Laserfiche WebLink
MICROINVERTERS SPECIFICATION PV MODULE RATING @ STC Rooftop conductor ampacities designed in compliance with 120% RULE C" <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-405M art.690.8,Tables 310.15(B)(1),310.15(C)(1),310.15(B)(2), V <br /> MICROINVERTER MODEL NO. DS3-L 310.16,Chapter 9 Table 4,5,&9.Location specific BUS BAR RATING X 120%)- MAN BREAKER RATING <br /> MAX.POW POINT CURRENT(IMP) 13.03 AMPS temperature obtained from ASHRAE 2017 data tables =/M X. PV O CPD infinity solar <br /> MAXIMUM AC OUTPUT 768 W <br /> MAX INPUT VOLTAGE 60 V MAX.POW ER-POINT VOLTAGE(VMP) 31.10 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 3.20 A OPEN-CIRCUIT VOLTAGE(VOC) 37.03 VOLTS RECORD LOW TEMP - 5°C (200A x 120%)- 200 = 40A 6405 E MILL PLAIN <br /> VANCOUVER W A98661 <br /> MAX OUTPUT VOLTAGE 240 V SHORT-CIRCUIT CURRENTISC AMBIENT TEMP(HIGH TEMP 2%) 26°C PHONE:1-800-818-0598 <br /> ( ) 13.77 AMPS INFINITY SOLAR.COM <br /> NOM.MAX.POW ER AT STC(PMAX) 405 W ATT MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE 7 l8" THIS PANEL IS FED BY MULTIPLE SOURCES <br /> MODULE: ( 26) ZNSHINESOLAR ZXM7-SH108-405M (UTILITY AND SOLAR) REVISIONS <br /> INVERTER: ( 13)AP SYSTEMS DS3-L MAX.SYSTEM VOLTAGE 1500V ROOFTOP TEMP 4 s°c <br /> CONDUCTOR TEMPERATURE RATE 9 0°C Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C AC OUTPUT CURRENT 42A Initial Design 3/21/24 00 <br /> (26)ZNSHINESOLAR ZXM7-SH108-405M VISIBLE, LOCKABLE, LABELED DISCONNECT NOTE: (SOLAR PV SYSTEM EQUIPPED W TH III <br /> NOMINAL AC VOLTAGE 240V <br /> (13)AP SYSTEMS DS3-L INVERTERS W THIN 10'OF UTILITY METER RAPID SHUTDOW N NEEDS TO BE LOCATED POINT OF INTERCONNECT,SUPPLY SIDE <br /> W THIN 3FT OF AC DISCONNECT. EXISTING 240V/200A BUS BAR RATING, <br /> BRANCH 1 -10 MODULES W TH 05 MICRO INVERTERS Signature with Seal <br /> MAIN SERVICE PANEL,SINGLE PHASE, <br /> NOTE : W TH A 200A MAIN BREAKER <br /> ATTIC RUN -YES UTILITY COMPANY-SNOHOMISH CO.PUD <br /> SHUTDOW N- NO UTILITY METER#913588 <br /> EXISTING <br /> BI-DIRECTIONAL <br /> L — J L — J L — J L — J L — J <br /> (N)125A COMBINER PANEL, (N)BLADE TYPE M UTILITY METER, <br /> N 240V,3W 1-PHASE FUSIBLE AC DISCONNECTLINE SIDE TAP 1-PHASE,3W, Pro'ectName& <br /> -------------------- ------� NEMA 3R 60A-2P 120/240VAC USING IPC 120V/240V 1 <br /> Address <br /> BRANCH 2-08 MODULES W TH 04 MICRO INVERTERS <br /> (VISIBLE,LOCKABLE,LABELED) <br /> 60A FUSES E w-{ <br /> (N)JUNCTION BOX 200A z <br /> 600 V, NEMA 4 20A (E)LOADS LU <br /> UL LISTED � 0 0 <br /> L _ J L _ J L — J L — J W ~ rn Q <br /> 20A C/) 0", <br /> L1 L1 z <br /> (E)LOADS <br /> L2 L2 L1 �� O rn LU J <br /> BRANCH 3-08 MODULES W TH 04 MICRO MICROINVERTERS L1 L1 20A L2 0 N W zo < <br /> L2 L2 �t� Q N LU Lo 01� a W <br /> L1 uF G N N z w <br /> L2 L2 r--- ----- --- ------- — ------ - Q <br /> ---- -- �— -- — ----- — c C' G m <br /> L — J L — J L — J L — J �� J <br /> I —1- <br /> 1 �� � � EXISTING GROUNDING Sheet Name <br /> ELECTRODE SYSTEM <br /> 3-LINE <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CO NT. CURR WIRE TEM P CO NDUIT WIRE DERATED MAX. CO NT. LENG 7H VO LTAG E DIAGRAM <br /> TAG# DEVICES RATING M ULT CURR X 125% WIRE SIZE\TYPE\AM P. O CP #C.C.C. CO NDUIT DE-RATE: I FILL: AM P AM PACITY CURRENT G ND FT. MAX DRO F(%) <br /> Sheet Size <br /> #10\THWN\40A @90°C 20A 2 TRUNK CABLE 1.00 x x 1.00 40A 40.00A ANSI B <br /> O 05 x 3.20 x N/A = 16.00A 20.00A IN AIR 16.00A #6 AWG 20 0.28 <br /> 11" X 17" <br /> Sheet Number <br /> O05 x 3.20 x N/A = 16.00A 20.00A #10\THWN\40A @90°C 20A 6 3/4" EMT 1.00 x x 0.80 40A 32.00A 16.00A #8 AWG 35 0.48 E 1 .1 <br /> 1.10< <br /> 2 <br /> O13 x 3.20 x N/A = 41.60A 52.00A #6 \THWN\ 65A @75°C 60A 2 3/4" EMT 1.00 x x 1.00 65A 65.00A 41.60A #8 AWG 10 0.17 <br /> ® 13 x 3.20 x N/A = 41.60A 52.00A #6 \THWN\ 65A @75°C 60A 3 1 3/4" EMT 1.00 x x .00 65A 65.00A 41.60A #8 AWG 10 0.17 <br />