CONTRACTOR <br /> AHJ STAMP <br /> PURELIGHT POWER NEWCO LLC NEW PHOTOVOLTAIC ROOF MOUNTED SYSTEM <br /> 3521 AVION DRIVE, SUITE#200, <br /> 4. 100 KW DC/3.572 KW AC <br /> MEDFORD, OREGON 975044 <br /> Purelight PHONE-(541)816-4047 1310 MAPLE ST, EVERETT, WA 98201 <br /> LIC. NO. -226333 <br /> 1. SIGN ROOF PITCH: 30,26 NEW PV SYSTEM SPECIFICATIONS APPLICABLE ALL WORK SHALDES <br /> L CONFORM TO THE FOLLOWING CODES: SHEET INDEX <br /> SYSTEM SIZE: DC SIZE:4.100 KW DC-(STC) <br /> 2.AZIMUTH: 270, 180 AC SIZE:3.572 KW AC 2018 INTERNATIONAL BUILDING CODE PV-00 GENERAL NOTES/DESIGN CRITERIA <br /> 3. MODULE: (10)SEG SOLAR YUKON SERIES 2018 INTERNATIONAL RESIDENTIAL CODE <br /> PROJECT NOTES PV-01 PROPERTY PLAN <br /> SEG-410-BMD-HV 1.1.1 THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH THE 2018 INTERNATIONAL EXISTING BUILDING CODE <br /> 4.INVERTER: 02 HOYMILES HM-150ONT 240V 2018 INTERNATIONAL FIRE CODE PV-02 SITE PLAN <br /> ( ) ( ) RELEVANT YEAR OF THE NATIONAL ELECTRIC CODE(NEC),ALL <br /> (01)HOYMILES HM70ONT(240V) MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS,AND THE 2020 NATIONAL ELECTRICAL CODE PV-03 ATTACHMENT PLAN&DETAILS <br /> 5. NOMINAL AMPERAGE: 14.88 RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING AS ADOPTED BY CITY OF EVERETT PV-03.1 FRAMING DETAIL STRUCTURAL STAMP <br /> 6.ROOF AREA: 3098.66 FTZ JURISDICTION'S(AHJ)APPLICABLE CODES. PV-04 ELECTRICAL DIAGRAM <br /> 7. PV ARRAY AREA: 210.23 FTZ 1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED PV-04.11 ELECTRICAL CALCULATIONS <br /> 8.PV ARRAY WEIGHT: 474.00 LBS AND THE PV SYSTEM MUST BE INSPECTED PRIOR TO OPERATION PV-05 I WARNING LABELS <br /> 9. ROOF SURFACE TYPE: COMPOSITE SHINGLE 1.1.3 ALL PV SYSTEM COMPONENTS;MODULES,UTILITY-INTERACTIVE SCOPE OF WORK PV-05.11 DIRECTORY PLACARD EVOR JpN <br /> 10. ROOF STRUCTURE: 2"X4"RAFTER @ 24"OC INVERTERS,AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND �� F WASH? FS' <br /> 1.2.1 CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EQUIPMENT DATASHEETS ATTACHED N <br /> 11. BUILDING STORY: ONE STORY LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC AND �� i'. G�, <br /> 12.SNOW LOAD: 15 PSF OTHER GOVERNING CODES SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM. `Q 0 <br /> Z <br /> 13.WIND SPEED: 92 MPH 1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING THE CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTION OF c <br /> VICINITY MAP � <br /> 14.WIND EXPOSURE: B CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT.ALL EXISTING ONSITE CONDITIONS TO DESIGN,SPECIFY,AND <br /> 15. RISK CATEGORY: II PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC INSTALL THE ROOF-MOUNTED PHOTOVOLTAIC SYSTEM <br /> AND AHJ. DETAILED IN THIS DOCUMENT m -10 201148 8 <br /> GENERAL NOTES N FSS�GIS N�\� <br /> SITE NOTES STRUCTURAL NOTES(CONT.) DISCONNECTION AND OVERCURRENT PROTECTION NOTES E ONALE <br /> 2.1.1 A LADDER WILL BE IN PLACE FOR INSPECTION IN 2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED 2.6.1 DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT 2/16/2024 <br /> ACCORDANCE WITH OSHA REGULATIONS. AND SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING STRUCTURAL ONLY <br /> 2.1.2 THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE CONTRACTOR. ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED"LINE <br /> AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO 2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER SIDE"(TYPICALLY THE UPPER TERMINALS). <br /> STORAGE BATTERIES. THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER 2.6.2 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY 1310 Maple St <br /> 2.1.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY OR PROFESSIONAL ENGINEERING GUIDANCE. PERSONNEL,BE LOCKABLE,AND BE A VISIBLE-BREAK SWITCH Everett,WA 98201, v PROJECT NAME <br /> PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. 2.3.5 WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WILL BE 2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLE United States JOSH GOOD <br /> 2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND STAGGERED AMONGST THE ROOF FRAMING MEMBERS. BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO <br /> EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN S 1310 MAPLE ST, <br /> PROVIDED IN ACCORDANCE WITH SECTION NEC 110.26. WIRING&CONDUIT NOTES ACCORDANCE WITH 690.12 w EVERETT,WA 98201 <br /> 2.1.5 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED,AND 2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR 2.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC <br /> MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM 690.8,690.9,AND 240. 4252100327 <br /> APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TO A jsh_gd@yahoo.com <br /> ROOF COVERING SERVES TO PROTECT THE BUILDING OR 2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S)IN SATELLITE MAP APN#: 00438725802900 <br /> STRUCTURE. 2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC ACCORDANCE WITH NEC 110.3(6). <br /> 2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED IN 2.6.6 IF REQUIRED BY THE AHJ,SYSTEM WILL INCLUDE ARC-FAULT ' AHJ: CITY OF EVERETT <br /> EQUIPMENT LOCATIONS ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR CIRCUIT PROTECTION IN ACCORDANCE WITH NEC 690.11 AND ' UTILITY: TACOMA PUD <br /> 2.2.1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS IN LABELING PER NEC UL1699B. <br /> ACCORDANCE WITH NEC 110.26. REVISIONS <br /> 2.2.2 WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE GROUNDING NOTES INTERCONNECTION NOTES <br /> RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED 2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR 2.7.1 LOAD SIDE INTERCONNECTION SHALL BE IN ACCORDANCE Q REV DESCRIPTION DATE <br /> BY NEC 690.31 (A),(C)AND NEC TABLES 310.15(13)(2)(A)AND 310.15 PURPOSE,AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL WITH NEC 705.12. <br /> (13)(3)(C). BE RATED FOR SUCH USE. 2.7.2 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS 1310MapleSt <br /> 2.2.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER 2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH NEC OUTPUT MAY NOT EXCEED 120 PERCENT OF BUSBAR RATING PER Everett,WA 98201, <br /> PV MODULES IN ACCORDANCE WITH NEC 690.34. 690.43 AND NEC TABLE 250.122. NEC 705.12. United States <br /> 2.2.4 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED 2.5.3 METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND 2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT <br /> WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCE WITH NEC CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE <br /> SERVICING DISCONNECT.2.2.5 ALL EQUIPMENT SHALL BE 250.134 AND 250.136(A). PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF <br /> INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL IN 2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED IN THE AMPACITY OF THE BUSBAR, PV DEDICATED BACKFEED i <br /> ACCORDANCE WITH NEC APPLICABLE CODES. ACCORDANCE WITH NEC 690.45 AND INVERTER MANUFACTURER'S BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM SHEET TITLE <br /> 2.2.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND INSTALLATION PRACTICES THE UTILITY SOURCE OCPD IN ACCORDANCE WITH NEC 705.12. GENERAL NOTES <br /> RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 2.5.5 EACH MODULE WILL BE GROUNDED AS SHOWN IN MANUFACTURER 2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER <br /> DOCUMENTATION AND APPROVED BY THE AHJ. 2.5.6 THE GROUNDING PANEL,TOTAL RATING OF ALL OVERCURRENT PROTECTION DEVICES <br /> STRUCTURAL NOTES CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE SHALL NOT EXCEED AMPACITY OF BUSBAR.HOWEVER,THE MAIN DESIGN CRITERIA <br /> 2.3.1 RACKING SYSTEM&PV ARRAY WILL BE INSTALLED IN REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING OVERCURRENT PROTECTION DEVICE MAY BE EXCLUDED IN <br /> ACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION CONDUCTOR TO ANOTHER MODULE. ACCORDANCE WITH NEC 705.12. DRAWN DATE 2/16/2024 <br /> MANUAL.TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN 2.5.7 GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE 2.7.5 FEEDER TAP INTERCONNECTION(LOAD SIDE)IN ACCORDANCE <br /> MODULES,AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE COLORED GREEN OR MARKED GREEN IF#4 AWG OR LARGER PER NEC WITH NEC 705.12. DRAWN BY SM <br /> BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, IN 250.119 2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCE WITH <br /> ACCORDANCE WITH RAIL MANUFACTURER'S INSTALLATION 2.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 TO NEC 705.11 WITH SERVICE ENTRANCE CONDUCTORS IN SHEET NUMBER <br /> PRACTICES. AND NEC 250.50 THROUGH 250.106.IF EXISTING SYSTEM IS INACCESSIBLE, ACCORDANCE WITH NEC 230.42. <br /> 2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S OR INADEQUATE,A GROUNDING ELECTRODE SYSTEM PROVIDED IN 2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES <br /> SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE ACCORDANCE WITH NEC 250,NEC 690.47 AND THE AHJ. OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING PER NEC 705.12. PV-00 <br /> FLASHED&SEALED PER LOCAL REQUIREMENTS. 2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) <br /> AND(2)TO REDUCE FIRE HAZARDS <br />