Laserfiche WebLink
IioILImileS <br />4 <br />Open Energy For All <br />Technical Specifications <br />Description <br />Hoymiles 2-in-1 microinverter can connect up to 2 panels at <br />once and maximize the PV production of your installation. With <br />a maximum DC voltage of 60 V, Hoymiles microinverter is a PV <br />Rapid Shutdown Equipment and conforms with NEC-2017 and <br />NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. <br />All of the three models listed are equipped with reactive power <br />control and can meet the requirements of IEEE 1547, UL 1741 <br />and CA Rule21. <br />Features <br />Easy installation, just plug and play External antenna for stronger <br />1 communication with DTU <br />With Reactive Power Control, compliant <br />with CA Rule 21 <br />1 High reliability: NEMA 6 (IP67) enclosure, <br />® Compliant with U.S. NEC-2017&NEC-2020 6000 V surge protection <br />1 <br />690.12 rapid shutdown <br />Region: North America .1 <br />o 2024 Hoymiles Power <br />Model <br />H M-60ONT <br />H M-70ONT <br />H M-80ONT <br />Input Data (DC) <br />Commonly used module power (W) <br />240 to 405+ 280 to 470+ 320 to 540+ <br />Maximum input voltage (V) <br />60 <br />MPPT voltage range M <br />16-60 <br />Start-up voltage (V) <br />22 <br />Maximum input current (A) <br />2 x 11.5 2 x 11.5 2 x 12.5 <br />Maximum input short circuit current (A) <br />2 x 20 <br />Number of MPPTs <br />2 <br />Number of inputs per MPPT <br />1 <br />Output Data (AC) <br />Peak output power (VA) <br />600 700 800 <br />Maximum continuous output power (VA) <br />590 696 766 <br />Maximum continuous output current (A) <br />2.46 2.84 2.90 3.35 3.19 3.68 <br />Nominal output voltage/rangeM' <br />240/211-264 208/183-228 240/211-264 208/183-228 240/211-264 208/183-228 <br />Nominal frequency/range (Hz)' <br />60/55-65 <br />Power factor (adjustable) <br />> 0.99 default <br />0.8 leading ... 0.8 lagging <br />Total harmonic distortion <br />< 3% <br />Maximum units per 10 AWG branch <br />9 8 8 7 7 6 <br />Maximum units per 12 AWG branch <br />6 5 5 4 5 4 <br />Efficiency <br />CEC peak efficiency <br />96.7% <br />CEC weighted efficiency <br />96.5% <br />Nominal MPPT efficiency <br />99.8% <br />Nighttime power consumption (mW) <br /><50 <br />Mechanical Data <br />Ambient temperature range (°C) <br />-40 to +65 <br />Dimensions (W x H x D [mm]) <br />250 x 170 x 28 <br />Weight (kg) <br />2.6 <br />Enclosure rating <br />Outdoor-NEMA 6 (IP67) <br />Cooling <br />Natural convection - No fans <br />Features <br />Communication <br />2.4 GHz Proprietary RF (Nordic) <br />Type of isolation <br />Galvanically Isolated HE Transformer <br />Monitoring <br />S-Miles Cloud' <br />Warranty <br />Up to 25 years <br />Compliance <br />UL 1741, IEEE 1547, UL 1741 SA (240 Vac),UL 1741 SB, CA Rule 21 (240 Vac)", <br />CSA C22.2 No. 107.1-16, FCC Part 15B, FCC Part 15C <br />PV Rapid Shutdown <br />Conforms with NEC-2017 and NEC-2020 Article 690.12 <br />and CEC-2021 Sec 64-218 Rapid Shutdown of PV Systems <br />*1 Nominal voltage/frequency range can vary depending on local requirements. <br />*2 Refer to local requirements for exact number of microinverters per branch. <br />*3 Hoymiles Monitoring System <br />* The HM-80ONT microinverter complies with <br />both CA Rule 21 (240 Vac) and CA Rule 21 (208 Vac). <br />© 2024 Hoymiles Power Electronics Inc. All rights reserved <br />