(E) POTTER i PA-1 00 <br /> The Symbol of Protection Fire Alarm Control Panel <br /> SLC Loop Accessories <br /> The control panel may be connected with up to 127 addressable devices or modules in any combination.The SLC is not restricted by any special wire <br /> requirements and may be wired with any wire that complies with the NEC. <br /> SLC Loop Devices <br /> Device Description Ad <br /> PAD200-PD Analog Photoelectric Smoke Detector is a smoke detector with a listed obscuration of 1.0 to 3.70/o/foot.UL 268 7th Edition. <br /> PAD200-PHD Combination Analog Photoelectric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.0 to 3.5%/foot <br /> obscuration and a fixed temperature range of 135°F to 185°F heat detector.Smoke detection compliant with UL 268 7th Edition. <br /> PAD200-PCD Combination Photoelectric Smoke/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Carbon <br /> Monoxide detection compliant with UL 2075. <br /> Combination Photoelectric Smoke/Heat/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Heat <br /> PAD200-PCHD detection with a fixed temperature range of 135°to 185°F and is UL 268 and UL 521 7th Edition compliant. Carbon Monoxide <br /> detection compliant with UL 2075. <br /> PAD100-HD Analog Fixed Temperature(135°-185°F)or Rate-of-Rise Heat Detector(software selectable). <br /> PAD200-DUCTR Addressable Duct Smoke Detector with Form C Relay rate at 1OAmps @ 250/120VAC or 8 Amps at 30VDC. <br /> PAD200-DUCT Addressable Duct Smoke Detector. <br /> PAD 100-6B 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors. <br /> PAD 100-4B 4"round base that may be mounted to an electrical box and wired for connection to the above sensors. <br /> PAD100-I13 Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. <br /> PAD100-RB Addressable Relay Base that contains one relay controlled by the SLC.Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. <br /> PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call. <br /> PAD100-CD Addressable CO gas detector. <br /> PAD 100-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure. <br /> PAD100-LFSB Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local,group and all <br /> call. The LFSB complies with the Low Frequency Signal Requirements(520 Hz) <br /> PAD100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830101-REV H 2/22 PAGE 2 OF 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.