MICROINVERTER SPECIFICATIONS SOLAR MODULE SPECIFICATIONS AMBIENT TEMPERATURE SPECIFICATIONS <br /> MANUFACTURER/MODEL# HOYMILES HM-150ONT(240V) MANUFACTURER/MODEL# SEG SOLAR YUKON SERIES SEG-410-BMD-HV RECORD LOW TEMP -5°C AHJ STAMP <br /> VMP 31.05V AMBIENT TEMP(HIGH TEMP 2%AVG.) 26°C <br /> INPUT POWER RANGE 30OW-505W IMP 13.21A <br /> MIN/MAX START VOLTAGE 22V/60V VOC 37.32V MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE 7/8" <br /> SOURCE:ASHRAE WEATHER DATA VIA <br /> NOMINAL AC VOLTAGE 240V ISC 13.80A HTTPS://ENERGYRESEARCH.UCF.EDU/SOLAR-CERTIFICATION/SOLAR-REFERENCE-MAP/ <br /> MAX CONT.OUTPUT CURRENT 5.99A TEMP.COEFF.VOC -0.27%/°C <br /> MAX CONT.OUTPUT POWER 11438W <br /> MAX MODULES PER STRING 116(4 MICROINVERTERS) <br /> MICROINVERTER SPECIFICATIONS <br /> MANUFACTURER/MODEL# HOYMILES HM70ONT(240V) <br /> INPUT POWER RANGE 28OW-47OW <br /> MIN/MAX START VOLTAGE 22V/60V <br /> NOMINAL AC VOLTAGE 240V <br /> MAX CONT.OUTPUT CURRENT 2.90A <br /> MAX CONT.OUTPUT POWER 696W <br /> MAX MODULES PER STRING 16(08 MICROINVERTERS) <br /> STRUCTURAL STAMP <br /> PROJECT NAME <br /> JOSH GOOD <br /> 1310 MAPLE ST, <br /> EVERETT,WA 98201 <br /> 4252100327 <br /> jsh_gd@yahoo.com <br /> APN#: 00438725802900 <br /> AHJ: CITY OF EVERETT <br /> UTILITY: TACOMA PUD <br /> REVISIONS <br /> REV DESCRIPTION DATE <br /> SHEET TITLE <br /> ELECTRICAL <br /> CALCULATIONS <br /> DESCRIPTION FORMULA RESULT <br /> DRAWN DATE 2/16/2024 <br /> PV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25=((02 x 5.99)+(01 x 2.90))A x 1.25 18.60A (SELECTED OCPD =30A) DRAWN BY SM <br /> TEMP QTY OF CURRENT MINIMUM CONDUCTOR CONDUCTOR REQUIRED CIRCUIT NEUTRAL <br /> EXPECTED WIRE CONDUIT FILL WIRE GAUGE& ADJUSTED CONDUCTOR GROUND WIRE <br /> WIRE ID DERATE CARRYING CONDUIT SIZE MPACITY @ 90° AMPACITY @ CONDUCTOR AMPACITY AMPACITY @ 90° SIZE&TYPE <br /> CONDUCTOR SHEET NUMBER <br /> TEMP(°C) (90°C) CONDUCTORS DERATE (TBD ON SITE) TYPE (A) 75°C(A) (A) C(A) SIZE&TYPE <br /> 1 26 1.00 2 1 3/4"METAL #10 THWN-2 40 35 18.60 40.00 NONE #10 THWN-2 PV-04. 1 <br /> 2 26 1.00 2 1 3/4" METAL #6 THWN-2 75 65 18.60 75.00 NONE #10 THWN-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.