My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2923 COLBY AVE 2024-10-24
>
Address Records
>
COLBY AVE
>
2923
>
2923 COLBY AVE 2024-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2024 1:15:37 PM
Creation date
6/24/2024 10:31:11 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2923
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
° I SE 1/4,SEC. 19, T.29 N.,R.05E., W.M. HewittAve <br /> i 4 4 <br /> SNOHOMISH COUNTY, WASHINGTON <br /> ° > <br /> 4 44 a <br /> 0 <br /> U <br /> 4 4 <br /> I a <br /> 4 4 <br /> I - 4 EX.WATER METER N <br /> ° 4 \ <br /> 4 ° 4 CIN TDO A a" w E VICINITY MAP <br /> TAPPIN TEE, N N " SCALE: 1"= 10' SCALE r-2000 <br /> CONTRACTOR TO <br /> ° RUN A h DI PIPE. E 4 10 5 0 10 20 <br /> Permit#: PW2304-013 <br /> ° EX.BUILDING Site Address: 2923 Colby <br /> 4 4 ° 0 2923 COLBY AVE. Owner: Boyle Investment LLC <br /> Application Date: 04/17/2023 <br /> Q - LEGEND Description: Site Work for New Fire Service Line <br /> y <br /> ° 5o T <br /> EXISTING MONUMENT <br /> DL FH' J.T PPING TEE( ) ° (C) CALCULATED DATA <br /> (P) PLAT DATA 5-2.1 REQUIRED NOTES ON PLANS <br /> e (M) MEASURED DATA A.No connection to the existing mains will be allowed except by <br /> 4 /z� RE WATER METER means of an approved backflow <br /> of WATER DEPARTMENT ITO MAKE ALL URB AND EX.FIRE HYDRANT prevention device prior to satisfactory flushing,testing, <br /> CONNECTIONS TO LIVE WATER MAINS UNDER EX.LIG T POLE - FIRE DEPARTMENT CONNECTION AND <br /> SEPERATE UTILITY PERMIT.UTILITY PERMIT WILL TA WATER VALVE disinfection,and receipt DEWALK TO B POST INDICATOR VALVE TO BE pt of satisfactory <br /> °. BE BASED ON A COST ESTIMATE PREPARED BY EPLACED PMMOUNTED TO THE BUILDING GAS VALVE bacteriological test results. <br /> THE WATER DEPARTMENT AND PAID FOR BY THE <br /> OWNER/CONTRACTOR. TAIL 312 © POWER VAULT B.Connections to and taps on existing mains will be made by the <br /> Qo Un ITY POLE Public Works Department at the <br /> 2 PATCH ° DCDA PER COE STND.515 1 UTILITY ANCHOR developer's expense.The Public Works Department shall be <br /> 4 FI PAVE (UNLESS OTHERWISE FI given at least 5 business days notice <br /> ALLOWED IN THE ° TELEPHONE RISER for each connection.The Public Works Department shall <br /> SPRINKLER ROOM) x( LIGHT POLE thereafter determine the date and time <br /> ° q BLOW OFF at which the connection shall be made. <br /> 4 MAIL BOX C.All work and materials must conform to City of Everett <br /> m JUNCTION BOX Standards. <br /> STREET slcN D.A pre-construction meeting shall be held with the City prior to <br /> .� ^^J, "�'^'W'�'^'•^ IS <br /> STREET LIGHT <br /> the start of construction.The City <br /> EX.CB,TYPE I of Everett Public Works Construction Division must be notified at <br /> —® SAN SWR.MANHOLE least 24 hours prior to <br /> NaxoLRR%LUxe ° SS— SAN.SWR.PIPELINE commencement of construction. <br /> E.The developer or the developerOs authorized agent shall notify <br /> 4 — <br /> WATER PIPELINEthe Public Works Department of a <br /> -—-XXX-—-EX.CONTOUR <br /> person who can be contacted regarding problems during <br /> „�.m. p 9 9 p g <br /> ".. construction on a 24 hour basis. <br /> 'P '= ��^"" I � cENTERUNE F.Maintain a minimum of 10 feet horizontal and 18 inches <br /> � ��� - vertical separation between potable and <br /> "__, ^oM xx PROPOSED CONTOUR non-potable conveyance systems. <br /> �.� "�• � ..DN...m.. ° -a PROPOSED STORM DRAINAGE G.All City of Everett valves shall be operated by Public Works <br /> _ Psio 4 ---------"PROPOSED SEWER Department personnel only.All valves, <br /> Rm EaLaLc B <br /> --*.PROPOSED SEWER FORCE MAIN new and existing,shall be accessible at all times. <br /> R C EVERETT=" PROPOSED WATER MAIN.1nRE HYDRANT <br /> I �• Y„ � }L-”^•.••"" ,'V•",,•", O V "NO PARKING"SIGN <br /> ENGINEER <br /> INSIGHT ENGINEW oomw <br /> P.O.BOX 1478 <br /> EVERETT,WA 98206 <br /> _ PARTS NOTES NOTES CONTACT:BRIAN R.KAIAB,RE. <br /> xIR L10BLL OE. DST INDICATOR VALVE(MO PNNLED REDwnN TAMPERTO HRE ALARM PANEL 1. THE AND E.WTEVNVER-1 ED°NMAIN. FINALl01NTMUST PH:(425)303-9363 <br /> 18"K18')IB" AND WITH STENCILED ADDRESS NMI TE,1'HIGHTE%TI. BE SAWCIR 1. ALL TRENCHES IN ROADWAY ARM SHALL BE EMAIL:INFOOINSIGHTENGINEERING.NET <br /> CONI BIOOf E. K�NGLOVEO BACKFLOW PREVENTION E%ISTING CEMENT AS HATCHIXISTING CT'KFIRUNDANENGIN <br /> NEER PATCHED WITH TEMPORARY <br /> 2. DUCTILE IRO"PIPE ISRED AS REQUIREDI CIA5561. DEVICES. TING ASPHALT ASPHALT ATTHE END OF EACH WORK DAY,UNIFSS <br /> 3. <br /> SCHEDULE ADGALN.STEEL.RAPPEDWAMILPUSTIC. 3. ATSEMINSTAWBLYREQTIONUIRES <br /> RELETIRICAUT°IONUPON <br /> CONCRETE TEITH'OR ESS GRANTED TOGOOTHERWISEBYTHE CONTACT <br /> CIATT SI DI TEE FL%FL ANNUALLY BY OWNER. CONCRETE AM CLAW <br /> 2812 ARCHITECTURE <br /> @S. SWINGCHEM <br /> TIMENTVALVE W/GALL NIPASSEMBLY. A. ALL resrc6CD MUST HAVE BRAssPw6s. NG CONCRETE 1 E PH:(425)252-2153 <br /> fIRFOEDGAEANTCONN EL PIPE TO <br /> O B BRASS.DRED.SKNOXENCI LOCKING ADDRESS <br /> WHITE, 5. ROUND MANHOLE LIDS ARE NOT TO BE USED. T=FFCOMPLETION OFAWORK WITHIN ROAOWAYARFA. <br /> POSED6ALVON MI STEEL PIPE T°BF PLANTED RFD.STFN[ILADDRESS(WH TE <br /> —B B ]'HIGH TEKI)ON PLANTED PIPE. INSIDE DEPTH I5 TO BE KEPT AT AAM�MUM MINGMATCH E%ST NG THICKNESS° 3. CEMEHTCONUETE FDRPATCHING SHALL BE PT AAT AFIPROVED <br /> Ol. ALL PIPE THROUGH VAULT WALL SXALL Bf CORE DRILLED AHDXAVEA'UNKSEAL' & ASP 6MINCRUSHED SURFACING TOP COURSE COMMERCIALMI%0.S CNLECID .SOOT LtilY ti! YL,II <br /> TO (OR APPROVED EQUAL). ANO/OR AT APVIROVFD BYCT'OF EVEREST STANDARD SPECIFICATIONS. <br /> WILDING CS&Y VALVES.OHTAMPERSWITCHWAIARMMNELORCRAINATIDPADLOCK. T UTILITIES DEPABE RTMENT. SEE STANDARD DRAWING 616 <br /> 9. 1lWLV.IADDERWTIHPULL-UPLADDERE%TENSIONTOBESERMOTOVAULT METER gHA�LLWITH ACCESS HATCHSUCH OPEHAT IT <br /> LOORAx6rov&uLT wu��MDuxTEO wcH THAT u°Df&IS DRErnrABOVE BE <br /> ENTERING TI"EVAV OVEN EXISTING ASPHALT CONCRETE OVER CEMENT CONCRETE EV <br /> MFEWEOF ACCESSOPENINGFOR EASE OFACCESS. AND PUBLIC SERVICES DATE <br /> A TAMPER A 10 UL-FM USTED SOMEATED WA STATE APPROVED DOUBLE CHECK DETECTOR B. ALL DIMENSIONS ARE MINIMUM CLEARANCE. PUBLIC WORKS <br /> SWITOI IF VALVEATSEMBLY INCIUDING]-0.5.&Y RESMEMSEATEDGATF VAl1E5.TEST 9. ALLBACKFLOW DEVICES WILL BE INSTALUO <br /> L—————J REQUIRED COCI6.3/A'BRA55OR COPPER BYPASSWOH INUNEVALVES,S/B"%3 A• IxA DEPARTMENT <br /> 0—WE.OF W/E{ODER R9001,CU P,./STUB ANTENNA&A3/4 DOUBLE V ULT QUTRDETHEBUILOINGUNLE55 FINAL JOINT MUST UTILITIES DRAINAGE <br /> CHECK VALVE AST EM_ OTHERWISE APPROVED BY UTILITIES A PUBLIC WORKS PERMIT 15 REQUIRED PRIOR <br /> TUVERINTENOFNT. ETEH3'MIN) <br /> PLAN ]1 STATE APPROVED DOUBLE CHECK DETECTOR ASSEMBLY. E%ISTING ASPHALT TO STARTING ANY CONSTRUCTION ON THIS <br /> W.FIRE SFRVKE NPIxGS FROM MAIx TO CONCRETE 1 rxKKERrx&x PREWou51Y E%ISTEo CITY ENGINEER PROJECT APPROVAL FOR THIS PROJECT IS <br /> Q ICA(RESTRMIEDFu"GECOUPUN°AOArtERI. BUILDING SHALL BE RESTRNNED. CONDITIONAL PER CURRENT STANDARDS AND <br /> RAISED 3 0 <br /> LFTTfM 13 CUTABLE PADLOCK WITH KEY IN KNON BOX. ll.VROWSIONS FOR DRAINAGE OF THE VAULT EXPIRES______ UNLESS <br /> 'AUTO TMFPER $HALLBE INTHE FOLLOWING ORDER OF <br /> `T SPRINKUR' SWDCH IF DE-1/1'FEMALE FIREDEPT VRECEDENCE 6'rnlry 6'MINCRLSHEDSURRACING <br /> REQUIRED $ IN ETCONNECIONBRA55(NOT A)VAULT BRAIN TO DAYLIGHT TOP COURSE PERMIT F R N TR TI N N I <br /> PNNTEM-AUTOSPRINKLER' BI VAULT DRAIN TO STORM DRAIN SYSTEM <br /> WT-PE. ,� BE PRACTICAL) SEESTANDARDDRAWINGG3A <br /> 13%]HM• SCHEDUUEQGMANGEDSTEEL QINENINOSSIBLEMEANSOFGRANITYDRNN, City of Everett Permit Review <br /> STENCILED CONI B&A PAINTED RED STENCILED ADDRESS STALL SUMP PUMP <br /> AODRESSTO EVERETT Status:Approved as Noted <br /> FACE SIREFT PAINTEDWHITE , SWINGVALVELINEMUST EXISTING ASPHALT CONCRETE OVER PREPARED GRADE .1.1 'INCAVAULT.�F°UTSIMOFDCDA <br /> uHEDULEAoULT,MUSTBE IN MINIMUM VXA'VAULT.GALVANQEDSTEEL 13.PIV LOCATION MUST BE DOWNSTREAM OF <br /> PED WITH I DCDA AND UPSTREAM OF FOC. MUSTMIL PLASTIC 1 NEW YO MUST BE LOCATEDV IN75'OFA 9EMCUII FIRE OR1arFORANE%ImW %ISTING CE ENT ExB.MIEINSIGHT ENGINEERING CO. <br /> sBUILDING BEING RETROFIT FOR SPRINKIERS). B CONCRETE 1 THICKER THAN PREVIOUSLY EXISTED <br /> L'l NEW FIRE HYDRANT INSTALIAEON MAYBE PAVEMENT3NEEOFD TO MEET GOOF REQVIREMENi P.O.BOX-1478 <br /> EVERETT,WA 98206 <br /> PILE WHEN HRE RDDM I5 Mo E T"""o'F"DM MNN (425)303-9363 (425)303-9362 FAX <br /> PROVIDE V MINIMUM AND II'MA%IMUM EVERETT R INELI.WORKf a •Mlxcxus SURFACING CITY OF EVERETT INFO@INSIGHTENGINEERING.NET <br /> CLEARANCEBETWEENVA—FLOOR ANDBOTTOM WASHINGTON DEPARTMENT 6'MIN TOP COURSE PUBLIC <br /> PUBLIC WORKS DEPARTMENT <br /> BACKFLowA55EMelY.WHERE ELEVATION OF �, s 1� SEE STANDARD DRAWING Gla +_^ o""7z672o1T SITE ADDRESS: 2923 COLBY AVE <br /> rosmVEVAULTDFMN VA%TFLDDRDTDDL0wT0DRAINTDDAYu6HT 37?)imD <br /> ORSTORMOREPAI,MGEtAPPR VED DOUBLE CHECK DETECTOR EXISTING CEMENT CONCRETE OVER PREPARED G RADE EVERER,WA 98201 <br /> 1, DCOVA ELEVATION A-A OPENINGfOR DRAINAGE)APPROVED BVMf OTY FDC ELEVATION B-E VALVE ASSEMBLY W/FDC&PIV I. PAVEMENT PATCHING DETAILS 326 <br /> KNOW WI1Br5 beIOW. ENGINEFRONAUTE BY CATS BASK ONLY). (DCDAI I'&IARGFRSERVICE 515 TAX ACCOUNT NO.'S: 00644 9 683009 00 <br /> Call before you dig. REV.N0, DESCRIPTION INITIALS DATE <br /> VTIL17T CONFLICTNOTE: (:T)DOUBLE CHECK DETECTOR VAL VE ASSEMBLY W/FDC&PIV DETAILPAVEMENT PATCHING DETAIL <br /> F1 NOT TO SCALE STD.DTL.515 �FVNOT TO SCALE STD.DTL 32670 SCALE STD.DTL 326 R <br /> CAUTION.' Q of N^sq y SE 114,SEC.19,T.29 N.,R.05 E.,W.M <br /> THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION 'tib@ V�c� <br /> DIMENSION,AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE _ IRISHMEN PUB <br /> PLANS OR NOT,BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL r � 9 <br /> fD h <br /> AND VERTICAL LOCATION PRIOR TO CONSTRUCTION.THIS SHALL INCLUDE <br /> CALLING UTILITY LOCATE®7-800-424-5555 POTHOLING ALL OF THE EXISTING � DWG FILENAME DESIGNED BY: DATE: SCALE: JOB NO.: <br /> UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY 6` 36499 <br /> "ETHER 221221-PRELIM.DWC JTK 08-25-2022 1"=10' 22-1222 <br /> THER OR NOT CONFLICTS EXIST LOCATIONS OF SAID UTILITIES AS SHOWN FS C/STB�Gti <br /> ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND SIGNAL SHEET <br /> ARE SUBJECT TO VARIATION.IF CONFLICTS SHOULD OCCUR,THE CONTRACTOR <br /> CONSULT WITH <br /> PROBLEMS PRIORTO PROCEEDING WITHCONSTRUCTION, IRISHMENPUB <br /> RESOLVE ALL 08/30/2022 FIRE LINE CONNECTION F1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.