Laserfiche WebLink
NOTES: <br /> 1.Verify all conditions in the field. <br /> A Ir4l <br /> EXISTING OR NEW SHEATHING PER SCOPE OR AS l4j�Hicy 4 <br /> REQUIRED �R <br /> EXISTING OR NEW WEATHER-RESISTIVE BARRIER K I L B U R N <br /> SOLDER ALL SEAMS,TYP. <br /> EXISTING OR NEW VINYL SIDING TO MATCH EXISTING <br /> SELF-ADHESIVE FLASHING-FORTIFLASHBUM HEMMEDEDGE ?, EXISTING OR NEW SHEATHING AS REQUIRED ARCHITECTS LLC <br /> EXISTING WEATHER-RESISTIVE BARRIER <br /> EXISTING VINYL'J'CHANNEL WITH WEEP SCREED <br /> OR DRILL%e HOLES @ 12"O.C. <br /> EXISTING OR NEW SHEATHING,AS REQUIRED AND PER REMOVE AND RE-INSTALL(E)VINYL SIDING OR NEW AS REQUIRED, <br /> MATCH TO EXISTING 135 Lake Street South <br /> SCOPE NEW 24 GAUGE METAL SILL PAN,SITE VERIFY AND CONFIRM Suite 250 <br /> NEW CONTINUOUS 24 GAUGE METAL FLASHING e LAYOUT WITH ARCHITECT PRIOR TO FABRICATION Kirkland,WA 98033 <br /> EXISTING OR NEW WEATHER-RESISTIVE BARRIER TO y NEW 12"SELF-ADHESIVE FLASHING MEMBRANE(FORTIBER <br /> "FORTIFLASW OR EQUAL) <br /> MATCH EXISTING 12 Tel:206.682.5211 <br /> EXISTING OR NEW 1 X CEDAR BELLY BOARD TO MATCH - E Fax:206.682.1403 <br /> = EXISTING <br /> SILL PAN ISOMETRIC <br /> .� G. T —kilhurnarchitects.com <br /> EXISTING OR NEW VINYL SIDING TO MATCH EXISTING 95 DE <br /> [LEXISTING 0 R NEW VINYL'T CHANNEL W/WEEP SCREED OR DRILL <br /> ' p <br /> v3116"HOLES @ 12"O.C. <br /> EXISTING OR NEW 24 GA.METAL HEAD FLASHING,SEE DETAIL BELOW <br /> EXISTING OR NEW W.R.B AROUND END OF WALL INTERIOR FILLET REMOVE AND REINSTALL EXISTING SWING DOOR,SET 7302 <br /> EXISTING OR NEW SHEATHING PER SCOPE AND AS THRESHOLD IN TOE BEAD OF SEALANT,-DO NOT FASTEN REGISTERED <br /> REQUIRED EXISTING OR NEW VINYL 7'CHANNEL BEAD THROUGH PAN REMOVE AND RE-INSTALL EXISTING OR NEW TRIM ARCHITECT <br /> t m - WOOD TRANSITION STRIP <br /> AS REQUIRED NEW 24 GAUGE METAL SILL PAN SET IN BED OF SEALANT,SEE H,TODD KILBURN <br /> BACKER ROD AND SEALANT JOINT EXISTING FLOOR ISOMETRIC ABOVE STATE OF�ASHMGTON <br /> _ FINISH REMOVE AND RE-INSTALL EXISTING ENTRY DOOR AND FRAME <br /> NEW SELF ADHESIVE MEMBRANE FLASHING NEW WATERPROOF DECK COATING PER SCOPE-INSTALL PER <br /> EXISTING OR NEW CEDAR TRIM BOARD TO MATCH IF ORTIFIBER"FORTIFLASH"OR EQUAL).APPLY AROUND MANUFACTURER'S SPECIFICATIONS <br /> EXISTING,VERIFY IN FIELD CORNER,OVER WEATHER RESISTIVE BARRIER <br /> _ EXISTING OR NEW 1 X 4 CEDAR TRIM TO MATCH EXISTING, <br /> VERIFY IN FIELD <br /> NEW BACKER ROD AND SEALANT EXISTING OR NEW 1X CEDAR TRIM TO MATCH <br /> EXISTING,VERIFY IN FIELD SET IN TOE BEAD OF EXISTING OR NEW LIGHTWEIGHT SLOPE HORIZONTAL LEG T010°MIN. <br /> EXISTING OR NEW VINYL'J'CHANNEL SEALANT CONCRETE SLAB,REPAIR PER <br /> (E)FLOOR SHEATHING STRUCTURAL <br /> EXISTING OR NEW VINYL SIDING TO MATCH EXISTINGEXISTING OR NEW DECK SHEATHING V.I.F. <br /> EXISTING OR NEW W.R.B PER STRUCTURAL z C <br /> EXISTING OR NEW FLOOR EXISTING OR NEW DECK <br /> FRAMING PER STRUCTURAL FRAMING PER STRUCTURAL <br /> n Termination at Belly Band 2 Sidin Termination at End Wall 3 Swin Door Sill Pan 4 Swin Door Head Flashing <br /> Scale:3"=1'-0" Scale:3"=1'-0" Scale:3"=1'-0" Scale:3"=1'-0" <br /> Olin Fields Apartments <br /> Deck Repair <br /> 10115 Holly Dr. <br /> Everett,WA 98024 <br /> STRINGER PER STRUCTURAL <br /> FLASHING,AT DECK EDGE INTERSECTION WITH <br /> K NEW 24 GAUGE FULLY SOLDERED METAL SADDLE Release Date <br /> ADJACENTWALL permit 09.15.2022 <br /> REV.L 11.17.2022 <br /> REPAIR INTERIOR G.W.B.AS NECESSARY, REMOVE AND REPLACE AS REQUIRED <br /> PAINT TO NEAREST CHANGE IN PLANE = q, (E)PRECAST CONC.TREAD,TYP. <br /> EXISTING OR NEW SHEATHING AS REQUIRED <br /> ILBU Hrt:,,`.cr.r <br /> SADDLE FLASHING ISOMETRIC <br /> EXISTING WEATHER-RESISTIVE BARRIER <br /> (E)OR NEW WOOD RAILING PER STRUCTURAL <br /> REMOVE AND RE-INSTALL(E)VINYL SIDING OR NEW AS EXISTING END WALL OR <br /> REMOVE AND RE-INSTALL EXISTING REQUIRED,MATCH TO EXISTING COLUMN BEYOND NEW WATERPROOF DECK <br /> DOOR AND FRAME,PER SCOPE,PREP <br /> COATING PER SCOPE-INSTALL <br /> AND PAINT PER MANUFACTURER'S 4" <br /> EXISTING OR NEW VINYL'J'CHANNEL WITH WEEP 4' NEW WATERPROOF DECK COATING PER SCOPE- SPECIFICATIONS r -- <br /> . ,- v SCREED OR DRILL pie'HOLES @ 12'0.0 SLOPE INSTALL PER MANUFACTURER'S SPECIFICATIONS s <br /> NEW 24 GAUGE METAL DECK TO WALL FLASHING 1I4'I FT MIN. <br /> _ s 4.� NEW CONTINUOUS 24 GAUGE METAL FLASHING WITH :�y {' <br /> NEW WATERPROOFDECK COATING-INSTALL PER h...-. 's",_ .+.,.,.— —�^ NEW CONTINUOUS 24 GAUGE METAL FLASHING WITH <br /> " ^^ Y"HEMMED DRIP EDGE,PLANE TOPPING SLAB EDGE _-:'_____ - �__'' <br /> ___ :x <br /> MANUFACTURER'S SPECIFICATIONS ---------- -- :o '/z"HEMMED DRIP EDGE,PLANE TOPPING SLAB EDGE <br /> FT <br /> REMOVE AND RE-INSTALL EXISTING OR NEW = _ TO ACCEPT FLASHING TO PROVIDE CONTINUOUS <br /> CEDAR TRIM " EXISTING OR NEW LIGHTWEIGHT CONCRETE © sxaeuax nacxrtecrs,uc SLOPE TO DRAIN ©aar xaBuax nacxrtBcts,uc II TO ACCEPT FLASHING TO PROVIDE CONTINUOUS <br /> TOPPING SLAB PER STRUCTURAL SLOPE TO DRAIN <br /> NEW BACKER ROD AND SEALANT z (E)OR NEW DECK SHEATHING (E)OR NEW DECK SHEATHING <br /> PER STRUCTURAL PER STRUCTURAL II <br /> SLOPE 518'TYPE'X'GYPSUM BOARD <br /> EXISTING OR NEW VINYL'J'CHANNEL lU EXISTING BEAN <br /> NEW 9"VERTICAL JAMB FLASHING MEMBRANE(FORTIFIBER NEW WEATHER-RESISTIVE BARRIER <br /> 'FORTIFLASH'OR EQUAL)OR LIQUID-FLASHING EXTEND%" L -- --- -- — FRAMING PER E) <br /> (E)OR NEW DEC 5I8"TYPE'X'GYPSUM BOARD <br /> ONTO JAMB TRIM STRUCTURA FRAMING PER <br /> STRUCTU NEW W.R.B <br /> NEW OR EXISTING VINYL SIDING EXISTING 4X PT.BEAM <br /> (E)OR NEW SHEATHING PER <br /> EXISTING WEATHER-RESISTIVE BARRIERSTRUCTURAL ?"� ''•' '' - <br /> EXISTING SHEATHING ` <br /> EXISTING OR NEW CEDAR DECK FASCIA TO <br /> EXISTING OR NEW SHEATHING AS REQUIRED �(E)OR NEW FRAMING PER RE-USE EXISTING - RE-USE EXISTING MATCH EXISTING AS REQUIRED <br /> STRUCTURAL VENT VENT ' <br /> EXISTING OR NEW CEDAR DECK FASCIA TO <br /> MATCH EXISTING AS REQUIRED <br /> NEWIXCEDAR BEAM WITH ENTT MATOPSUM SOFFIT Details <br /> WITH VENT TO MATCH <br /> WRAP 5181 GYPSUM SOFFIT WITH VENT TO EXISTING <br /> MATCH EXISTING <br /> NEW 1 X CEDAR BEAM WRAP <br /> Swing Door Jamb Flashing Deck to Wall Flashing Breezway Edge Flashing Stair Landing Edge at Bottom of Stringer <br /> Scale:3"=1'-0" V Scale:3"=1'-0" Scale:3"=1'-0" Scale:3"=1'-0" <br /> A-2.3 <br /> ©­K1_N­ANCB1tBCTS,LLC <br />