Laserfiche WebLink
MICROINVERTERS SPECIFICATION PV MODULE RATING @ STC Rooftop conductor ampacities designed in compliance with 120% RULE <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-405M art.690.8,Tables 310.15(B)(1),310.15(C)(1),310.15(8)(2), V <br /> MICROINVERTER MODEL NO. DS3-L 310.16,Chapter 9 Table 4,5,&9.Location specific BUS BAR RATING X 120%) - MAIN BREAKER RATING <br /> MAX.POWER POINT CURRENT(IMP) 13.03 AMPS temperature obtained from ASHRAE 2017 data tables = MAX. PV OCPD infinity solar <br /> MAXIMUM AC OUTPUT 768 W <br /> MAX INPUT VOLTAGE 60 V MAX.POWER-POINT VOLTAGE(VMP) 31.10 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 3.20 A OPEN-CIRCUIT VOLTAGE(VOC) 37.03 VOLTS RECORD LOW TEMP 5°C (200A x 120%) - 200 = 40A 6405 E MILL PLAIN <br /> VANCOUVER WA 98661 <br /> MAX OUTPUT VOLTAGE 240 V SHORT-CIRCUIT CURRENTISC AMBIENT TEMP(HIGH TEMP 2%) 26°C PHONE:1-800-818-0598 <br /> ( ) 13.77 AMPS INFINITY SOLAR.COM <br /> NOM.MAX.POWER AT STC(PMAX) 405 WATT MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE 7/8" THIS PANEL IS FED BY MULTIPLE SOURCES <br /> MODULE: (26) ZNSHINESOLAR ZXM7-SH 1 08-405M (UTILITY AND SOLAR) REVISIONS <br /> INVERTER: (13)AP SYSTEMS DS3-L MAX.SYSTEM VOLTAGE 1500V ROOF TOP TEMP 46°c <br /> CONDUCTOR TEMPERATURE RATE 90°C Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C AC OUTPUT CURRENT 42A Initial Design 3/21/24 00 <br /> (26)ZNSHINESOLAR ZXM7-SH108-405M VISIBLE, LOCKABLE, LABELED DISCONNECT NOTE: (SOLAR PV SYSTEM EQUIPPED WITH III <br /> NOMINAL AC VOLTAGE 240V <br /> (13)AP SYSTEMS DS3-L INVERTERS WITHIN 10'OF UTILITY METER RAPID SHUTDOWN) NEEDS TO BE LOCATED POINT OF INTERCONNECT,SUPPLY SIDE <br /> WITHIN 3FT OF AC DISCONNECT. EXISTING 240V/200A BUS BAR RATING, <br /> BRANCH 1 -10 MODULES WITH 05 MICRO INVERTERS Signature with Seal <br /> MAIN SERVICE PANEL,SINGLE PHASE, <br /> NOTE : WITH A 200A MAIN BREAKER <br /> ATTIC RUN -YES UTILITY COMPANY-SNOHOMISH CO.PUD <br /> PPPI SHUTDOWN - NO UTILITY METER#913588 <br /> 7. EXISTING <br /> BI-DIRECTIONAL <br /> L <br /> (N)125A COMBINER PANEL, (N)BLADE TYPE M UTILITY METER, <br /> N 240V,3W,1-PHASE FUSIBLE AC DISCONNECTLINE SIDE TAP 1-PHASE,3W, Pro'ectName& <br /> -------------------- ------� NEMA 3R 60A-2P 120/240VAC USING IPC 120V/240V 1 <br /> Address <br /> BRANCH 2-08 MODULES WITH 04 MICRO INVERTERS (VISIBLE,LOCKABLE,LABELED) <br /> 60A FUSES E W-{ <br /> (N)JUNCTION BOX 200A z <br /> 600 V, NEMA 4 120A (E)LOADS W <br /> UL LISTED � 0 0 <br /> L J L J L J L J W ~ rn Q <br /> L1 L1 = Q(E)LOADS z 'L2 L2 L1 �� O W JBRANCH 3-08 MODULES WITH 04 MICRO MICROINVERTERS I Q o Z Q <br /> L1 L1 L2 �� Q N W O <br /> L2 L2 Q N LU <br /> W <br /> L1 L1 G N N z w <br /> =L2 --- ----- --- ------- — ------ Q <br /> — — ----- — c C' G m <br /> L — J L — J L — J L — J J <br /> 1 '+ EXISTING GROUNDING Sheet Name <br /> ELECTRODE SYSTEM <br /> 3-LINE <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE DIAGRAM <br /> TAG# DEVICES RATING MULT CURR X 125% WIRE SIZE\TYPE\AMP. OCP #C.C.C. CONDUIT DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(%) <br /> Sheet Size <br /> #10\THWN \40A @90°C 20A 2 TRUNK CABLE 1.00 x 1.00 x 40A 40.00A ANSI B <br /> O 05 x 3.20 x N/A = 16.00A 20.00A IN AIR 16.00A #6 AWG 20 0.28 <br /> 11" X 17" <br /> Sheet Number <br /> O05 x 3.20 x N/A = 16.00A 20.00A #10\THWN \40A @90°C 20A 6 3/4" EMT 1.00 x 0.80 x 40A 32.00A 16.00A #8 AWG 35 0.48 E 1 .1 <br /> 1.10< <br /> 2 <br /> O13 x 3.20 x N/A = 41.60A 52.00A #6 \THWN \ 65A @75°C 60A 2 3/4" EMT 1.00 x 1.00 x 65A 65.00A 41.60A #8 AWG 10 0.17 <br /> ® 13 x 3.20 x N/A = 41.60A 52.00A #6 \THWN \ 65A @75°C 60A 3 3/4" EMT 1.00 x 1.00 x 65A 65.00A 41.60A #8 AWG 10 0.17 <br />