Laserfiche WebLink
NICET VERIFICATION _ <br /> FIRE PROTECTION ENGINEERING TECHNOLOGY ``- <br /> SPECIAL HAZARDS SYSTEMS LEVEL III DEVICE MOUNTING HEIGHTS " N <br /> NICET CERTIFICATE NUMBER 129522 N <br /> FLUSH MTD WITH CEILING <br /> C O E <br /> VALID THROUGH-JULY I,2025 IT a <br /> S H H S H 0 41 <br /> CEILING <br /> 09/22/2023 H C C 'a <br /> LOCATE CEILING MTD AN APPLIANCES ON BOTTOM OF CEILING,SUSPENDED CEILING. O r <br /> KYLE STUMP DATE BEAM,OR JOIST WITH CLEAR LINE OF SITE IN ALL DIRECTIONS,NO GREATER THAN O <br /> 30'A.F.F.(PENDANT MOUNT DOWN TO ACHIEVE 30'MAX). <br /> DETECTORS ARE MOUNTED FLUSH TO THE CEILING. w� <br /> uQ <br /> WALL <br /> zo <br /> H 30'MAX A.F.F. vQ <br /> ENTIRE LENS TO BE 80"A.F.F.NOT TO EXCEED 96" <br /> FSCP NACP 70"A.F.F.TO TOP OF DEVICE <br /> FAAP 60"A.F.F.TO TOP OF DEVICE <br /> F 48"A.F.F.TO TOP OF DEVICE <br /> E,HFINISHED FLOOR <br /> NOTE: <br /> "e FIRE ALARM PULL STATIONS SHALL BE MOUNTED AT+48"ABOVE <br /> FINISHED FLOOR TO TOP OF DEVICE. O <br /> FIRE ALARM INDICATING APPLIANCES SHALL BE PLACED 80"ABOVE THE 0 <br /> HIGHEST FLOOR LEVEL WITHIN THE SPACE OR 6"BELOW THE CEILING, N <br /> 1ST FLOOR DOCUMENT ROOM FSCP BATTERY CALCULATION WHICHEVER IS LOWER(REFER TO A.D.A.GUIDELINES). w <br /> STANDBY STANDBY ALARM ALARM LIJ <br /> CITY MODEL NUMBER DESCRIPTION CURRENT TOTAL CURRENT TOTAL Ur <br /> 1 AEGIS 20 MAIN BOARD 0.10000 0.10000 024000 024000 s- <br /> 1 DETECTICN Cl RCUTS#1 2&3 0.00000 0.00000 0.07000 0.07000 <br /> 3 711 U PHOTOELECTRIC SMOKE DETECTOR 0.00007 000021 000000 000000 WIRE LEGEND <br /> NAC OUTPUT#1 S1 0.00000 0.0000 VOLTAGE DROP NAC#1 S7 0.3300 Q <br /> NAC OLfTPUFF#2 F2 0.00000 0.0000 VOLTAGE DROP NAC#2 H2 0.1220 '6' NAC <br /> NAC OUTPUT#3 S3 0.00000 0.0000 VOLTAGE DROP NAC 93 S3 0.0600 O &1RED THHN BLACK <br /> 1 SOLENOID 0.00000 00000 070000 07000 <br /> 1 6871020000 PRE-ACTION SOLENOID 0.00000 0.0000 0.41700 0.4170 DETECTION <br /> TOTAL STANDBY(AMPS) 0.1002 TOTALALARM(AM°S) 1.5220 .. Q #16ga.TFFN WHITE <br /> &BLUE Z <br /> STANDBY HOURS 24 ALARM MINUTES 0.0830 ABORT L I J <br /> TOTAL STANDBY ANP HOU RS 2.4050 TOTAL ALARM AH 0.1263 #16ga.TFFN WHITE C <br /> TOTAL ANP HOURS 2.53,4 CLEAN AGENT PIPING ISO &BLUE L <br /> SAFETY FACTOR 20% 3.0376 MANUAL RELEASE <br /> #16ga.TFFN WHITE U <br /> SCAT E'.N.T.S. &BLUE <br /> PRESSURE SWITCH <br /> Point to Point Method Point to Point Method Point to Point Method #16ga.TFFN WHITE Q <br /> CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS &BLUE C <br /> TANK RELEASE W <br /> Circuit Number Si Source' AEGIS 2 0 Circuit Number H2 Source' AEGIS 2.0 Circuit Number S3 Source_ AEGIS 2 0 16ga.TFFN WHITE <br /> Nomnal System Voltage 20.4 Nominal System Voltage 20.4 Nomnal System Voltage 20.4 &BLUE <br /> DENOTES]EMT CONDUIT <br /> Minimum Deice Voltage 16 Minimum Device Voltage 16 Minimum Device Voltage 16 -- UNLESS NOTED mHERW156 <br /> Circuit Load Limit(1.5A Max) YES Wire Ohm's Circuit Load Limit(1.5A Max) YES Wire Ohm's Circuit Load Unit(1.5A Max) YES Wire Ohms SEE PUN SHEETS. Q >_Gau a Per 1000 Gauge Per 1000 Gauge Per 1000 (n E_ <br /> Distance from source to 1st device 35 14 307 Distance from source to tat deice 35 14 307 Distance from source to Tat deice F 50 14 3.07 J N <br /> Wire Gam for balance of circuit 14 3.07 Wire Gauge for balance of circuit 14 3 07 Wire Gau a for balance of circuit 14 3.07 z Q P <br /> Standard Wire Resistance in Ohms per 1000 feet_ Standard Wire Resistance in Ohms per 1000 feet. Standard Wire Resistance in Ohms per 1000 feet. m L.I.J <br /> nter current in arrps Distance Enter current in amps Distance oler current in amps Distance I (� <j <br /> .150=150 ma from Voltage .150=150 ma from Voltage .150=150 ma from Voltage Q <br /> Deice Device previous At Drop from Percent Device Device previous At Drop from Percent Device Deice previous At Drop from Percent Z Y LU <br /> Number Current device Device source Dro Numher Current deice Deice source Drop Number Current device Device source Drop <br /> LU Z Z Z <br /> Device 1 0.165 35 20.36 0.035 0.17% Device 1 0.122 35 20 37 0 026 0.13% Device 1 0.060 50 20.38 0.018 0.09% (� Q LU=LLI <br /> END 0.000 0 20.36 0.035 0.17% END 0 000 0 20 37 0 026 0.13% END 0 000 0 20 38 0 018 0 09% Qw 0 LI)Totals 0.165 0 End of Une Volta a 20.36 Totals 0.122 35 End of Line Volta a 20.37 Totals 0.060 50 End of Line Volta a 20.38 w J <br /> (n U cwi)N w <br /> s <br /> E <br /> IS <br /> ------- � STAFF ELEV 3 <br /> STAFF ELEV - <br /> 11005 r �, 11005 -a <br /> uTS 10 I I a <br /> _ L �" <br /> o � L L JJJ o�u <br /> a Hz <br /> - <br /> 3 0 a II CIRC - ig CIRC N <br /> °m w N AV 11011 AV <br /> N <br /> a 11011 r - -- -- ------ 1508 - -- -- ----- Q a <br /> 1` - x1508 - -- -- ------ - -- -- ------ <br /> REL#1 SOL '11 1�F 11 F <br /> GENERAL TROUBLE CONTACTS TO '-- DOC.STOR. <br /> C� TRBL DOC.STOR. <br /> BUILDING FIRE ALARM PANEL ® r 111509 <br /> FROM CNs 111509 <br /> _ <br /> BUILDING REL.#2 0v <br /> FACP a SUPERVISORY CONTACTS TO RLV.#3 0 F ------- <br /> FA <br /> J o <br /> (PROVIDED BUILDING FIRE ALARM PANEL FSCP TS <br /> TS N <br /> BY OTHERS) FIRE SUPPRESSION IQ II III <br /> GENERAL ALARM CONTACTS TO CONTROLPANEL - 1A .G- A <br /> BUILDING FIRE ALARM PANEL FLY.#2 KIDDE NAC.#3 8 LJ &SAEGIS 2.0 53-1 FS �� ® DRAWN BY: J.P.H <br /> 5CD ® - <br /> L-46 <br /> TO INTERPOSING RELAYS FOR SHUT dQSCV 1 ASOV`. MPOE CHECKED BY: K.S <br /> DOWN OF AHU/DAMPERS AS RLY.#1 l MPOE ISSUE DATE: 09/15/23 <br /> NAC.#2 11510 { <br /> REQUIRED H2-1 L 1151 U JOB#. <br /> JAN. ELEC. C JAN. ELEC. PROJECT#: 23915-JCI WF <br /> 11507 11511 11507 PRE-ACTION 111511 JOHNSONS CONTROL®2021 <br /> NAG.#1 PRE-ACTION SYSTEM: <br /> $1-1RISER TO BE <br /> 120V DEDICATED 75CD _ RISER TO BE D UPPRESSION GAS SYSTEM <br /> 7 AH 7 AH <br /> 12 V 12 V LOCATED IN <br /> POWER SUPPLY,F.B.O. LOCATED IN JANITORS <br /> SHEET: <br /> JANITORS CLOSET <br /> LOSET <br /> FIRE SUPPRESSION RISER DIAGRAM <br /> SCALE:N.T.S. 1ST FLOOR PBX ROOM 1ST FLOOR PBX ROOM r C <br /> S•2 <br /> CLEAN AGENT DEVICE PLAN CLEAN AGENT PIPING PLAN �� <br /> SCALE:1/8"=1'-O" �'\l/y SCALE:1/8"=1'-0" �' L/1 O <br /> 0 1 2 4 S IE 0 1 2 4 8 16 <br /> NORTH NORTH <br />