Laserfiche WebLink
SOLAR PV SYSTEM DETAILS EXISTING EXISTING SUPPLY CALCULATIONS FEEDER SCHEDULE <br /> MODULE 1 MODULE 2 <br /> TOTAL MODULE(S) 42 MODULE MODEL LG LG435QAC-A6 ITEK MAIN PV IBUSBAR TOTAL SUPPLY% O ENPHASE Q CABLES+#6 BARE EGC IN OPEN AIR <br /> 270 HE 200 OA 200 0%5100% (2)#12 THWN-2+(1)#10 GND IN 3/4"EMT <br /> TOTAL DC POWER 14.78kW VM 41.10V 32.00V ® NOT USED <br /> Mpp 10.59A 8.40A a 2#8 THWN-2+ 1 #8 THWN-2 NEUT+ 1 #10 GND IN 1"EMT <br /> OPERATING VOLTAGE 240V V 48.00V 38.9oV NEW CONDUIT CURRENT CALCULATIONS O( ( ) ( ) <br /> 11.20A 9.1 OA #12 THWN-2 ALLOWABLE CURRENT 30A ® NOT USED <br /> MAX AC POWER OUT 12.08kVA ®(2)#6 THWN-2+(1)#6 THWN-2 NEUT+(1)#6 GEC IN 1"PVC <br /> V TEMP COEFF 0.24%/°C -0.29%/°C CURRENT CARRYING CONDUCTORS 4 0 0 <br /> MIN DESIGN TEMP -10°C -40°C ADJUSTMENT FACTOR 80% © NOT USED <br /> NEW PV SYSTEM ® NOT USED <br /> STRING SIZING DETAILS NEW MIRCO EXISTING ADJUSTED ALLOWED CURRENT 24A PUGET SOUND SOLAR <br /> STRING MAX MICROS 11 INVERTERS 1 INVERTER 2 1 STRING MAX AC OUTPUT CURRENT 11A FLAG NOTES: 805 Rainier Ave S <br /> STRING MAX INVERTER MODEL ENPHASE EITEKTHEIA MAIN BONDING JUMPER,LINE SIDE TAP BEFORE MAIN <br /> 1595A IQ7A-72-2-US 4.4 HE-T BREAKER IN COMPLIANCE WITH NEC 2020 705.11 Seattle, WA 98144 <br /> . <br /> CONTINUOUS OUTPUT MAX DC IN 58V 600V OV RCURR NT R TE 10 <br /> SYSTEM 2 MONITORING DEVICE CT LEADS,(2)18 AWG IN 1/2"EMT Tel: 206-706-1931 <br /> 22 MAX CURRENT IN 15A 21A AX AC OUTPUT 125%SAFETY OCPD SIZE 3 NOT USED <br /> MICROINVERTER TOTAL MAX AC OUT 349VA 4450VA °PV STRING MAX 19.94A 20A <br /> SYSTEM MAX AC 31.9A MAX-CURRENT OUT 1.45A 23A PV TOTAL 39.9A 40A NOT USED <br /> CONTINUOUS OUTPUT w x <br /> NOT USED �o <br /> oi )qEVO NE MI CO <br /> MODULE INVERTERS ©NOT USED 3 y a <br /> MODULE MODEL REC-410-AA-PURE INVERTER MODEL WA-72-2-US NEW K <br /> �o <br /> Mpp 42.70V MAX DC IN 58V 1 DAY <br /> I pp 9.61A MAX CURRENT IN 15A s o 9 <br /> Voc 49.00V MAX AC OUT 349VA a <br /> LEGEND <br /> 10:35:00 AM MAX CURRENT OUT 1.45A Q s o o <br /> V TEMP COEFF 0.24%/°C �_ GROUNDING 0 i <br /> IN DESIGN TEMP 2°C W d o <br /> EXISTING BREAKER z Q w� <br /> INVERTER 2 SOLAR MODULE Q @ <br /> EITEK THEIA 4.4 HE-T ❑J JUNCTION BOX W o �, So <br /> 18.5A MAX AC OUTPUT PRODUCTION J <br /> ��� <br /> O METER O LU <br /> OM NET METER U o g <br /> / oo <br /> EXISTING ® FUSED AC o 0. <br /> m c <br /> DISCONNECT <br /> 30A AC DISCONNECT UNFUSED AC o a <br /> + + EXISTING + + 1 DISCONNECT Nm�? <br /> STRING OF O DG* D0 MI MICROINVERTER = <br /> mmm <br /> 10 MODULE 2 DC OPTIMIZER Amo <br /> EXISTING o w <br /> 70A AC UTILITY Mo. <br /> + EXISTING O DISCONNECT ( SERVICE <br /> STRING OF _ <br /> 10 MODULE 2 EXISTING 40A <br /> IQ COMBINER <br /> NEW LOAD 0 PRELIMINARY DESIGN 1/324 <br /> O 200A CENTER REV DESCRIPTION DATE <br /> THIS STRING: 20A 200A MAIN DRAWN BY NN <br /> (7)LG 435(EXISTING)+(4)REC 410(NEW) ^ 0 200A BUS CHECKED BY BU <br /> 20A <br /> 0 0 o PROJECT#:21523 <br /> MI MI MI MI 10A SALES:ROY FOSTER <br /> STRING OF 3 O ^ PM: BILL ULSUND <br /> 1 M DU ES <br /> PM CELL:(253)951-0385 <br /> 0 <br /> MONITORING 25A <br /> 3 MI MI EXISTING MI MI O DEVICE o- ELECTRICALONELINE <br /> STRING OF <br /> 11 MODULES l <br /> ROOF EXTERIOR INTERIOR EXISTING <br /> PV-102 <br />