Laserfiche WebLink
PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SYSTEM LEGEND <br /> SYSTEM SIZE: 10.530 kW DC BILL OF MATERIALS0 <br /> 9.984 kW AC NUMBER OF MODULES 26 ZNSHINESOLAR ZXM7-SH108-405M EXISTING EXTERIOR MAIN SERVICE PANEL&POINT <br /> MODULE TYPE&AMOUNT: (26)ZNSHINESOLAR ZXM7-SH108-405M NUMBER OF INVERTER 13 AP SYSTEMS DS3-L �M OF INTERCONNECTION.TIED TO EXTERIOR UTILITY infinity s❑I❑r <br /> METER#913588. <br /> MODULE DIMENSIONS: (L/W/H)67.87"/44.64"/1.8" PV METER 1 125A PHOTOVOLTAIC METER <br /> INVERTER: (13)AP SYSTEMS DS3-L EATON BR STYLE 1-INCH LOAD CENTER NFINITYHOMESPLAIN <br /> LUTIONS <br /> COMBINER PANEL 1 6405 E MILL <br /> AHJ: CITY OF EVERETT AC NEW VISIBLE,LOCKABLE,LABELED DISCONNECT <br /> 816L125RP � LOCATED WITHIN 10'FROM THE UTILITY METER VANCOUVER WA 98661 <br /> 2520 19TH ST AC DISCONNECT 1 60A FUSIBLE AC DISCONNECT,240V INFIIN TYSOLAR.COM8 <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT NUMBER OF ATTACHMENTS 58 GRASOL GS-10 RAIL ATTACHMENTS © NEW DEDICATED PV SYSTEM COMBINER PANEL. <br /> WITHIN 10' OF UTILITY METER FRONT OF HOUSE RAILS 14 GRASOL RACKING SYSTEM REVISIONS <br /> RAIL SPLICE 8 SPLICE KIT Description Date Rev <br /> NOTE : 26 NEW ZNSHINESOLAR ZXM7-SH108-405M MODULES Initial Design 3/21/24 00 <br /> ATTIC RUN-YES MID CLAMPS 44 MID CLAMPS/UFO WITH NEW(13)-AP SYSTEMS DS3-L INVERTERS. <br /> ATTIC FAN-NOEND CLAMPS 16 END CLAMPS/STOPPER SLEEVE <br /> SHUTDOWN-NO 36"FIRE GROUNDING LUG 8 GROUNDING LUG <br /> SETBACK =FIRE PATHWAY <br /> 36"FIRE MODULE, ARRAY WEIGHT (LOAD Signature with Seal <br /> SETBACK � E10 =ROOF OBSTRUCTIONS <br /> 36"FIRE SETBACK 36"FIRE SETBACK CALC'S) <br /> r� Number of Modules 26 • =ATTACHMENT POINTS <br /> --------------- — Module Weight 45.19 LBS <br /> 0 <br /> Total Module(Array)Weight 1174.94 LBS =RAFTER <br /> Number of Attachment point 58 <br /> Mounting System Weight 1.5 LBS --- =RACKING SYSTEM <br /> U (Per Module) Project Name& <br /> Mounting System Weight 87.00 LBS <br /> C? =ATTIC RUN Address <br /> F Total System Weight 1261.94 LBS <br /> Q (Module Weight+Mounting System Weight) <br /> U) <br /> Weight at Each Attachment Point 20.26 LBS � =CONDUIT ATTIC RUN JUNCTION BOX L U <br /> cfl W (Array Weight/Number of Attachment Point) U <br /> Module Area(67.87"x44.64") 21.04 Sq Ft w <br /> N F Total Array Area 547.03 Sq Ft o <br /> m U Distributed Load 2 22 Per j rn Q Q <br /> w n (Tota System Weight/Total Array Area) Sq Ft = Q Z z <br /> Z Total Roof Area 1357 Sq Ft O M �' LU J_ <br /> oLL LL Total Percentage or Roof Covered 40.31% p I-__ O Q <br /> � ,TntalArrayArea/Tota Root Area,`,°° ROOF SECTIONS Q N w w <br /> = w <br /> ROOF#o1 MODULE-14 z <br /> SLOPE-31° Q <br /> ❑ AZIMUTH-91' <br /> MATERIAL-COMPOSITE SHINGLE <br /> 0 o RAFTER SIZE&SPACING-2"X8"@ 24"O.C. <br /> -------------- -------------- ROOF#02 MODULE-12 <br /> SLOPE-31° <br /> AZIMUTH-271' Sheet Name <br /> `-?' -------------- -------------- MATERIAL-COMPOSITE SHINGLE <br /> RAFTER SIZE&SPACING-2"X8"@ 24"O.C. SITE PLAN <br /> 0 <br /> -------------- —————————— Sheet Size <br /> 36" I A K 36"FIRE SETBACK ANSI B <br /> O MJACIC11° x 1 z° <br /> N Sheet Number <br /> ��+"�°�mluiymilxniuu)wgmyx�r�� PV 1 . <br /> EXISTING EXTERIOR MAIN SERVICE PANEL NEW AC COMBINER PANEL � <br /> NOTE: (SOLAR PV SYSTEM EQUIPPED WITH &POINT OF INTERCONNECTION.TIED TO - <br /> RAPID SHUTDOWN) NEEDS TO BE LOCATED EXTERIOR UTILITY METER#913588 <br /> WITHIN 3FT OF AC DISCONNECT. CIRCUIT(S) <br /> NEW PV AC DISCONNECT GROUPED <br /> WITH SERVICE EQUIPMENT(VISIBLE, CIRCUIT#1 - 10 MODULES WITH 05 MICROINVERTERSg°��"^')„i <br /> SITE PLAN LOCKABLE,LABELED) CIRCUIT#2-08 MODULES WITH 04 MICROINVERTERS <br /> 1 <br /> PV 1.1 SCALE:1/8”-V-0" CIRCUIT#3-08 MODULES WITH 04 MICROINVERTERS <br />