• • <br /> Pole Footing Embedded in Soil Project File:Amarok CA(95 mph).ec6 <br /> LIC#:KW-06014943,Build:20.22.8.17 FDR ENGINEERS,PLLC (c)ENERCALC INC 1983-2022 <br /> DESCRIPTION: 18"Dia. Perimeter Fence Steel Pole Foundation <br /> Code References <br /> Calculations per IBC 2018 1807.3, CBC 2019,ASCE 7-16 <br /> Load Combinations Used : ASCE 7-16 <br /> General Information <br /> Pole Footing Shape Circular <br /> Pole Footing Diameter 18.0 in <br /> Calculate Min.Depth for Allowable Pressures <br /> No Lateral Restraint at Ground Surface <br /> Allow Passive 200.0 pcf <br /> Max Passive 1,500.0 psf <br /> Controlling Values <br /> Governing Load Combinatiom0.60W Point Load 9 <br /> Lateral Load 0.2646 k <br /> Moment 1.323 k-ft <br /> NO Ground Surface Restraint <br /> Pressures at 1/3 Depth <br /> Actual 256.888 psf Soil Surface No lateral restraint <br /> Allowable 257.987 psf <br /> Minimum Required Depth 3.875 ft <br /> Footing Base Area 1.767 ft^2 <br /> Maximum Soil Pressure 0.0 ksf <br /> Applied Loads <br /> Lateral Concentrated Load (k) Lateral Distributed Loads (kit Vertical Load (k) <br /> D:Dead Load k k/ft k <br /> Lr:Roof Live k k/ft k <br /> L:Live k k/ft k <br /> S:Snow k k/ft k <br /> W :Wind 0.4410 k k/ft k <br /> E:Earthquake k k/ft k <br /> H:Lateral Earth k k/ft k <br /> Load distance above TOP of Load above ground surface <br /> ground surface 5.0 ft 10.0 ft <br /> BOTTOM of Load above ground surface <br /> ft <br /> Load Combination Results <br /> Forces @ Ground Surface Required Pressure at 1/3 Depth Soil Increase <br /> Load Combination Loads-(k) Moments-(ft-k) Depth-(ft) Actual-(psf) Allow-(psf) Factor <br /> 0.000 0.000 0.13 0.0 0.0 1.000 <br /> +0.60W 0.265 1.323 3.88 256.9 258.0 1.000 <br /> +0.450W 0.198 0.992 3.50 230.1 230.9 1.000 <br />