Laserfiche WebLink
Enphase IQ 7A Microinverter <br /> INPUT(DC) IQ7A-72-2-US <br /> Commonly used module pairings' 295 W-460 W+ <br /> Module compatibility 60-cell,66-cell,and 72-cell PV modules <br /> Maximum input DC voltage 58V <br /> Power point tracking voltage range 18 V-58 V <br /> Min/Max start voltage 30 V/58 V <br /> Max DC short circuit current(module ISc)3 15A <br /> Overvoltage class DC port II <br /> DC port backfeed current 0 A <br /> PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; <br /> AC side protection requires max 20A per branch circuit <br /> OUTPUT(AC) @ 240 VAC @ 208 VAC <br /> Peak output power 366 VA 295 VA <br /> Maximum continuous output power 349 VA 290 VA <br /> Nominal(L-L)voltage/range4 240 V/211-264 V 208 V/183-229 V <br /> Maximum continuous output current 1.45 A(240 VAC) 1.39 A(208 VAC) <br /> Nominal frequency 60 Hz <br /> Extended frequency range 47-68 Hz <br /> AC short circuit fault current over 3 cycles 5.8 Arms <br /> Maximum units per 20 A(L-L)branch circuits 11 (240 VAC) 11 (208 VAC) <br /> Overvoltage class AC port III <br /> AC port backfeed current 18 mA <br /> Power factor setting 1.0 <br /> Power factor(adjustable) 0.85 leading... 0.85 lagging <br /> EFFICIENCY @240 VAC @208 VAC <br /> CEC weighted efficiency 97.0% 96.5% <br /> MECHANICAL <br /> Ambient temperature range -40°C to+60°C <br /> Relative humidity range 4%to 100%(condensing) <br /> Connector type:DC(IQ7A-72-2-US) MC4 <br /> Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) <br /> Weight 1.08 kg(2.38 lbs) <br /> Cooling Natural convection—No fans <br /> Approved for wet locations Yes <br /> Pollution degree PD3 <br /> Enclosure Class II double-insulated,corrosion resistant polymeric enclosure <br /> Environmental category/UV exposure rating NEMA Type 6/outdoor <br /> FEATURES <br /> Communication Power Line Communication(PLC) <br /> Monitoring Enlighten Manager and MyEnlighten monitoring options <br /> Compatible with Enphase IQ Envoy <br /> Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break <br /> disconnect required by NEC 690. <br /> Compliance CA Rule 21 (UL 1741-SA) <br /> UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, <br /> CAN/CSA-C22.2 NO.107.1-01 <br /> This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and <br /> NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC <br /> and DC conductors,when installed according manufacturer's instructions. <br /> 1.No enforced DC/AC ratio.See the compatibility calculator at https7Henphase.com/en-us/support/module-compatibility. <br /> 2.CEC peak power tracking voltage range is 38 V to 43 V. <br /> 3.Maximum continuous input DC current is 10.2A. <br /> 4.Voltage range can be extended beyond nominal if required by the utility. <br /> 5.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. <br /> To learn more about Enphase offerings,visit enphase.com <br /> ©2019 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ E N P H A S E <br /> Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. `J <br /> 2019-11-07 <br />