT coded or interrupted circuits in which the applied <br /> PRECEDING <br /> APPLIANCE, STROBE <br /> OR FACE - - OR EOLR voltage is cycled on and off, as the strobe may <br /> not flash. <br /> • The voltage applied to these products must be <br /> + - :04 <br /> + within their rated input voltage range. <br /> • Conductor size (AWG), length and ampacity <br /> STROBE AUDIBLE should be taken into consideration prior to design <br /> and installation of these products, particularly in <br /> AUDIBLE SIGNAL AND STROBE retrofit installations. <br /> OPERATE IN UNISON,RED AND 4. These notification appliances must be used within <br /> BLACK SHUNT-WIRES ARE their published specifications and must be PROP- <br /> SUPPLIED. <br /> ERLY specified, applied, installed, operated, main- <br /> PRECEDING + RED + TO NEXT <br /> APPLIANCE, _ APPLIANCE tained and operationally tested in accordance with <br /> OR FACP BLACK - OR EOLR <br /> their installation instructions at the time of installa- <br /> tion and at least twice a year or more often and in <br /> + - 0 + - accordance with local, state and federal codes, reg- <br /> ulations and laws. Specification, application, installa- <br /> STROBE AUDIBLE tion, operation, maintenance and testing must be <br /> performed by qualified personnel for proper opera- <br /> tion in accordance with all of the latest National Fire <br /> INSTALLATION NOTES Protection Association (NFPA), Underwriters' Labo- <br /> ratories (UL), National Electrical Code (NEC), Occu- <br /> 1. If the strobe and audible operate on the same cir- pational Safety and Health Administration (OSHA), <br /> cuit, add the strobe current from Table 2 to the audi- local, state, county, province, district, federal and <br /> ble current from Table 3. For Peak and Inrush other applicable building and fire standards, guide- <br /> current across the listed voltage range, refer to lines, regulations, laws and codes including, but not <br /> Installation Instructions. limited to, all appendices and amendments and the <br /> 2. The average current indicated is per actual Produc- requirements of the local Authority Having Jurisdic- <br /> tion Testing at listed VDC. For rated average and tion (AHJ). <br /> Peak current across the UL listed voltage range for <br /> both filtered DC and unfiltered VRMS, see Installa- <br /> tion Instructions. <br /> Failure to comply with the installation <br /> instruction sheets could result in improper <br /> © installation, application, and/or operation <br /> WARNING of these products in an emergency situa- <br /> tion,which could result in property damage <br /> and serious injury or death. <br /> - 3 - <br />